THE OPTITEX™ COVER

OptiTex is a durable hygiene cover with unique features contributing to the mattress’s 
pressure relieving properties.

The multi-stretch, breathable cover is made of a polyurethane (PU) material. The entire 
cover (bo

th upper and lower parts) can be cleaned with disinfectants or machine washed at 

maximum 95° C and tumble dried.

The OptiTex cover has an integrated waterproof cable holder that reduces the risk of bacteria 
spreading, keeps the electrical cord out of the way and protects the air hoses. 

Cells and hoses can easily be removed from the cover and rinsed clean with disinfectants or 
with warm water at maximum 70° C.

The Low Air Loss function

 allows air to escape from the cells whilst at the same time 

remaining waterproof. This microclimate management together with the bi-elastic surface 
layer reduces the risk of shear and other complications for the patient.

Fluid protection flap

 and waterproof zip on four sides, with welded seams.

Underside 

with four fastening straps.

APPLICATIONS

The OptiCell Soft PLUS is a constant low air pressure overlay mattress, which is placed on top 
of a foam mattress (for example, one of Järven Health Care’s standard mattresses). It aids the 
prevention and treatment of pressure ulcers up to and including Category 3.

OptiCell Soft PLUS has a height of 13cm and comes with a durable OptiTex cover and a CPR 
valve for emergency situations.

The supplied OC-15 pump provides constant low air pressure only. It is easy to use and 
can be adjusted manually to adapt to the patient’s weight.

FIRE PROTECTION

The OptiCell Soft PLUS mattress is tested and approved according to 

SS 8760001

EN 597-1

 

and 

EN 597-2

.

SYSTEM FEATURES

The OptiCell Soft PLUS air mattress is constructed so that individual cells can be 
disconnected, even while a patient is lying on the mattress. The mattress has three different 
types of cells:

• 

Head cells

 – 13cm high, continuously inflated air cells that are positioned under the 

patient’s head.

• 

Standard cells

 – 13cm high, static air pressure section.

• 

Ventilation cells

 – function as standard cells, but with ventilation holes releasing small 

amounts of air up into the cover. This creates air circulation that helps keep the top of 
the cover dry.

Individual cells can easily be disconnected:

•  Release the air hose from the chosen cell (press the black button on the air hose coupling).

•  Press the two buttons on the short sides of the cell.

AIR HOSE PUMP CONNECTION

The OptiCell Soft PLUS air mattress is connected to the pump by three air hoses.

The red air hose, positioned in the middle, is used to fill the head cells situated under the 
patient’s head. It also fills the lower chambers of the standard cells and the ventilation cells.  
This ensures that there is always air in the mattress no matter how the pump is set, or if the 
pump should stop working (for example, due to power failure).

The outer two air hoses provide static pressure to the standard cells and ventilation cells.  
See the section “Air hose connection” (page 10) for more information.

THE PUMP’S DIFFERENT WORKING METHODS

By changing the pump’s setting according to the patient’s weight, you have a static air 
pressure mattress with different degrees of constant low air pressure. Examples of different 
working methods: 

•  By removing individual cells, relief can be given to specific body parts (for example  

the heels).

•  By inserting a ventilation cell, a fresher feeling can be created when the patient senses 

that the cover feels warm in a specific area.

Summary of Contents for OptiCell Soft PLUS

Page 1: ...1 USER GUIDE OptiCell Soft PLUS Constant low air pressure overlay mattress...

Page 2: ...important to the user Risk of damage to mattress Important information denoted by this symbol must be observed in order not to damage the mattress or other material CE MARKING J rven Health Care hygi...

Page 3: ...Categories 1 3 low risk to very high risk for patients within the weight range 30 230 kg The product is intended for use with a sheet between the patient s skin and the mattress surface The mattress...

Page 4: ...01 EN 597 1 and EN 597 2 SYSTEM FEATURES The OptiCell Soft PLUS air mattress is constructed so that individual cells can be disconnected even while a patient is lying on the mattress The mattress has...

Page 5: ...re We recommend that the mattress be kept rolled up in one of our optional transport bags The mattress should not be treated carelessly when stored as it risks being damaged Avoid exposing the mattres...

Page 6: ...ny problems with the mattress s air pressure The test ensures that the patient does not bottom out How the hand check is performed The hand check should always be performed when the patient is positio...

Page 7: ...on but the pump does not work contact J rven Healthcare The mattress does not inflate properly pressure too low Set the pressure to maximum check if the air hoses are pinched anywhere or if there is a...

Page 8: ...mately 15 minutes When the lamp is lit the mattress is ready to use UNLOCK The panel can be locked to prevent unauthorised people from changing the system settings To unlock the panel press and hold t...

Page 9: ...slation EU Directive 85 374 EEC Swedish Law SFS 1992 18 establishes the manufacturer s importer s or seller s statutory liability for any damage caused by the product The regulations apply to physical...

Page 10: ...ent regarding pressure relief and must be conducted by staff with adequate knowledge and education Based on the patient s assessed status the appropriate mattress is chosen for the correct purpose and...

Page 11: ...0 824 10 Email healthcare jarven se OptiCell Soft PLUS user guide All trademarks are the property of their respective owners J rven AB reserves the right to update this guide if necessary and or on fi...

Reviews: