TIG REMOTE CONTROL SET-UP PROCEDURE
The 5 pin remote control socket located on the front panel is used to connect a TIG torch trigger switch
and/or torch mounted current adjustment dial as well as a foot pedal or similar remote device.
Remote device activation
1.
Turn the machine ON.
2.
Set machine to either TIG standard or TIG pulse mode in the welding mode selection area.
3.
Set peak current to 200amps.*
4.
Place upslope and downslope time to 0 (zero).
5.
Set machine to 2T trigger mode.
Press and hold the trigger switch for 7 seconds until the front panel Arc Force indicator illuminates.
Remote current control is now active. (* Setting the current to 200A allows full range current adjustment
via the remote device connected).
Please note:
The maximum output current must be set on the power source control panel by the user prior to
the foot control being connected.
Remote control deactivation is done by pressing the trigger switch for 7 seconds until the Arc Force
indicator turns off which indicates that you are now out of remote current control mode.
Pin
Description
1
Potentiometer max
2
Potentiometer min
3
Torch switch
4
Potentiometer wiper
5
Torch switch
Remote plug wiring
TIG Torch Plug
Peak Current Welding mode selection
Upslope 2T Arc Force Downslope