Jasic TIG200 User Manual Download Page 9

8

4) The welding operation shouldn’t be done in the dust or environment containing corrosive gas.

5) The welding operation shouldn’t be done in the environment of strong airflow.

2.

2.

Safety

Safety

keys

keys

The welding machines can automatically stop work when the setting standards, like the electric network voltage,

the output current and built-in temperature are exceeded because of the protection circuits of over-voltage,

over-current and over-heat. But the welding machine can be also damaged when it is over-uses( e.g. over voltage),

therefore the following matters should be noticed:

1) Assure good ventilation!

The welding machine is small welding machine. The natural ventilation can’t satisfy the machine’s cooling

demands once a larger current passes through it when it works. Therefore a fan is mounted inside the machine

for cooling the machine and making it run stably. The user should ensure the ventilated place isn’t covered

and stemmed. The distance between welding machine and the surrounding objects is at least 0.3m. The good

ventilation very important for the machine to work better and use longer.

2)

2) Over-load is prohibited!

The users should remember to observe the maximum permission load current (should be corresponding with

selected load endurance ratio) and keep it not exceeding the maximum permission load current.
Over-current would shorten the machine’s life and even burn-out the machine.

3) Over-voltage is prohibited!

The power voltage is listed in the table of “main performance parameters”. The welding current keeps in the

allowable range because of the machine’s voltage autocompensation circuit in common case. The users ought

to know the welding machine may be damaged if the power voltage exceeds allowable value and take

corresponding precautionary measures.

4) The back of every welding machine is attached a grounding screw marking a sign of grounding. A cable with

section of at least 6mm

2

is used for grounding to release static electricity and prevents the accidents caused

by electricity leakage.

5) The welding machine should suddenly enter protection state and stop working if the load endurance ratio is

exceeded. This indicates standard load endurance ratio is already exceeded and over heat triggers temperature

controlling switch. Therefore the machine stops working and the yellow indicator lamp lights at the same

time. The power plug needn’t be pulled out cause the cooling fan can continuously runs and cools the

welding machine. The welding process can be continued when the red indicator lamp extinguishes and the

temperature falls into the standard range.

Possible problems in welding:

The status listed below may be related with fitting parts, gas, environment and power supply. Please try to

improve the condition and avoid the following circumstances appears.

A.

Welded

Welded

dots

dots

become

become

black

black

:

:

It shows that the welded dots are not protected effectively and oxidized. You can check:

1. Make sure the valve of the argon gas bottle is open and have enough pressure which is generally not lower than
0.5MPa, or else, the bottle should be refilled.

2. Make sure that the flow of argon gas is enough. You can choose different flow in terms of various welding
current, but too little flow may lead to protected gas’s stiffness is inadequate and can’t cover all the welded dots.
We propose that the flow of argon gas can’t be smaller than 3l/min no matter how small the current is.

3. The simplest way to check whether there is gas being sent out is putting your hand near the nozzle to check

Summary of Contents for TIG200

Page 1: ...S MANUAL MODEL AC DC TIG 200 AC DC TIG 250 AC DC TIG 315 INVERTER SERIES Read first please Thank you In order to protect you and others please read this manual and understand it completely before ope...

Page 2: ...ctive clothing welding protective mask and glass filter Avoid doing harm to lookers on by using appropriate mask or curtain Fire hazard Make sure there is no tinder near operating position because the...

Page 3: ...he following advantages lower price high applicability for power system The most advantage of this machine is that it adopts double inverting technology and generates a clear square wave Its output ca...

Page 4: ...0 2 0 2 0 2 Duty ratio 20 80 20 80 20 80 Down slope time S 0 5 0 5 0 5 Post gas S 2 10 2 10 2 10 Remote control Non available Available Available Arc initiation High frequency High frequency High freq...

Page 5: ...invert in positive and negative direction circularly when take a argon arc welding operation It is positive current time when current flows from tungsten needle to workpiece and it is suitable for wel...

Page 6: ...n chamber according to the input voltage grade of welding machine The connected voltage must be correct The power voltage should varies in a permitted range at the same time The welding machine can be...

Page 7: ...ual requirement 1 The current is controlled by knob on the control panel when the transfer switch locates at OFF position 2 The current is controlled by foot switch when the transfer switch locates at...

Page 8: ...ne which should be dry if the state above occurs and insulation state should be checked with megohmmeter insulation status of connected nodes as well as connected nodes and casing The welding machine...

Page 9: ...g machine may be damaged if the power voltage exceeds allowable value and take corresponding precautionary measures 4 The back of every welding machine is attached a grounding screw marking a sign of...

Page 10: ...network connected with input cable and assure it is available 3 Check input cable and find out any short circuit Power indicator lights but fan does not rotate or stops after several rotations and no...

Page 11: ...cator does not light 2 If the abnormal indicator does not light a The transformer on middle board may be damaged pls check the primary inductance and Q value with bridge circuit b The double times rec...

Page 12: ...the machine and unplug the power terminal of high frequency arc starting power supply near the VH 07 inserter and restart the machine i Individual MOFSET on MOS board is damaged if the abnormal indica...