Gutter drainage
LEK
F2120
Frostfritt
djup
Frost free
depth
Water seal
Route the pipe downward from the heat pump.
The condensation water pipe must have a water seal to
prevent air circulation in the pipe.
Caution
If none of the recommended alternatives is
used good lead off of condensation water must
be assured.
Supplied components
JÄSPI Inverter Nordic-8,
JÄSPI Inverter Nordic-12
Filterball (G1").
LEK
LEK
2 x flexible pipes (DN25, G1")
with 4 x gaskets.
JÄSPI Inverter Nordic-16,
JÄSPI Inverter Nordic-20
Filterball (G1 1/4").
LEK
LEK
2 x flexible pipes (DN25, G1
1/4") with 4 x gaskets.
JÄSPI Inverter Nordic
Chapter 2 |
Delivery and handling
12