Jasic TIG200 User Manual Download Page 8

7

Warning!

Strictly

Strictly

prohibit

prohibit

inserting

inserting

and

and

pushing

pushing

the

the

cable

cable

or

or

plugs

plugs

in

in

the

the

course

course

of

of

welding

welding

because

because

the

the

operations

operations

may

may

hurt

hurt

the

the

operator

operator

and

and

damage

damage

machine.

machine.

Maintenance

Warning!

All

All

the

the

maintenance

maintenance

and

and

examination

examination

must

must

be

be

carried

carried

on

on

after

after

cutting

cutting

off

off

the

the

power

power

.

.

P

P

lease

lease

make

make

sure

sure

that

that

the

the

power

power

plug

plug

is

is

pulled

pulled

out

out

before

before

opening

opening

the

the

casing.

casing.

1. Dust should be blown away with dry and clean compressed air termly; The welding machine should be

cleaned every day if it is operated under the circumstance of polluted air.

2. Pressure of the compressed air should be appropriate so as to protect the small components inside the welding

machine.

3. Examine circuits in the welding machine regularly and make sure they are connected correctly and firmly

(especially the plugs and components). If they are rusty or loose, abrasive paper can be used to remove the

rust or oxide film, and they should be reconnected and fixed.

4. Water or vapor are prevented from entering the welding machine, which should be dry if the state above

occurs, and insulation state should be checked with megohmmeter (insulation status of connected nodes, as

well as connected nodes and casing). The welding machine can work continually only when everything is

normal.

5. If the welding machine will not be used for a long time, it should be put back into the original packing case

and stored in dry circumstance.

Before inspection

Warning!

Blind

Blind

fold

fold

experience

experience

and

and

incautious

incautious

inspection

inspection

may

may

cause

cause

trouble

trouble

s

s

for

for

the

the

formal

formal

inspection.

inspection.

When

When

the

the

machine

machine

is

is

on

on

position,

position,

and

and

the

the

voltage

voltage

of

of

bare

bare

parts

parts

in

in

the

the

machine

machine

is

is

dangerous

dangerous

.

.

A

A

ny

ny

direct

direct

or

or

indirect

indirect

contact

contact

may

may

bring

bring

about

about

shock

shock

hazard,

hazard,

even

even

death!!!

death!!!

Note:

During warranty period, maintenance free guarantee provided by supplier will out of service if the user

inspects and repairs the welding cut power without our permit.

Notice and Preventive Measures

1.

Environment

Environment

1) The welding operation requires a relative dry environment and air humidity should not be beyond 90%.

2) The surrounding temperature should be kept in a range from -10

to 40

.

3) The water or rainwater is prohibited from permeating into the welding machine, and the welding operation

shouldn’t be done in the sun or rain.

i

i

Summary of Contents for TIG200

Page 1: ...S MANUAL MODEL AC DC TIG 200 AC DC TIG 250 AC DC TIG 315 INVERTER SERIES Read first please Thank you In order to protect you and others please read this manual and understand it completely before ope...

Page 2: ...ctive clothing welding protective mask and glass filter Avoid doing harm to lookers on by using appropriate mask or curtain Fire hazard Make sure there is no tinder near operating position because the...

Page 3: ...he following advantages lower price high applicability for power system The most advantage of this machine is that it adopts double inverting technology and generates a clear square wave Its output ca...

Page 4: ...0 2 0 2 0 2 Duty ratio 20 80 20 80 20 80 Down slope time S 0 5 0 5 0 5 Post gas S 2 10 2 10 2 10 Remote control Non available Available Available Arc initiation High frequency High frequency High freq...

Page 5: ...invert in positive and negative direction circularly when take a argon arc welding operation It is positive current time when current flows from tungsten needle to workpiece and it is suitable for wel...

Page 6: ...n chamber according to the input voltage grade of welding machine The connected voltage must be correct The power voltage should varies in a permitted range at the same time The welding machine can be...

Page 7: ...ual requirement 1 The current is controlled by knob on the control panel when the transfer switch locates at OFF position 2 The current is controlled by foot switch when the transfer switch locates at...

Page 8: ...ne which should be dry if the state above occurs and insulation state should be checked with megohmmeter insulation status of connected nodes as well as connected nodes and casing The welding machine...

Page 9: ...g machine may be damaged if the power voltage exceeds allowable value and take corresponding precautionary measures 4 The back of every welding machine is attached a grounding screw marking a sign of...

Page 10: ...network connected with input cable and assure it is available 3 Check input cable and find out any short circuit Power indicator lights but fan does not rotate or stops after several rotations and no...

Page 11: ...cator does not light 2 If the abnormal indicator does not light a The transformer on middle board may be damaged pls check the primary inductance and Q value with bridge circuit b The double times rec...

Page 12: ...the machine and unplug the power terminal of high frequency arc starting power supply near the VH 07 inserter and restart the machine i Individual MOFSET on MOS board is damaged if the abnormal indica...

Reviews: