Symptoms

Checkups

Actions

In case that the 

wind doesn't 

come out even 

after you insert 

your hands

In case of 

making severe 

noise and 

strange sound

In case that the 

wind smells bad

In case that 

water is dripping 

to the floor

In case that 

the wind 

doesn't stop

In case that the 

self-diagnosis

 lamp is

flickering

If the problem remains even after the above actions are taken, contact the store that you 

purchased the machine or our repair & service center after turning off the power.

-Is there any power failure?
-Is the power cable unplugged?

-Is the power 230V?
-Are your hands sufficiently inserted?
-Is the operational indication original 
 ramp all coming to light?

-Isn't the wall where the machine is 
-installed weak or isn't the machine
 unstably installed?
-Is any stuff placed on the back side
 of the product or on the machine?
-Isn't the fixing board contacted 
 with the wall?

-Isn't the water receiver full with
 water?

-Is the water receiver properly 
 inserted?
-Is the water spilling over from the 
 water receiver?

-Isn't there any foreign substance 
 or pollutant on the sensor?

-Dose the filter lamp lighting up 
 green?
-Isn't the motor running with the 
 motor lamp lighting up red?
-Does the water level lamp light up 
 green?

-Empty the water receiver and clean it.

-Insert the water receiver properly.

-Remove the water from the water
 receiver.

-Turn the power off and clean the sensor 
 part and then turn the power on.

-To shift the filter where becomes the 
  filter shift time.
-There is a problem on the heater and 
 contact the repair & service center.
-Remove the water from the water 
 receiver.

-Install the machine on a solid and flat 
 wall.

-Remove the stuff.

-Fix the fixing board in the wall so it 
 wouldn't shake.

-Check the power state of other product.
-It makes the power plug paste in the cone 
  cent, to connect.
-Connect into 230V power supply.
-Insert your hands into the vent correctly.
-Turn the power off and clean the sensor 
 part and then turn the power on.

9. Trouble Shooting

Insertion-type Hi-speed Hand Dryer

Summary of Contents for TH1500DB

Page 1: ...Finished Installation Cautions in Installation Installation Method How to Use How to Clean Trouble Shooting Specifications Warranty 1 1 2 2 3 3 4 4 5 5 7 7 8 8 9 9 10 10 6 6 Please read through the manual for appropriate use of the product After you read through the manual keep it in a proper place for the users ...

Page 2: ... shock hazard Make sure to keep the plug out while you are cleaning If you don t so electric shocks may possibly occur Never spray cleanser on the main body or the power cable part There are fire hazard and electric shock hazard Do not put the electric cable in or pull it out with a wet hand If you do so electric shocks may possibly occur Do not insert the plug into the shaking or worn out socket ...

Page 3: ...nds into the air vent To prevent children s mischief or continuous running by the sensing error of the sensor the machine is designed to be stopped about 20 seconds after continuous running You can reuse it by pull the hands out and then put them in again The built in water receiver is removable slide therefore anyone can easily remove the water that is full in the receiver Do not lean on or hang ...

Page 4: ...ing water into face or body the machine is sanitary This machine is sanitary with its antibacterial intake antibacterial filter and separate structure of air intake With the application of antibacterial resin to the injection molding material in the region where bacteria may breed the machine is sanitary There will be an own diagnostic feature and the case operational indication original LED ramp ...

Page 5: ...Part Front Case Water Receiver Bracket Brush Bracket fixing Bolts User Manual Mounting surface Guiding Sheet Power Cable Operation manipulating Part Operation indicating Window If you turn the volume clockwise the machine releases the strong wind speed If you turn the volume counterclockwise the machine release the weak wind speed Accessories 3 Name of Each Part Wind speed Adjusting Volume Power S...

Page 6: ...er If you don t so fire or electric shock may possibly occur 4 Drawing of Finished Installation 5 Cautions in Installation Thank you very much for purchasing our product Install the machine correctly following this manual so it can perform well This indication means that the person can be seriously injured or even dead if he or she uses the machine improperly ignoring this indication In case of ne...

Page 7: ...o the separation of the machine The rated power consumption of the machine with AC 230V and 50 60Hz is 1330W Make sure to install the appropriate wiring according to the above Use a single phase alternating current 230V If you use 110V the machine cannot be operated 1 Fixation of Installation Plate Consideration for installation environment Install the wiring correctly following the regulation for...

Page 8: ...e space of 320mm in height from a floor which is the recommendation installation height Make sure to install the machine so the distance from the wall is more than 10mm The wall where the machine is to be installed should be flat without any layers Avoid the place for installation where people bump into the machine easily and doors contacts it Do not turn the power switch on after inserting your h...

Page 9: ...motor output decreases It will be able to economize an electricity If you spin the wind speed adjusting volume clockwise of the operation manipulating part located on the right middle of the main body the wind becomes strong And if you spin it counterclockwise the wind becomes weak You can adjust the wind strength in 6 phases and the green LED lights up on one of the strong medium and weak lamps a...

Page 10: ...d and electric hazard Do not use toilet detergent house detergent benzene thinner cleanser and nylon scrubber when you clean the machine because they can damage plastics Sensor Part The contamination of the sensor part can cause poor sensing or malfunction Clean the machine regularly with a soft cloth Note Be careful not to make any flaws in the sensor part while you are cleaning it Remove the rem...

Page 11: ...tibacterial resin and the antibacterial filter After cleaning connect the filter into the intake of the antibacterial resin and then place it into the original location keeping the grip of the intake of the antibacterial resin downward Cleaning the filter with water or cleanser can cause the problem on the machine as the moisture flows into the inside of the main body In case of cleaning it with w...

Page 12: ...receiver full with water Is the water receiver properly inserted Is the water spilling over from the water receiver Isn t there any foreign substance or pollutant on the sensor Dose the filter lamp lighting up green Isn t the motor running with the motor lamp lighting up red Does the water level lamp light up green Empty the water receiver and clean it Insert the water receiver properly Remove the...

Page 13: ...n must not assemble or repair the machine In that case there is an electric shock hazard Size Rated Power Rated Power Consumption Motor Filter Blast Fan Safety Device Cover Material Capacity of Water Receiver Wind Speed RPM Weight 300 W x 557 H x 194 D mm AC230V Usable for both 50Hz and 60Hz 1330W Brush Motor HEPA Filter Turbo Fan Temperature Fuse Overcurrent Fuse and Bimetal SW ABS Resin Heat res...

Page 14: ...Memo ...

Page 15: ...e of the followings you are charged for repairs This warranty cannot be reissued and keep it with care When requesting a repair make sure to present the warranty If you have any questions about the repair after expiration of warranty period etc please contact our repair service center Troubles or damages caused by carelessness in use and improper repair or remodeling Troubles or damages caused by ...

Page 16: ...www tsjava com ...

Reviews: