Janfire NH Burner Service Installation Manual 4.16.09 - Technical specifications are subject to change without prior
notice.
9(38
)
Fitting Instructions for Outdoor temperature sensor
Location: If the rooms which temperature is to be regulated all face the same direction (same cardinal point) the
temperature sensor has to be placed on that side.
In any other case, see to it that the temperature sensor is placed on the coldest side of the building (north,
northeast).
The temperature sensor is not to be fitted over windows or doors because of outstreaming warm air, neither
should it be placed in a recess (niche) in the wall.
Figure 3. Micro switch
Figure 4. Ash scrape moving base
The moving base of the burning chamber scrapes away slag and waste material, feeding it into the boiler firebox based
on pre-programmed pellets consumption.
A micro switch prevents the burner from
operating when detached from the boiler
bulk head.
The moving base in
operational position
The moving base
in cleaning position