GENERAL OPERATING INSTRUCTIONS
INTRODUCTION
This manual contains all of the information needed for the proper
installation and operation of your Jason Air-Whirlpool bath. The
Air-Whirlpool bath has been designed to give you years of
relaxing trouble-free service, provided the unit is maintained
and operated in accordance with these instructions.
Thoroughly clean and disinfect the unit as described in the
CleaNINg
section of the
user MaINTeNaNCe INsTruCTIONs
on
page 10 before its first use and periodically thereafter.
CAUTION
: Keep hair, towels, and clothing away from the suction
fitting whenever the Air-Whirlpool equipment is On. never
operate the equipment with the suction cover off, doing so voids
the manufacturer’s warranty--it is a safety cover designed to
eliminate the potential of hair and body entrapment.
All Jason Air-Whirlpool baths are pre-plumbed at the factory.
WARNING: Before operating refer to the instructions pertaining to the
risk of fire, electric shock, or injury to persons on page 12.
JETS
Strategically placed whirlpool jets are provided for complete
enjoyment of your bath. The jets are specially designed for
maximum whirlpool action with either directional or rotational
capabilities. By changing the direction of the jets, you can
concentrate the massaging jet stream to your area of preference.
You can also individually adjust the flow of each jet.
AIR VOLUME CONTROL
Two air controls are conveniently located for bather control.
Turning the knob counter clockwise increases the air flow
and turning the knob clockwise decreases the air flow. For
maximum whirlpool effect, open the air controls completely.
Restriction of the air controls will produce fewer air bubbles
and a reduction in hydrotherapy performance.
PUMP
Pumps provided on Jason Air-Whirlpool baths are factory
tested when assembled and retested after installation on
the Air-Whirlpool bath. These pumps are of efficient design
incorporating high quality long life seals which provide superior
service. However, should the pump need service, suction and
discharge unions are provided for easy pump removal.
FILLING AND DRAINING
Close the drain and fill the bath with water at least two (2)
inches above the jets. The inlet temperature should not exceed
40°C (104°F) as this could damage the acrylic surface.
When bath is in use, turn the unit Off before draining the water.
The bath unit and its plumbing are designed to drain after each
use whether used as an Air-Whirlpool bath, soaking bath, or
just taking a shower.
BLOWER
The blower generates warm air and pushes it through the air
jets. Blowers provided on Jason Air-Whirlpool baths are factory
tested when assembled and again retested after installation on
the Air-Whirlpool bath.
STANDARD EDITION AUTOMATIC PURGE
Fifteen minutes after the control has shut off and the bath is
completely drained, the blower will start again for a two-minute
purge cycle that dries the air channel. Note that the blower light
will flash during the 15-minute pause before the purge cycle
begins. Once the purge cycle begins, all indicators will light and
the keypad operation will be disabled for two (2) minutes.
SIGNATURE EDITION AUTOMATIC PURGE
Twenty (20) minutes after the control has shut off and the bath
is completely drained, the blower will start again for a two-
minute purge cycle that dries the air channel. Note that the LCD
display will read “PURGE” and begin to countdown the 10 or
20 minute pause before the purge cycle begins. The readout
will display “PURGE ON” during the purge cycle.
Any time during the pause before the purge cycle begins,
pressing and holding the Blower Speeds icon will reduce the
pause from 20 minutes to 10 minutes. During the two-minute
purge, pressing the “Blower On/Off” icon will stop the purge.
SIGNATURE EDITION DAILY PURGE
The daily purge can be activated through the customized
settings of the Signature Edition touchpad. When activated
the daily purge will start the blower for two-minutes at the
same time everyday to dry the air channel. See ‘Operating the
Signature Edition Air-Whirlpool Touchpad’ section on page 9
for details on activating this setting.
INITALIZATION OF SIGNATURE EDITION CONTROL
SYSTEM
The pump and blower junction box must be connected to its
dedicated service prior to filling the bath with water.
This will
assure the control box is properly initialized (see Figure 4A).
SIGNATURE EDITION UNIVERSAL REMOTE
CONTROL
In addition to the main control console installed on the bath
deck, a floating, waterproof Universal Remote Control is
provided with all Signature Edition Air-Whirlpools. This remote
control is capable of operating the same functions as the bath’s
main control console, plus the bather may remotely operate a
TV, DVD, CD, etc. Refer to the
Instruction Manual
provided with
the remote control for detailed instructions.
NOTE
: If the unit fails to operate, check the breaker panel to
insure that the circuit breaker is on. Check the GFCI by testing
and resetting it. Also check the water level in the bath; it must
be above the water level sensor located on the sidewall of the
bath for the pump to operate. If the unit still fails to operate, refer
to the Trouble Shooting Guide section of this manual. If the unit
still fails to operate and is out of warranty, contact an authorized
service technician for repair. If the unit is within the warranty
period, contact JASON Technical Service at 800-255-5766. DO
nOT ATTEMpT TO rESOLVE THE prOBLEM.