30
Upper feed dog (1)
To check:
1. Attach the dual feed foot and needle #14.
2. Remove the face plate. (Refer to page 1)
3. Turn the power switch ON while pressing the start/
stop button and the reverse stitch button to enter the
factory setting mode.
4. Press the “Dualfeed” key to select the dual feed
adjusting mode.
Set the offset value at “0”, the balancing value at “5”,
the stitch length value at “0”.
5. Lower the feed dog and press the needle up/down key
twice to raise the needle. Turn the power switch off.
* To initialize the feed dog position, be sure to press
the needle up/down key twice to raise the needle.
6. Lower the presser foot lifter.
7. Raise the toe of the dual feed foot and leave it as it is.
8. Turn the handwheel toward you to lower the needle
until the needle tip comes 1 mm or less above the
needle plate. The toe of the foot lands on the needle
plate and there is no gap to allow the foot flapping.
If not, adjust it as follows.
The needle tip should be 0 to 1 mm above the surface of the needle plate when the toe of
the dual feed foot touch the needle plate.
Surface of
the needle
plate
0 to 1 mm
away from the
needle plate
No clearance
Clearance
Reverse button
Start/stop button