Section 7.  Product Specifications and Technical Data

7.1  Replacement Parts List

To order or purchase parts for Zodiac

®

 pumps, contact your nearest Zodiac dealer. If they cannot supply you with what 

you need, contact Zodiac technical support at 800.822.7933 or send an e-mail message to: 

[email protected]

.

Key No.

Description

Model No. (HP)

Order Part No.

1

Single-speed Motor & Hardware, SHPF 

.50

R0445114

1

Single-speed Motor & Hardware, SHPF

.75

R0445101

1

Single-speed Motor & Hardware, SHPF  

1.0

R0445102

1

Single-speed Motor & Hardware, SHPF  

1.5

R0445103

1

Single-speed Motor & Hardware, SHPF 

2.0

R0445104

1

Single-speed Motor & Hardware, SHPF 

3.0

R0445105

1

Single-speed Motor & Hardware, SHPF

5.0

R0490200

1

Single-speed Motor & Hardware, SHPM

.75

R0479301

1

Single-speed Motor & Hardware, SHPM 

1.0

R0479302

1

Single-speed Motor & Hardware, SHPM 

1.5

R0479303

1

Single-speed Motor & Hardware, SHPM 

2.0

R0479304

1

Single-speed Motor & Hardware, SHPM

2.5

R0479305

1

Two-speed Motor & Hardware, SHPM

1.5 

R0479307

1

Two-speed Motor & Hardware, SHPM 

2.0

R0479308

1

Two-speed Motor & Hardware, SHPM  

2.5

R0479309

1

Single-speed Motor & Hardware, SHPF, 3 Phase

1.0

R0479101

1

Single-speed Motor & Hardware, SHPF, 3 Phase 

1.5

R0479102

1

Single-speed Motor & Hardware, SHPF, 3 Phase

2.0

R0479103

1

Single-speed Motor & Hardware, SHPF, 3 Phase 

3.0

R0479104

1

Two-speed Motor & Hardware, SHPF

1.0

R0445113

1

Two-speed Motor & Hardware, SHPF 

1.5

R0445106

1

Two-speed Motor & Hardware, SHPF 

2.0

R0445107

2

Backplate Kit w/Hardware, O-ring & Mech Seals, SHPF/SHPM

.50-3.0

R0445200

2

Backplate Kit w/Hardware, O-ring & Mech Seals, SHPF

5.0

R0445201

3

Impeller Replacement Kit, SHPF

.50

R0807204

3

Impeller Replacement Kit, SHPF

.75

R0807203

3

Impeller Replacement Kit, SHPF

1.0, 1.0-2

R0807202

3

Impeller Replacement Kit, SHPF

1.5, 1.5-2

R0807201

3

Impeller Replacement Kit, SHPF

2.0, 2.0-2

R0807200

3

Impeller Replacement Kit, SHPF

3.0

R0807205

3

Impeller Replacement Kit, SHPF

5.0

R0807207

Symptom

Possible Problem/Solution

There is no debris blocking 

the impeller 

and

 the pressure 

is still low.

The pump impeller and diffuser are showing signs of normal wear. Have a qualified 

service technician check the impeller and diffuser and replace as necessary.
If the pump is part of a relatively new installation, it could be an electrical problem. 

Contact a qualified service technician. Have the technician check for loose electrical 

connections and check the voltage at the pump motor while it is in operation. The 

voltage must be within 10% of the motor's data plate rating. If the voltage is not 

within 10%, contact a qualified electrician and/or the local power service provider.

The pump is leaking water 

between the motor and pump 

body.

This is caused by a damaged or failed mechanical seal. Pump seal is leaking air. 

Have a qualified service technician replace the seal. 

The pump gets hot and shuts 

off periodically.

Ensure that there is adequate room around the motor to circulate air and keep the 

motor cool. Have a qualified electrician check for loose connections and check the 

voltage at the pump motor while it is in operation. The voltage must be within 10% 

of the motor's data plate rating. If the voltage is not within 10%, contact a qualified 

electrician and/or the local power service provider.

Page 15 

ENGLISH

Jandy

®

 Pro Series Stealth

 Pumps   

|

   Operation Manual

Summary of Contents for Stealth SHPM

Page 1: ...of the instructions in this manual can be followed exactly Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning not...

Page 2: ...2 Section 5 Service and Maintenance 12 5 1 Routine Maintenance 12 5 2 Winterizing the Pump 13 Section 6 Troubleshooting 14 6 1 Troubleshooting 14 Section 7 Product Specifications and Technical Data 15...

Page 3: ...without the test button being pushed a ground current is flowing indicating the possibility of electri cal shock Do not use the pump Disconnect the pump and have the problem corrected by a qualified...

Page 4: ...o ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing Water pressure for test must NOT EXCEED 35 PSI Water temperature for test must NOT EXCEED 1...

Page 5: ...eed the suction fitting assembly and it s cover s maximum design flow rate The suction outlet drain assembly and its cover must comply with the latest version of ANSI ASME A112 19 8 the standard for S...

Page 6: ...r strength and corrosion resistance The pump is driven by an electric motor directly attached to the pump impeller As the electric motor turns it causes the impeller to turn which forces water to flow...

Page 7: ...level isolation valves must be installed on both the suction and return lines to prevent back flow of pool water during any routine or required servicing Some Safety Vacuum Release System SVRS de vic...

Page 8: ...installation requirements NOTE To prevent entrapment the system must be built so that it cannot operate with the pump drawing water from only one 1 main drain At least two 2 main drains must be connec...

Page 9: ...must be adequate to minimize voltage drop during the start up and operation of the pump See Table 2 for recommended wire sizes RECOMMENDED MINIMUM WIRE SIZE FOR SHP PUMPS Distance from Sub Panel 0 50...

Page 10: ...ck hazard resulting in severe personal injury or death WARNING Due to the potential risk of fire electric shock or injuries to persons Jandy Pro Series Pumps must be installed in accordance with the N...

Page 11: ...KS WARNING When pressure testing the system with water it is very important to make sure that the pump basket lid on the filter pump is completely secure WARNING Do not pressure test above 35 PSI Pres...

Page 12: ...or a suction leak and then repeat Steps 2 through 7 Section 5 Service and Maintenance 5 1 Routine Maintenance Inspect the pump basket for debris by looking through the clear pump lid Remove any debris...

Page 13: ...the o rings Drain Plug with O ring Set R0446000 3 Keep the motor covered and dry NOTE Covering the pump with plastic will create condensation and this moisture will damage the pump The best way to pro...

Page 14: ...the lid o ring and place on the lid Hand tighten the lid to make an air tight seal Do not use any tools to tighten the lid Turn the pump back on Air leaks are still present Check the suction side pipi...

Page 15: ...g Mech Seals SHPF 5 0 R0445201 3 Impeller Replacement Kit SHPF 50 R0807204 3 Impeller Replacement Kit SHPF 75 R0807203 3 Impeller Replacement Kit SHPF 1 0 1 0 2 R0807202 3 Impeller Replacement Kit SHP...

Page 16: ...and Ceramic All R0479400 6 Body Pump SHPF SHPM All R0445601 7 Motor Mounting Foot Assembly w Screws SHPF SHPM All R0445700 8 Lid w Locking Ring Seal All R0445800 9 Blue Pressure Test O ring All R0479...

Page 17: ...pecifications Model No HP Voltage Amps Pipe Size Carton Weight Overall Length A SHPF 50 50 208 230 115 4 4 4 5 8 8 2 2 30 lbs 311 8 SHPF 75 75 208 230 115 6 0 5 6 11 2 2 2 43 lbs 317 8 SHPF 1 0 1 0 20...

Page 18: ...SHPM 2 5 2 5 208 230 11 0 10 0 2 2 57 lbs 331 8 SHPM 1 5 2SPD 1 5 230 7 2 3 0 2 2 52 lbs 321 8 SHPM 2 0 2SPD 2 0 230 10 0 3 5 2 2 57 lbs 325 8 SHPM 2 5 2SPD 2 5 230 11 0 4 0 2 2 64 lbs 331 8 113 8 16...