A WILKINSON STAR LIMITED PRODUCT                                                                                                                                    01-19 ISSUE 1 

ensure natural airflow. 

Input connection 

Before connecting the machine you should ensure 
that  the  correct  supply  is  available.  Details  of  the 
machine  requirements  can  be  found  on  the  data 
plate  of  the  machine  or  in  the  technical 
parameters shown in the manual. 

The equipment should be connected by a suitably 
qualified  competent  person.  Always  ensure  the 
equipment has a proper grounding. Never connect 
the  machine  to  the  mains  supply  with  the  panels 
removed. 

Output connections 

Insert  the  torch  connector  into  the  connection 
socket  and  turn  clockwise  until  it  is  tight  taking 
care  not  to  over  tighten.  No  air  should  leak  from 
this connection. 

Insert the work return cable into the socket and 
tighten by turning clockwise. 

 

 

Check leads and connections daily before use. 

Connect the work clamp to the work piece. 

Air pressure adjustment 

The embedded filter regulator is correctly set when 
leaving the factory and users do not need to set it 
themselves in general. 

If users need to reset the embedded filter reducer 
the  following  steps  are  to  be  taken.  Only  suitably 
qualified persons should make any adjustments. 

Switch off the machine at the mains supply. 

Remove the machine cover. 

Switch on the mains supply and the machine  
taking care not to touch any electrical parts. 

Press the gas check button on the front panel 
and air will flow. 

Lift the pressure control knob upwards. 

Adjust  the  gas  pressure to  the desired  value 
by  rotating  the  knob  (rotate  to 

+

 

direction  to  increase  gas  pressure;  rotate  to 

-

 direction to reduce gas pressure). 

Press down the pressure control knob to lock 
it.  

Any  water  in  the  filter  bowl  will  drain  when 
the  air  is  off  through  the  bottom  tube  and 
out of the machine.  

 

PLEASE 

NOTE 

TO 

PROVIDE 

OPTIMUM 

PERFORMANCE  AIR  SHOULD  BE  CLEAN  AND  DRY. 
THE  ADJUSTMENT  REGULATOR  IN  THE  MACHINE 
IS NOT DESIGNED AS A DRYER/FILTER. 

Operation method 

Turn on the power switch of the machine and the 
power indicator illuminates. 

Select  correct  working  mode  and    function.  There 
are  two  working  modes  available  on  the  machine 
panel:  2T  and  4T.  There  are  two  functions 
available:  normal  cutting  and  metal  mesh  cutting. 
The electrode and nozzle wear more quickly when 
using the mesh cutting mode. 

Set  cutting  current  according  to  the  thickness  of 
work piece to be cut. 

Bring the copper nozzle of the cutting torch to the 
work  piece  keeping  a  distance  of  about  2mm 
between  the  copper  nozzle  of  the  torch  and  the 
work  piece.  Push  the  torch  trigger  on  the  cutting 
torch, the machine will start a pilot arc and cutting 

Summary of Contents for JP-45PWV

Page 1: ...A WILKINSON STAR LIMITED PRODUCT 01 19 ISSUE 1 ...

Page 2: ...distributor in the unlikely event of a problem occurring Please record below the details from your product as these will be required for warranty purposes and to ensure you get the correct information should you require assistance or spare parts Date Purchased ________________________________________ From Where ________________________________________ Serial Number ________________________________...

Page 3: ...ing in cramped or restricted positions Ensure that the equipment is well maintained Repair or replace damaged or defective parts immediately Carry out any regular maintenance in accordance with the manufacturer s instructions Safety against fumes and welding gases Locate the equipment in a well ventilated position Keep your head out of the fumes Do not breathe the fumes Ensure the welding zone is ...

Page 4: ...spheres with high concentrations of combustible fumes flammable gases and dust Always check the work area half an hour after cutting to make sure that no fires have begun Risks due to magnetic fields The magnetic fields created by high currents may affect the operation of pacemakers or electronically controlled medical equipment Wearers of vital electronic equipment should consult their physician ...

Page 5: ...s the DC voltage which is rectified from 50Hz 60Hz input AC voltage to 30K 100KHz AC high voltage Then the voltage is dropped and rectified to output the high power DC power supply for cutting The machine adopts switching power supply inverter technology greatly reducing the volume and weight of the plasma cutter and obviously enhancing the power efficiency The switching frequency is beyond audio ...

Page 6: ...at the mains supply 2 Remove the machine cover 3 Switch on the mains supply and the machine taking care not to touch any electrical parts 4 Press the gas check button on the front panel and air will flow 5 Lift the pressure control knob upwards 6 Adjust the gas pressure to the desired value by rotating the knob rotate to direction to increase gas pressure rotate to direction to reduce gas pressure...

Page 7: ... min It is recommended not to ignite the arc in the air if not necessary for it will shorten the lifespan of the electrode and nozzle of the torch It is recommended to initiate the cutting from the edge of the work piece unless penetration is needed Ensure spatter flies from the bottom of work piece while cutting If spatter flies from the top of the work piece it indicates that the work piece is n...

Page 8: ...ITED PRODUCT 01 19 ISSUE 1 PANEL LAYOUT FRONT 1 Pressure gauge 2 Work return socket 3 Torch connector socket 4 2T 4T selector 5 Air purge cut selector 6 Current adjustment knob REAR 7 Mains switch 8 Mains cable 9 Air inlet ...

Page 9: ...L THE FAN COOLS IT DOWN AND THE INDICATOR GOES OFF 3 TORCH PROTECTION INDICATOR THIS WILL BE LIT IF TORCH CONSUMABLES ARE WORN OR DAMAGED THE MACHINE WILL BE OFF UNTIL THE FAULT IS CLEARED 4 AIR PRESSURE GUAGE 5 2T 4T SELECTOR THE LED WILL BE LIT TO INDICATE THE SWITCH MODE 6 GAS CHECK MESH CUTTING INDICATOR WHEN THE TOP POSITION IS LIT AIR WILL FLOW BUT THE MACHINE WILL NOT CUT WHEN THE MESH CUTT...

Page 10: ... Ensure the power is disconnected before working on the machine Always wait 5 minutes after power switch off before opening the case Period Maintenance item Daily examination Check the condition of the machine mains cables welding cables and connections Replace where necessary Switch on the machine and check for any warning LEDs and general operation Monthly examination Disconnect from the mains s...

Page 11: ...nic which has reached its end of life must be collected separately and disposed of via a suitable recycling facility The owner of the equipment is required to return the equipment to a suitable recycling facility or to Wilkinson Star Limited for the correct recycling of the product Malfunction Cause Solution Turn on the machine the power indicator illuminates the control PCB keys work normally but...

Page 12: ...A WILKINSON STAR LIMITED PRODUCT 01 19 ISSUE 1 Cut Series JP 45PWV Order code JP 45PWV Wilkinson Star Limited ...