25
5. Thread Drawing Lever
[1] Remove the base.
[2] Loosen the setscrew (1) and free the stopper (2).
[3] Turn the handwheel toward you to raise the needle
bar from the lowest position until the needle point is
10.9 mm (1600P-DB/DBX) or 10.5 mm (1600P)
above the upper surface of the needle plate.
[4] Push the solenoid disk (3) fully to swing the thread
drawing lever (4).
Loosen the setscrew (5) and move the thread draw-
ing arm (6) to the left or right so that the tip of the
thread drawing lever (4) lightly contacts with the
bobbin.
[5] Tighten the setscrew (5).
[6] Restore the stopper (2) and press it against the
thread drawing lever (4), while pushing the solenoid
disk (3).
Tighten the setscrew (1) firmly.
[7] Attach the base.
(1)
(2)
(3)
(5)
(4)