![Jasic LC-30 Quick Start Manual Download Page 7](http://html2.mh-extra.com/html/jasic/lc-30/lc-30_quick-start-manual_4822976007.webp)
Page 7
Front panel description:
1 Return pipe (red)
2 Outlet pipe (blue)
3 Overheat warning light
4 Flow warning light
5 Power light
6 Water filling nozzle of kettle
7 Drainage port
Description of rear panel:
1 Power line
Water level description:
The lowest water level should be no lower than the indication line in
work; otherwise, abnormalities may be caused.
Notes:
1 Please ensure to add coolant (cooling water) when the input
cable is disconnected to the power grid.
2 The filter screen in the water filling nozzle of the kettle
cannot be removed. If unfiltered coolant is added, impurities
may block the waterway system and consequently the
machine may be damaged.
Drainage:
Open the front bottom drain port for drainage.
Note: Please ensure to drain water when the input cable is
disconnected to the power grid.
Interface definition:
1
、
2
:
AC115-230V/1~ 50Hz
;
3, 4: Abnormal signal;
5: Ground wire;
Note: The power line is furnished with aviation plug.
5
4
3
1
2
7
6
1
1
2
3
4
5