REX F-0-9– Standalone or Access Controller
3/2015
Black line
www.jantar.si
REX F-0-9 – STANDALONE OR ACCESS CONTROLLER
The Rex is a controller with built-in fingerprint reader. It is
designed for residential and business buildings, offices, shops, etc.
In various operation modes, the controller allows access for up to
500 users (2 master finger 500 user fingerprints).
As a standalone controller, the entire set-up procedure is carried
out with the master fingerprint. User fingerprints can either be
registered or deleted.
As an access controller, the entire set-up procedure is carried out
with the software.
The controller signals normal operation with flashing red and green
LED. It can also be used as a Wiegand 26-bit reader, if needed.
TECHNICAL DATA
REX F-0-9
Current consumption
50mA
Operating voltage
From 9V to 14V DC
Operating temperature
From -20°C to 60°C
Communication
RS485
Dimensions (mm)
58x120x17 (WxHxD)
Sensor protection
> 15kV ESD protection
Usage
> 1 million wear cycles
Cabel
Cable through or on the wall
– 3m
Mounting height
140cm from the ground
Memory
500 fingerprints
500 events
Inputs
Door status
Push button
Outputs
Transistor output for el.
strike 0.5A
Inputs
Door status
Push button
Clock
Real time clock, battery
backup (max. ten hours)
CONNECTION CABLE
Wire-Color
Description/Wiegand 26-
bit
Specification
1 – Red
9-14V DC
Power supply
2 – Gray/Black GND
Ground
3 – Green
El. strike output / Data 0
Max. 0.5A
Active = GND
4 – White
Alarm output/ Data 1
Active = GND
5 – Yellow
Door status switch input/
Buzzer input
Active = GND
6 – Orange
Push button input /
LED input
Active = GND
7 – Blue
CA
RS485 A line
8 – Brown
CB
RS485 B line
LED DIODES
Color
Description
Flashing red/green
Normal mode
Lit green
El. strike is unlocked
Lit red
Fingerprint has no rights
Power supply
The controller need’s external power supply to operate. The
Spider W40 power supply is sufficient to power two controllers and
two 12V electric strikes or two 12V magnetic locks (0.5A). If you
will use it as a standalone controller and low consumption electric
strike (0.25A) you can use power supply Spider W5.
Voltage drops and cable signal interferences
When you connect the controller, use cable with a diameter of at
least 0.22mm
2
. If the cable length exceeds 25m, use one twisted
pair of UTP cables for the positive (+) pole and one for the
negative (-) pole. The cable length between power supply and the
controller should not exceed 50m.
Take into consideration that a 0.22mm
2
cable has a resistance of
approximately 9 ohm per 100m. The power supply at the end of
cable should be a minimum of 9V. If you are using el. strike, it is
highly recommended that the voltage drop is calculated. At greater
distances, a thicker cable of 0.5mm
2
or more should be used
wherever possible.
If the load is, for example, 0.5A (with el. strike) then, on the
0.22mm
2
cable voltage drop will be 4.5V at 100m. For the device
with 60mA consumption, the voltage drop is 0.5V.
Inputs, outputs and environment
Inputs:
Inputs are realized with opto-isolators. The input is active, when
pulled to ground with an open collector transistor or mechanical
switch, which is connecting the input pin of the controller to the
Ground.
Outputs:
Output has a pre-installed protection diode for an inductive load. It
is also protected from current overload. The best way is to use a
0.25A el. strike or a 0.5A el. magnet, which has to be connected to
the same positive pole (+) as the controller. Connect the negative
pole (-) to the door strike output (wire 3). When the output is
active it is pulled to ground. This can be changed with function 5 –
negate output (for el. magnet).
Environment:
It is designed for indoor, non-condensing, applications. Do not
expose the controller to direct contact with the elements such as
rain, snow or sunlight.
If the plastic housing is in a different color
than black, then there is a chance that the color will change (to
some extend) in a few months or years if exposed to direct
sunlight.
The sensor surface is hard and extremely robust, and will
withstand years of normal wear-and-tear. Do not subject the
sensor to sharp or hard objects since this might cause permanent
damage. Cleaning should be done with a lint-free cotton textile. Do
not subject the sensor surface to mechanical force.
You must assure good cable joints, protected against moisture,
otherwise corrosion may damage the controller. Damage in such
cases is not covered by the warranty.
Installation of Rex F
Remove black plastic screw covers on the top and the bottom of
the controller. Install the controller
to the wall with two supplied
screws. Use diagonal holes - it enables a small correction of the
position of the controller (up, down, left, right). When the
controller is installed, put the screw covers back on.