Page 8
ENGLISH
Jandy
®
Pro Series TruClear
™
Chlorine Generating System
|
Installation & Operation Manual
Section 2. General Description
Figure 1.
Example of Installation
2.1 Product Specifi cations
Maximum Operating Pressure: 50 psi
Input Freq: 60 Hz
Minimum Flow Rate: 76 lpm (20 gpm)
Output Voltage: 25V DC (max)
Required Salt Level: 3.0 gpl (3,000 ppm)
Dimensions:
Power Pack (L x W x H):
25.4 cm x 11.4 cm x 33 cm (10 in. x 4.5 in. x 13 in.)
Electrolytic Cell (L x W x H):
16.5 cm x 14 cm x 30.5 cm (6.5 in. x 5.5 in. x 12 in.)
Maximum water volume treated:
132,000 L (35,000 gal.)
Chlorine Output:
0.42 kg (0.93 lbs) per day
Input Voltages: 240 VAC
Weight:
Power Pack: 3.2 kg. (7 lbs)
Electrolytic Cell: 0.9 kg (2 lbs)
Input Current @ 240 VAC: ~1 A
HEATER
CELL
FILTER
POWER PACK
TO COMMON
POWER SOURCE
CHECK VALVE
RETURN
WATER FEATURE /
IN FLOOR CLEANER
INTAKE
PUMP
ENGLISH
The cell must be installed
as the last piece of equipment in
the circulation plumbing system
just before the pool.