REX F-0-9– Standalone or Access Controller 

 

 

 

 

3/2015 

Black line 

www.jantar.si 

 

 

 

 

 

 

 

                                         

 
 

 

 

 

        

 

 

REX F-0-9 – STANDALONE OR ACCESS CONTROLLER  

 

The Rex is a controller with built-in fingerprint reader. It is 

designed for residential and business buildings, offices, shops, etc. 

In various operation modes, the controller allows access for up to 

500 users (2 master finger 500 user fingerprints).  

As a standalone controller, the entire set-up procedure is carried 

out with the master fingerprint. User fingerprints can either be 

registered or deleted.  

As an access controller, the entire set-up procedure is carried out 

with the software.  
The controller signals normal operation with flashing red and green 

LED. It can also be used as a Wiegand 26-bit reader, if needed. 

 

TECHNICAL DATA 

REX F-0-9 

Current consumption 

50mA 

Operating voltage 

From 9V to 14V DC 

Operating temperature 

From -20°C to 60°C 

Communication 

RS485 

Dimensions (mm)  

58x120x17 (WxHxD) 

Sensor protection 

> 15kV ESD protection  

Usage 

> 1 million wear cycles 

Cabel 

Cable through or on the wall 

– 3m 

Mounting height 

140cm from the ground 

Memory  

500 fingerprints  

500 events 

Inputs 

Door status  

Push button 

Outputs 

Transistor output for el. 

strike 0.5A  

Inputs 

Door status  

Push button 

Clock 

Real time clock, battery 

backup (max. ten hours) 

 

CONNECTION CABLE 

Wire-Color 

Description/Wiegand 26-

bit 

Specification 

1 – Red 

9-14V DC 

Power supply 

2 – Gray/Black  GND 

Ground 

3 – Green  

El. strike output / Data 0 

Max. 0.5A 
Active = GND 

4 – White 

Alarm output/ Data 1 

Active = GND 

5 – Yellow 

Door status switch input/  

Buzzer input 

Active = GND 

6 – Orange 

Push button input /     

LED input 

Active = GND 

7 – Blue 

CA 

RS485 A line 

8 – Brown  

CB 

RS485 B line 

 

LED DIODES 

Color 

Description 

Flashing red/green 

Normal mode  

Lit green 

El. strike is unlocked 

Lit red  

Fingerprint has no rights  

 

 

 

Power supply 

The controller need’s external power supply to operate. The 

Spider W40 power supply is sufficient to power two controllers and 

two 12V electric strikes or two 12V magnetic locks (0.5A). If you 
will use it as a standalone controller and low consumption electric 

strike (0.25A) you can use power supply Spider W5.  

 

 

Voltage drops and cable signal interferences 

When you connect the controller, use cable with a diameter of at 

least 0.22mm

2

. If the cable length exceeds 25m, use one twisted 

pair of UTP cables for the positive (+) pole and one for the 

negative (-) pole. The cable length between power supply and the 

controller should not exceed 50m. 

Take into consideration that a 0.22mm

2

 cable has a resistance of 

approximately 9 ohm per 100m. The power supply at the end of 

cable should be a minimum of 9V. If you are using el. strike, it is 

highly recommended that the voltage drop is calculated. At greater 

distances, a thicker cable of 0.5mm

2

 or more should be used 

wherever possible. 

If the load is, for example, 0.5A (with el. strike) then, on the 

0.22mm

2

 cable voltage drop will be 4.5V at 100m. For the device 

with 60mA consumption, the voltage drop is 0.5V. 

 

Inputs, outputs and environment 

Inputs: 

Inputs are realized with opto-isolators. The input is active, when 

pulled to ground with an open collector transistor or mechanical 

switch, which is connecting the input pin of the controller to the 

Ground. 

 

Outputs: 

Output has a pre-installed protection diode for an inductive load. It 

is also protected from current overload. The best way is to use a 

0.25A el. strike or a 0.5A el. magnet, which has to be connected to 

the same positive pole (+) as the controller. Connect the negative 

pole (-) to the door strike output (wire 3). When the output is 

active it is pulled to ground. This can be changed with function 5 – 

negate output (for el. magnet). 

 

Environment:

 

It is designed for indoor, non-condensing, applications. Do not 

expose the controller to direct contact with the elements such as 

rain, snow or sunlight. 

If the plastic housing is in a different color 

than black, then there is a chance that the color will change (to 

some extend) in a few months or years if exposed to direct 

sunlight.

 

The sensor surface is hard and extremely robust, and will 

withstand years of normal wear-and-tear. Do not subject the 

sensor to sharp or hard objects since this might cause permanent 

damage. Cleaning should be done with a lint-free cotton textile. Do 
not subject the sensor surface to mechanical force.  

You must assure good cable joints, protected against moisture, 

otherwise corrosion may damage the controller. Damage in such 

cases is not covered by the warranty.  

 

Installation of Rex F

        

 

Remove black plastic screw covers on the top and the bottom of 
the controller. Install the controller

 

to the wall with two supplied 

screws. Use diagonal holes - it enables a small correction of the 

position of the controller (up, down, left, right). When the 

controller is installed, put the screw covers back on.

 

 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for REX F-0-9

Page 1: ... of UTP cables for the positive pole and one for the negative pole The cable length between power supply and the controller should not exceed 50m Take into consideration that a 0 22mm2 cable has a resistance of approximately 9 ohm per 100m The power supply at the end of cable should be a minimum of 9V If you are using el strike it is highly recommended that the voltage drop is calculated At greate...

Page 2: ...e process with the same fingerprint this fingerprint will be deleted Next registered fingerprint will take the first available position on the list or position of the deleted fingerprint If you would like to delete the fingerprint of the user that no longer exists you must maintain a list of registered fingerprints arranged in order of registrations positions functions 6 and 7 Function 2 Pulse tim...

Page 3: ...place a user fingerprint on the sensor confirmation Delete all with the Codeks Device Manager program Set the Rex to the default settings by using the Codeks Device Manager program Connect the Rex via RS485 communication line to the Spider communication converter USB or NET Connect the Spider to the computer In Codeks Device Manager find the device and perform the Brain Wash function which sets th...

Page 4: ...d Jantar software Up to 128 controllers can be lined up into one communication line The maximum length of the communication line is 1000 cable meters It is recommended that you use an FTP or S FTP cable Only a serial connection of controllers in a single communication line is allowed Star parallel connection is not allowed All shields of S FTP cables must be wired together and at one point connect...

Page 5: ...of 9V If you are using el strike it is highly recommended that the voltage drop is calculated At greater distances a thicker cable of 0 5mm2 or more should be used wherever possible If the load is for example 0 5A with el strike then on the 0 22mm2 cable voltage drop will be 4 5V at 100m For the device with 60mA consumption the voltage drop is 0 5V Reading distance depends on where the controller ...

Page 6: ...led the controller signals with a longer beep If the registration is successful the user fingerprint is registered and with it the user can open output on the controller If you repeat the process with the same fingerprint this fingerprint will be deleted Next registered fingerprint or card will take the first available position on the list or position of the deleted fingerprint If you would like t...

Page 7: ... sensor or approach a card which was registered after the one you wish to delete This will delete the previous fingerprint or card on the list Next registered fingerprint or card will take the position of a deleted fingerprint or deleted card Delete a fingerprint or a lost card with master card Approach the master card and remove it after 7 double beeps Within a period of three seconds approach th...

Page 8: ... 255 to any number between 1 and 254 If you have more controllers on the communication line don t duplicate addresses Add them one by one on the communication line because every controller has address 255 by default Communication Connect the controller to the computer with one of the power supplies with built in communication converter from the Spider family Spider W5 USB Spider W5 NET Spider W40 ...

Reviews: