IMPORTANT SAFETY INSTRUCTIONS

INSTRUCTIONS PERTAINING TO THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO 

PERSONS.

This manual contains information and instructions for proper operation and maintenance of your therapy bath.  Failure to 
follow these instructions could result in personal injury, electrical shock, or fire.

WARNING: WHEN USING THIS UNIT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, 

INCLUDING THE FOLLOWING:

READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

DANGER:

 

TO REDUCE THE RISK OF INJURY FOLLOW THESE PRECAUTIONS: 

A.

  Do not permit children to use this product unless they are closely supervised at all times.

B.

  Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the 

manufacturer.

C.

  The water in a  therapy bath should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F 

(40°C) are considered safe for a healthy adult. Use time should be limited to approximately 30 minutes, followed by 
a shower to cool down. Longer exposures may result in hyperthermia. The symptoms of this condition are nausea, 
dizziness and fainting, and it can be fatal. Lower water temperatures are recommended for extended use (exceeding 
10 -15 minutes) and for young children.

D.

  Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, 

pregnant or possibly pregnant women should limit therapy bath water temperatures to 100°F (38°C).

E.

  The use of drugs or alcoholic beverages before or during therapy bath use may lead to unconsciousness with the 

possibility of drowning. Never use the therapy bath while under the influence of alcohol, anticoagulants, stimulants, 
antihistamines, vasoconstrictors, vasodilators, hypnotics, narcotics, or tranquilizers.

F.

  Persons with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes 

should consult a physician before using a therapy bath.

G.

  Persons using medication should consult a physician before using a therapy bath since some medication may induce 

drowsiness while other medication may affect heart rate, blood pressure, and circulation.

DANGER:

 

 

To reduce the risk of injury, enter and exit the bath slowly. 

WARNING:

 NEVER OPERATE ELECTRICALLY CONNECTED DEVICES IN OR NEAR THE BATH. NEVER DROP OR INSERT ANY OBJECT INTO ANY 

OPENING.

This unit must be connected to a supply circuit that is protected by a GFCI. Such a device should be installed by a licensed 
electrician and should be tested on a regular basis (at least monthly). To test the GFCI push the 

TEST

 button. The GFCI 

should interrupt the power. Push the 

RESET

 button and the power should be restored. If the GFCI fails to operate in this 

manner, there is the possibility of an electric shock. 

DO NOT USE. 

Disconnect the unit and have the problem corrected by a 

qualified service technician. 
To avoid the possibility of personal injury and discoloration of the acrylic surface, the inlet water temperature should not 
exceed 104°F (40°C). The bath should be drained after each use. Each bather should start their bath with fresh water. Do 
not use oil base additives in your therapy bath.

CAUTION: Do not use harsh abrasives or solvents for cleaning this unit.

INSTALLER/OWNER BEARS ALL RESPONSIBILITY TO COMPLY WITH ALL STATE 

AND LOCAL CODES WHEN INSTALLING THIS PRODUCT.

SAVE THESE INSTRUCTIONS

JASON INTERNATIONAL, INC.

8328 MacArthur Drive  •  North Little Rock  •  Arkansas  •  72118

www.jasoninternational.com 

Summary of Contents for Carrera 5184.00.00.01

Page 1: ... event of a problem DO NOT install the unit The factory is not responsible for damage that might have been avoided by inspection or test ing prior to installation 49 1015 000 Date 01 2016 Damage to the unit during installation will not be covered by warranty and is the responsibility of the installer ALL WAR RANTY CLAIMS ON CARRERA COMPOSITE SURFACE DAMAGE MUST BE MADE PRIOR TO INSTALLATION Inspec...

Page 2: ...here the two bottom support ribs will sit The supports are approximately 13mm wide and run the length of the base Figure 1 A 5 Attach the bath drain to the floor drain P trap CAUTION Only dry fit the drain to the P trap at this time Leave the drain assembly free standing in the P trap 6 Place the bath using caution not to scratch the surface Align the bath with the centerlines of the template Assu...

Page 3: ...Jason International Inc 501 771 4477 Page 3 of 5 Customer Service 800 255 5766 Copyright 2016 Jason International Figure 2 Figure 2 A INSTALLATION INSTRUCTIONS cont ...

Page 4: ...moldysurfacesassoonasanymoldappearsbyusing a detergent soapy solution and appropriate household cleaner Always use gloves during cleaning Dispose of any sponges or rags used to clean mold CLEANING AND SURFACE MAINTENANCE The Carrera Composite solid surface is nonporous Stains mold mildew or bacteria cannot penetrate the surface When frequently cleaned the Carrera Composite solid sur face will main...

Page 5: ...the possibility of drowning Never use the therapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication s...

Reviews: