background image

Jason International, Inc.  ·  501.771.4477                              Page 5 of 12                                              Customer Service: 800.255.5766 

Copyright © 2021 Jason International, Inc. 

 

 
 

INTRODUCTION 

 

This manual contains all of the information needed for 
the proper installation and operation for your 

Excel™ 

bath.  The bath has been designed to give you years of 
relaxing trouble-free service, provided the unit is 
maintained and operated in accordance with these 
instructions. 
 
Thoroughly clean and disinfect the unit as described in 
the 

CLEANING

 section of the 

USER MAINTENANCE 

INSTRUCTIONS

 

section of this owner’s manual before 

its first use and periodically thereafter. 
 

CAUTION:

 Keep hair, towels and clothing away from 

any installed suction fitting whenever the equipment is 
ON.  Never operate the equipment with the suction 
cover off, doing so voids the manufacturer’s warranty—
it is a safety cover designed to eliminate the potential of 
hair and body entrapment. 
 
All Jason 

Excel™ baths are pre-plumbed at the factory. 

 

WARNING: Before operating, refer to the 
instructions at the beginning of this owner’s manual 
pertaining to the risk of fire, electric shock or injury 
to persons. 
 
Filling and Draining 

Close the drain and fill the bath with water to the 
desired level (at least two (2) inches (50mm) above the 
jet). The inlet temperature should not exceed 104°F 
(40°C). When bath is in use, turn the unit OFF before 
draining the water. The bath unit and its plumbing are 
designed to drain after each use whether used as a 
hydrotherapy bath, soaking bath, or just taking a 
shower. 

 

NOTE: 

If the unit fails to operate, check the breaker 

panel to ensure that the circuit breaker is on. Check the 
GFCI by testing and resetting it. If the unit still fails to 
operate, refer to the Trouble Shooting Guide section of 
this manual. If the unit still fails to operate and is out of 
warranty, contact an authorized service technician for 
repair. If the unit is within the warranty period, contact 
JASON Technical Services at 800-255-5766

. DO NOT 

ATTEMPT TO RESOLVE THE PROBLEM.

 

 

 
 
 

 

 

WHIRLPOOL FEATURES 

Whirlpool Pump 

Whirlpool pumps provided on Jason baths are factory 
tested after installation on the bath.  The pumps are of 
efficient design incorporating high quality long life seals 
which provide superior service.  However, should the 
pump need service; suction and discharge unions are 
provided for easy pump removal. 
 

Whirlpool Jets 

Strategically placed whirlpool jets are provided for 
complete enjoyment of your bath. The jets are specially 
designed for maximum whirlpool action with directional 
capabilities.  By changing the direction of the jets, you 
can concentrate the massaging jet stream to your area 
of preference.  You can also individually adjust the flow 
of each jet. 
 

Air ON/OFF Button  

The Air On/Off button (air 
switch activator) provides 
a safe and convenient 
method for controlling the 
Whirlpool bath.  The Air 
On/Off button is factory 
mounted onto the bath 
prior to shipment.  To operate, fill the bath to at least 
two (2) inches above the jets and press the Air On/Off 
button to start or stop the whirlpool pump.   

 

 

 
 
 

 

FEATURES, CONTROLS AND OPERATING INSTRUCTIONS

 

Summary of Contents for Excel Series

Page 1: ...installation Damage to the unit during installation will not be covered by warranty and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INST...

Page 2: ...ol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Lower water temperatures are recommended for extended use exceeding 10 15 minutes and f...

Page 3: ...s de 10 15 minutes et pour les jeunes enfants F Puisque les temp ratures excessives ont un potentiel lev pour les f tus durant les premiers mois de la grossesse les femmes enceintes ou possiblement en...

Page 4: ...fore servicing For baths requiring two circuits CAUTION Not Suitable for Field Installed Heater ATTENTION la temperature ambiante sous la baignoire o l quipement est install ne doit pas d passer 50 C...

Page 5: ...her used as a hydrotherapy bath soaking bath or just taking a shower NOTE If the unit fails to operate check the breaker panel to ensure that the circuit breaker is on Check the GFCI by testing and re...

Page 6: ...llowing procedures should be followed Note Do no remote mount the blower more than 15 feet 4 5m away from the air inlet of the bath Choose a location as close as possible to the bath to ensure maximum...

Page 7: ...ghly after cleaning SURFACE MAINTENANCE Area with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jas...

Page 8: ...um of 72 F 22 C 3 Drain and Overflow Install the drain and overflow assembly to the bath shell according to the instructions provided with the drain and position the bath in the area of intended insta...

Page 9: ...ce of this bath has been provided with a protective film which helps protect the bath during shipment and installation If the bath is tiled in remove the necessary portion of the film when installing...

Page 10: ...and not interrupted by a switch Never use a switch in conjunction with a control device This will VOID THE MANUFACTURER S WARRANTY The pumps are supplied with an electrical bonding lug to allow connec...

Page 11: ...If no voltage control is defective b Motor is not plugged into control box b Make sure plug is fully inserted into the control box outlet c Air switch Plastic air tubing disconnected or broken c Check...

Page 12: ...nt of equipment shall be F O B point of shipment This warranty shall not apply to any merchandise which has been subject to accident alteration abuse misuse abrasives corrosion and or electrolysis imp...