15
REMOTE CONTROL CONNECTION
Jasic JP-61/81 Plasma CNC Connections
2 Pin socket
Pin 1: - Divided Arc Signal output *
Pin 2: + Divided Arc Signal output *
4 Pin Socket
Pin 1: Remote Start/Stop **
Pin 2: Remote Start/Stop **
Pin 3: OK to move signal ***
Pin 4: OK to move signal ***
*
Pins 1 & 2 – Output, which provides the divided arc signal output for a torch height
controller (THC), the factory divided voltage options are 50:1, 30:1 and 20:1
**
Pin 1 and 2 – Input, which requires a normally open dry contact closure to activate
the plasma
*** Pins 3 & 4 – Output, provides the OK to move signal output which is a normally
open, dry contact closure when the plasma arc transfers
PRIOR TO A CNC INSTALLATION, ALWAYS CHECK THE DIVIDED ARC SETTING TO ENSURE
ITS CORRECTLY SET FOR YOUR INSTALLATION!
The following operation requires sufficient professional knowledge on electric aspects and
comprehensive safety knowledge. Make sure the input cable of the machine is disconnected
from the electricity supply and wait for 5 minutes before removing the machine covers.
To set the Jasic Plasma’s divided arc voltage to be compatible with the CNC tables torch
height controller you will need to have a technician remove the covers of the JT-61/JT-81
machine , locate the soldered links on the main PCB and re-solder the link to your THC CNC
cutting table requirements.