Jason International, Inc. •
501.771.4477
Page 9 of 18
Customer Service : 800.255.5766
Copyright © 2011 Jason International.
Jason’s Standard Edition MicroSilk-Whirlpool system fea-
tures the best in luxury bathing for the leisure bath industry.
To assure that your bath functions properly, the MicroSilk
and pump control boxes must be properly connected.
NOTE: For 120v systems, the power cord for the MicroSilk
control box must be plugged into a 120v, 20 amp GFCI
dedicated circuit. The power cord for the Whirlpool
control box must be plugged into a 120v, 20 amp GFCI
dedicated circuit (30 amp circuit if the optional heater
is installed).
The MICROSILK CONTROL
The MicroSilk unit and keypad must be plugged into the proper
receptacles for correct operation of the MicroSilk-Whirlpool
system. See
Figure 10
for connections: (F) 8-pin mini-DIN
terminal for the MicroSilk-Whirlpool keypad. (G) The power
cord for the MicroSilk control box must be connected into
the proper GFCI dedicated circuit for the system (see note
above). (I) The MicroSilk pump’s power cord will need to be
plugged into the control box (H). Refer to the
ELECTRICAL
section of this manual for connecting the pump to the control
box. (E) Six-pin mini-DIN terminal for optional LED light.
The PUMP CONTROL bOX
The Pump and Water Level/Vacuum Sensor must be plugged
into the proper receptacles for correct operation of the system.
See
Figure 10
for connections: (A) The power cord for the
pump control box must be plugged into a 120 or 240v, 20 amp,
GFCI dedicated circuit. (C) The pump’s power cord will need
to be plugged into the control box (B). (D) Two-pin terminal
for installation of the water sensor to the pump control box.
MICROSILK
TM
-WhIRLPOOL CONTROL bOX CONNeCTIONS
STANDARD eDITION MICROSILK
TM
-WhIRLPOOL
Figure 10
Jason’s Premier Edition MicroSilk-Whirlpool system
incorporates all the features of the Standard Edition
system and includes the benefits of a combination
pump/heater, ozone sanitation system, and an LED
Chromatherapy light. To assure that your bath functions
properly, the pump control box must be properly connected.
NOTE:
For 120v systems, the power cord for the Micro-
Silk control box must be plugged into a 120v, 20 amp
GFCI dedicated circuit. The power cord for the Whirlpool
control box must be plugged into a 120v, 20 amp GFCI
dedicated circuit (30 amp circuit if the optional heater
is installed).
The MICROSILK CONTROL
The MicroSilk unit and keypad must be plugged into the proper
receptacles for correct operation of the MicroSilk-Whirlpool
system. See
Figure 11
for connections: (F) 8-pin mini-DIN
terminal for the MicroSilk-Whirlpool keypad. (G) The power
cord for the MicroSilk control box must be connected into
the proper GFCI dedicated circuit for the system (see note
above). (I) The MicroSilk pump’s power cord will need to be
plugged into the control box (H). Refer to the
ELECTRICAL
section of this manual for connecting the pump to the control
box. (E) Six-pin mini-DIN terminal for LED light.
The PUMP CONTROL bOX
The Pump and Water Level/Vacuum Sensor must be
plugged into the proper receptacles for correct operation of
the system. See
Figure 11
for connections: (A) The power
cord for the pump control box must be plugged into a 120
or 240v, 20 amp, GFCI dedicated circuit. (C) The pump’s
power cord will need to be plugged into the control box (B).
(D) Two-pin terminal for installation of the water sensor to
the pump control box.
PReMIeR eDITION MICROSILK
TM
-WhIRLPOOL
STANDARD eDITION MICROSILK-WhIRLPOOL
PARTS LIST
MicroSilk Pump Unit
MicroSilk Control Box
Pump Control Box
Control Box Stand
Keypad
Keypad Cable
Pump
Water Level/Vacuum Sensor
NOTE: This diagram (Figure 10) also applies to 50 hz,
240v pumps, controls, and power supply systems. Except
that the MicroSilk and Whirlpool Pump junction boxes
must be connected into one dedicated 240v, 20 Amp
GFCI circuit.