OPERATION INSTRUCTIONS
Lighting up of Appliance with separate pilot and flame failure valves:
1. Check that you've switched on the isolating gas cock. The isolating valves 1 to
each product are on the wirings underneath the item.
2. Check whether the main stove gas valve handle is in the OFF situation.
3. Turn the status of the black knob labelled pilot to ON.
4. Press the flame failure switch strongly. Once done, hold it for almost 20 seconds
while using a taper or gas match to the pilot light beside the main stove. When
you've established the pilot, release the button pressure. (Kindly Note) On new
setups, you need 2 or 3 attempts until the air in the pipes is disseminated.
5. Move the gas valve switch status to "ON", as mentioned on the panel, to switch
the main burner on.
6. To turn off the device, rotate the pilot knob to the "OFF" status. Besides, confirm
that the "ON, OFF" main gas valve lever is in the "OFF" status.