Jasic LC-30 Quick Start Manual Download Page 9

Page 9

Fault Phenomenon and Solution:

Symptom

Corrective Action

The power light does not light

up, the water pump does not

work, water does not flow in the

water pipe and the fan does not

work.

1 Inspect whether the power line is connected correctly.

2 Inspect and confirm that input cables are connected to

power supply.

3 Inspect whether the patch cord of the main board is

loose. If so, please tighten it

The power light lights up, the

water pump does not work,

water does not flow in the water

pipe and the fan does not work.

The flow warning light lights up.

1 Inspect whether the fan gets stuck by foreign matters. If

any, remove foreign matters.

2 Inspect whether the patch cord of the main board is

loose. If so, please tighten it

3 Inspect whether the main board outputs DC24V. If not,

replace the main board.

The power light lights up, the

water pump does not work,

water does not flow in the water

pipe and the fan works properly.

The flow warning light lights up.

1 Inspect whether the patch cord of the main board is

loose. If so, please tighten it

2 Inspect whether the main board outputs DC24V. If not,

replace the main board.

3 The water pump works properly at DC24V. If the water

pump does not work, it is damaged and should be

replaced.

The power light lights up, the

water pump works properly,

water flows in the water pipe

and the fan does not work.

1 Inspect whether the fan gets stuck by foreign matters. If

any, remove foreign matters.

2 Inspect whether the patch cord of the main board is

loose. If so, please tighten it

3 Inspect whether the main board outputs DC24V. If not,

replace the main board.

4 The fans works properly at DC24V. If the fan does not

work, it is damaged and should be replaced.

The power light lights up, the

water pump works properly,

water flows in the water pipe

and the fan works properly. The

flow warning light lights up.

1 Inspect whether internal lines are loose. If any, please

tighten them.

2 Inspect whether the flow switch works properly. If water

flows in the water pipe, the flow switch is opened.

Otherwise, the flow switch is closed. In case of

abnormalities, please replace the flow switch.

3 If coolant contains impurities, the flow switch will break

down or be damaged. Please replace the flow switch.

Summary of Contents for LC-30

Page 1: ...Copyright 2022 Shenzhen JASIC Technology Co Ltd LC 30 C0S1 WATER COOLER...

Page 2: ...nt domestic and international standards and that this product conforms to EN60974 1 International Safety Standard Patents protect the relevant design scheme and manufacturing technology adopted in thi...

Page 3: ...Overview 5 3 Performance Features 5 4 Technical Parameters 5 5 Installation and Operating Instructions 6 6 Precautions 8 7 Fault and Maintenance 8 Appendix A Packaging Transportation and Storage 11 A...

Page 4: ...incombustible object otherwise a fire may be caused Do not place combustible materials near this product otherwise a fire may be caused Explosion Do not install this product where there are explosive...

Page 5: ...onmental and pollution free 4 Technical Parameters Note Some parameters are acquired under experimental conditions Technical Parameters Units LC 30 COS1 Rated input voltage V Single phase AC115 230V 1...

Page 6: ...ower than 5 Please fill the kettle with water when it is used for the first time Cover the water tank and power on it The power light lights up the water pump starts to work and water will flow out of...

Page 7: ...add coolant cooling water when the input cable is disconnected to the power grid 2 The filter screen in the water filling nozzle of the kettle cannot be removed If unfiltered coolant is added impurit...

Page 8: ...alt 7 Fault and Maintenance Safety Warning The following operations can only be carried out by operators with sufficient electrical expertise and comprehensive safety knowledge and with valid qualific...

Page 9: ...is loose If so please tighten it 2 Inspect whether the main board outputs DC24V If not replace the main board 3 The water pump works properly at DC24V If the water pump does not work it is damaged an...

Page 10: ...tighten them 3 Inspect whether the temperature switch is normal If the water temperature is higher than the maximum temperature of the temperature switch the temperature switch is closed If the water...

Page 11: ...ess of handling equipment it shall be handled with care and it shall not be severely impacted Moisture and rain shall be prevented during transportation A 3 Storage Storage temperature 20 60 Storage h...

Page 12: ...Page 12 Appendix B Wiring Diagram of Complete Machine AC115V AC230V 1 50Hz M 5 2 1 3 4 FAN Flow Switch Thermal Protection Light PCBA...

Page 13: ...Page 13...