Page 33
5.0
2
)
If the "Welding Mode" is MIG, set the MIG post-flow
time, with range of 0-5.0, accuracy of 0.5, and unit of
seconds.
2) If the "Welding Mode" is Lift TIG, set the Lift TIG
post-flow time, with range of 0-10.0, accuracy of 0.5,
and unit of seconds.
Lift TIG
downslope
time
F05
0.5
Set the Lift TIG downslope time, with range of 0-5,
accuracy of 0.5, and unit of second.
Burn back
voltage
F06
13.0
Set the MIG burn back voltage, with range of
10.0-20.0, accuracy of 0.1, and unit of voltage.
MMA hot start
current
F07
30
Set the MMA hot start current, with range of 0-60,
accuracy of 1, and unit of ampere.
Slow wire
feed speed
F08
3
Set the slow wire feed speed of MIG; can be set to "0",
"1", "2" or "3".
1) "0" indicates that the slow wire feed function is
disabled.
2) "1" and "2" indicate that the slow wire feed speed is
1/3 or 1/2 of the current set speed, respectively.
3) "3" indicates that the current slow wire feed speed is
3m/min.
Remote
control mode
F09
0
Can be set to "0" or "1" to use wired or wireless remote
controller.
1) "0" indicates wireless remote controller.
2) "1" indicates wired remote controller.
NOTE!
If entering the Welding Engineer Mode from different "Welding Mode" states,
the functional definition corresponding to the background parameters/functions may
be also different!