Program
End
Interleaved 2 of 5 code length
Bar Code Symbologies
While Interleaved 2 of 5 is easily
decoded, it is also subject to errors if
parameters such as length are not well
adjusted. The default code length is
fixed at 10 digits. The variable setting
allows the code length to vary from 3
to 32 digits (even number only) :
• Scan “Program”
• Scan “Variable”
• Scan “End”
And if chosen, the use of the check
digit is recommended.
The option of changing from the pre-
set length of 10 is also available. To
do this, you must first enable reading
of the “Full ASCII” character set
under the Code 39 configuration. The
programming procedure is then as
follows:
•
Scan “
P
rogram”
•
Scan
“
Fixed”
•
Scan the desired length from the ASCII
Table
•
Scan
“
Set”
•
Scan
“
End”
The ASCII Code Table is found in
Appendix II.
Set
Fixed
Variable
Summary of Contents for 2008
Page 1: ...Bar Code CCD Scan ner Operation Manual...
Page 4: ...2...
Page 12: ...10...
Page 27: ...25 Parity Program End Even Odd Space None Data Bit 7 8 Stop Bit 2 1 RS232 Parameters...
Page 38: ...36 Codabar Length MAX LEN MIN LEN Set Program End Bar Code Symbologies...
Page 44: ...42...
Page 46: ...44 Troubleshooting...
Page 50: ...48...
Page 52: ...50 ASCII Code Table DC2 ESC DC3 FS GS DC4 EM CAN ETB US SYN RS NAK SUB SP...
Page 53: ...51 ASCII Code Table 2 1 0 5 4 3...
Page 54: ...52 6 G F E D C B 9 A 8 7 ASCII Code Table...
Page 55: ...53 P Y X O W N V M U L T K S J R I Q H ASCII Code Table...
Page 56: ...54 ASCII Code Table b k a j i h _ g f e d c Z...
Page 57: ...55 ASCII Code Table t s r z q y p x o w n v m u l...
Page 58: ...56 DEL ASCII Code Table...
Page 59: ...ISSUED NOV 97 V 7...