background image

5. 

The pump foundation must have adequate drainage 

to prevent the motor from getting wet. The pump 

needs to be protected from the rain and sun.

6. 

Proper ventilation is required for the pump 

to operate normally. All motors generate heat 

that must be removed by providing proper 

ventilation.

7. 

Provide access for future service by leaving a 

clear area around the pump. Allow plenty of 

space above the pump to remove the lid and 

basket for cleaning.

8. 

If the equipment is under cover, provide 

adequate lighting.

3.1.3  Pipe Sizing

NOTE

  All HP ratings given in this section apply to full-rated 

pumps. For help with max-rated pumps, contact 

Zodiac Technical Support at 800.822.7933.

3.1.3.1 

Suction Pipe

When the pump is located up to 50 feet from the pool, 

the recommended minimum pipe size for the suction 

side of the pump is:

•  2" for .75 to 1.5 HP*

•  2½" for 2.0 HP* 

•  3" for 3.0 HP* 

•  4" for 5.0 HP*

* HP refers to full-rated pumps

3.1.3.2 

Discharge Pipe

When the pump is located up to 50 feet from the pool, 

the recommended minimum pipe size for the discharge 

side of the pump is:

NOTE

  Better self-priming will be achieved if the pump is 

installed as close as possible to the water level of the 

pool.

2. 

If the pump is located below water level, 

isolation valves must be installed on both the 

suction and return lines to prevent back flow 

of pool water during any routine or required 

servicing. 

Some Safety Vacuum Release System (SVRS) de

-

vices are not compatible with installation of check 

valves. If the pool has an SVRS device, be sure to 

confirm that it will continue to safely operate when 

any check valves are installed.

 

WARNING

3. 

Install the pump such that any disconnecting 

means and/or junction boxes for power 

connection are withing sight of the pump and at 

least five (5) feet horizontally from the edge of 

the pool and/or spa. Choose a location that will 

minimize turns in the piping. 

NOTE

  In Canada, the minimum distance maintained from 

the edge of the pool and/or spa as noted above must 

be 3 meters (10 feet), as required by the Canadian 

Electrical Code (CEC, CSA C22.1).

4. 

The pump should be installed on a firm, solid, and 

level surface to avoid risk of settlement. Do not 

use sand to level the pump as sand will wash away. 

Check local building codes for any additional 

requirements (Ex. Equipment pads in Florida must 

be concrete and equipment must be secured to the 

pad.)

NOTE

  Zodiac Pool Systems LLC recommends bolting the 

pump directly to the foundation.

AQUAPURE

MANUAL BY-PASS DETAIL
MANUAL BY-PASS IS USED
WHEN FILTRATION RATE
EXCEEDS 125 GPM

Figure 2.  Typical Piping Installation

Page 7 

ENGLISH

Jandy

®

 Pro Series Stealth

 Pumps   

|

   Operation Manual

Summary of Contents for Stealth SHPM

Page 1: ...of the instructions in this manual can be followed exactly Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning not...

Page 2: ...2 Section 5 Service and Maintenance 12 5 1 Routine Maintenance 12 5 2 Winterizing the Pump 13 Section 6 Troubleshooting 14 6 1 Troubleshooting 14 Section 7 Product Specifications and Technical Data 15...

Page 3: ...without the test button being pushed a ground current is flowing indicating the possibility of electri cal shock Do not use the pump Disconnect the pump and have the problem corrected by a qualified...

Page 4: ...o ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing Water pressure for test must NOT EXCEED 35 PSI Water temperature for test must NOT EXCEED 1...

Page 5: ...eed the suction fitting assembly and it s cover s maximum design flow rate The suction outlet drain assembly and its cover must comply with the latest version of ANSI ASME A112 19 8 the standard for S...

Page 6: ...r strength and corrosion resistance The pump is driven by an electric motor directly attached to the pump impeller As the electric motor turns it causes the impeller to turn which forces water to flow...

Page 7: ...level isolation valves must be installed on both the suction and return lines to prevent back flow of pool water during any routine or required servicing Some Safety Vacuum Release System SVRS de vic...

Page 8: ...installation requirements NOTE To prevent entrapment the system must be built so that it cannot operate with the pump drawing water from only one 1 main drain At least two 2 main drains must be connec...

Page 9: ...must be adequate to minimize voltage drop during the start up and operation of the pump See Table 2 for recommended wire sizes RECOMMENDED MINIMUM WIRE SIZE FOR SHP PUMPS Distance from Sub Panel 0 50...

Page 10: ...ck hazard resulting in severe personal injury or death WARNING Due to the potential risk of fire electric shock or injuries to persons Jandy Pro Series Pumps must be installed in accordance with the N...

Page 11: ...KS WARNING When pressure testing the system with water it is very important to make sure that the pump basket lid on the filter pump is completely secure WARNING Do not pressure test above 35 PSI Pres...

Page 12: ...or a suction leak and then repeat Steps 2 through 7 Section 5 Service and Maintenance 5 1 Routine Maintenance Inspect the pump basket for debris by looking through the clear pump lid Remove any debris...

Page 13: ...the o rings Drain Plug with O ring Set R0446000 3 Keep the motor covered and dry NOTE Covering the pump with plastic will create condensation and this moisture will damage the pump The best way to pro...

Page 14: ...the lid o ring and place on the lid Hand tighten the lid to make an air tight seal Do not use any tools to tighten the lid Turn the pump back on Air leaks are still present Check the suction side pipi...

Page 15: ...g Mech Seals SHPF 5 0 R0445201 3 Impeller Replacement Kit SHPF 50 R0807204 3 Impeller Replacement Kit SHPF 75 R0807203 3 Impeller Replacement Kit SHPF 1 0 1 0 2 R0807202 3 Impeller Replacement Kit SHP...

Page 16: ...and Ceramic All R0479400 6 Body Pump SHPF SHPM All R0445601 7 Motor Mounting Foot Assembly w Screws SHPF SHPM All R0445700 8 Lid w Locking Ring Seal All R0445800 9 Blue Pressure Test O ring All R0479...

Page 17: ...pecifications Model No HP Voltage Amps Pipe Size Carton Weight Overall Length A SHPF 50 50 208 230 115 4 4 4 5 8 8 2 2 30 lbs 311 8 SHPF 75 75 208 230 115 6 0 5 6 11 2 2 2 43 lbs 317 8 SHPF 1 0 1 0 20...

Page 18: ...SHPM 2 5 2 5 208 230 11 0 10 0 2 2 57 lbs 331 8 SHPM 1 5 2SPD 1 5 230 7 2 3 0 2 2 52 lbs 321 8 SHPM 2 0 2SPD 2 0 230 10 0 3 5 2 2 57 lbs 325 8 SHPM 2 5 2SPD 2 5 230 11 0 4 0 2 2 64 lbs 331 8 113 8 16...

Page 19: ...NOTES Page 19 ENGLISH Jandy Pro Series Stealth Pumps Operation Manual...

Page 20: ...ol Systems LLC 2620 Commerce Way Vista CA 92081 1 800 822 7933 www ZodiacPoolSystems com 2017 Zodiac Pool Systems LLC ZODIAC is a registered trademark of Zodiac International S A S U used under licens...

Reviews: