background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 6 of 8

  

 

 

Customer Service :  800.255.5766 

user MaInTenanCe InsTruCTIOns

huMIDITY

Warning:  avoid high humidity levels in your home. mold, mildew, 

fungi, and bacteria which may be harmful to health thrive in areas with 

continued high humidity levels; therefore, every precaution should 

be taken to make sure your plumbing fixtures including bathtubs, 

therapy baths, or showers do not become a source of high humidity 

due to improper installations or leaks.

To avoid having your plumbing fixtures become a source of 

unwanted humidity, please make sure the following steps 

are taken prior to installation.
1. Make  sure  the  area  where  the  bathtub  or  shower  is 

installed is well vented and allows enough ventilation and 

air circulation to dry the bathroom environment within a 

short time after taking a bath or shower.

2. If your bath or shower unit is tiled-in, use units with an 

integral tile flange or make sure a tile flange kit or a similar 

mechanical barrier is installed to prevent shower spray, 

splash, or overflow to leak behind the bathtub. 

3. Make sure the plumber properly tests the AirMasseur

®

 bath 

before it is roughed in to make sure there are no leaks and 

it is installed with proper access to bath equipment.

4.  Make  sure  that  all  of  the  plumbing  and  fixtures  in  the 

bathroom are in good working order and have no leaks.

5.  Do not use carpeting or other materials or furniture, which 

can hold moisture, in your bathroom.

6. Use disinfectant to clean any bathroom surfaces, which 

are regularly exposed to moisture.

7.  Clean  and  disinfect  humidifier  and  dehumidifiers  as 

recommended by the manufacturer.  Replace the air filter 

on the HVAC unit once a month.   

8. Clean moldy surfaces as soon as any mold appears by 

using a detergent/soapy solution and appropriate household 

cleaner. Always use gloves during cleaning.  Dispose of 

any sponges or rags used to clean mold.

CleanInG

With minimum care, this acrylic-surfaced bath will retain its 

high-luster finish for many years. For regular cleaning use 

Jason Bath Cleaner or a mild NONABRASIVE

 

liquid detergent 

solution (i.e. glass cleaner) and a soft, wet cloth or sponge.  

Do not run the air system with foaming cleaners or soaps. 

Rinse the bath thoroughly after cleaning.

aIr heaTer anD aIr TeMPeraTure

The air heater incorporated into the air blower is designed 

to preheat the incoming air to body temperature, not to heat 

the bath water. The air heater automatically turns on when 

the air blower is activated. 
Even through all Jason Integrity

TM

 AirMasseur

®  

baths provide  

preheated air, occasionally some people with sensitive skin 

might experience a cold air sensation. This sensation is caused 

by the swiftly moving heated air bubbles blowing on the wet 

skin. This phenomenon can be related to the use of a fan for 

cooling on a hot day. While the ambient temperature does 

not change, the moving air makes you feel cooler. Avoiding 

this cold air sensation is among the reasons Jason avoids 

placing air jets directly beneath the body. If you experience 

a cool air sensation, which is most noticeable during the first 

few minutes of an air bath, simply move your body slightly 

away from the closest air jets.

FlushInG / sanITIZInG

Upon  start-up  and  not  to  exceed  90  days  thereafter,  flush  the 

airmasseur

® 

bath and plumbing system with 

Jason’s Bath System 

Cleaner, available at Jason Dealers, or use an equivalent 

cleaner.  Follow the cleaning instructions below: 
1.  Close the bath drain.
2.  Fill the bath with warm water to a level at least ten inches 

below the bath deck.

3.  Pour 16 ounces of Jason’s Bath System Cleaner into the 

bath water.

4.  Turn on the blower for 10 minutes.
5.  Turn off the blower and drain the bath.

6.  To rinse, refill the bath with cold water, turn on the blower 

for five minutes, then turn off the blower and drain the 

bath.

Note:

 The bath can be sanitized after each bather without 

harming the AirMasseur

®  

bath plumbing.

aCrYlIC surFaCe MaInTenanCe

Areas  with  minor  scratches  or  dull  surfaces  can  be  

restored  by  applying  commercially  available  plastic  polish 

(i.e.  Novus  Plastic  Polish  No.  2,  available  at  your  Jason 

dealer), followed by an application of acrylic paste wax. Buff 

the surface with a clean soft cloth. 

CautION: Do not use sandpaper, steelwool, or abrasive rubbing 

compounds.

If  scratches  are  too  deep  to  rub  out,  or  if  the  damage 

penetrates  the  acrylic  surface,  consult  the  dealer  for  

recommendations on surface repair.

PluMBInG Or eleCTrICal rePaIr

Refer all plumbing or electrical repair to a qualified service 

technician. 

DO  NOt  attEmPt  tO  RESOlVE  thE  PROblEm. 

Attempts to repair plumbing or electrical equipment by a non-

qualified service technician can result in danger of electrical 

shock or damage to the unit and will 

VOID thE WaRRaNtY.

 

When contacting the dealer or service representative, always 

have the serial number, proof of purchase, and model number 

available.  This  will  insure  a  quick  response  on  warranty 

items. The serial number can be found on the front page of 

this manual or on the small card adhered to the back of the 

bath just above the blower.  

all WaRRaNtY REPaIRS muSt bE  

authORIzED bY thE maNufaCtuRER bEfORE WORK IS StaRtED.

Summary of Contents for Integrity AirMasseur B3260

Page 1: ... in transit is the responsibility of the carrier The owner or installer MUST open uncrate and inspect the unit for damage when it is delivered Inspect plumbing and whirlpool surface for missing or damaged components Alertthedealerofanydiscrepancies Ifdamage is discovered immediately notify the carrier in writing and request that they have a representative inspect the unit If the carrier fails to r...

Page 2: ...d install at this time 3 Level the bath and remove packing board a Install the bath level for proper drainage Jason baths are designed to be supported under the entire base of the bath If the floor is smooth and level the bath s Level Form base will provide proper drainage and support See Figure 3 Mortar is required when the subfloor is notsmoothandlevel whenadditionalsoundinsulation is desired or...

Page 3: ...ng any work Use 1 5 ABS or PVC plastic tubing Locatethecontrolboxwiththeblowerinanareaaccessible for servicing NOTE A 15 foot replacement air switch tube can be purchased from a Jason dealer if needed To insure proper functioning of the system avoid remote mounting in a location which requires more than six 6 piping direction changes A 90 direction change should be made up of two 45 elbows for max...

Page 4: ...ircuitInterrupter GFCI protected 120v volt 20A amp 60Hz hertz circuit with a service ground DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit Interrupter GFCI In the unlikely occurrence of a current imbalance in the power conductors the GFCI will interrupt the power to the bath INSTALLSERVICECONNECTIONATLEAST6 ABOVE THE SUB FLOOR The air switch control box...

Page 5: ...or a soaking bath Blower TheJasonIntegrityTM AirMasseur systemcontainsavariable speed controlled heated air blower The blower provided is factory tested when assembled onto the bath The blower must be plugged into the air switch control box which must be plugged into its dedicated GFCI electrical service prior to turning it on Air ON OFF BUTTON The Air On Off button air switch activator allows the...

Page 6: ...r is activated Even through all Jason IntegrityTM AirMasseur baths provide preheated air occasionally some people with sensitive skin mightexperienceacoldairsensation Thissensationiscaused by the swiftly moving heated air bubbles blowing on the wet skin This phenomenon can be related to the use of a fan for cooling on a hot day While the ambient temperature does not change the moving air makes you...

Page 7: ...turer or supplier To obtain warranty service you must contact the retailer from which the merchandise was purchased or Company s distributor in your area Written notice of warranty defects must be given to the company within thirty 30 days from the occurrence thereof Written permission must be obtained by the retailer or distributor from the Company before any equipment claimed defective is return...

Page 8: ...bathwhileundertheinfluenceofalcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using an AirMasseur bath G Persons using medication should consult a physician before using an AirMasseur...

Reviews: