Jandy SHPF Installation And Operation Manual Download Page 5

Page 5

  CAUTION

This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so 
marked. Do not use with storable pools. A permanently installed pool is constructed in or above the ground 
or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so 
that it may be readily disassembled for storage and reassembled to its orig i nal integrity.

  CAUTION

Do not install within an outdoor enclosure or beneath the skirt of a hot tub or portable spa. The pump 
requires adequate ventilation to maintain air temperarture at less than the maximum ambient temperature 
rating listed on the motor rating plate. 

SAVE THESE INSTRUCTIONS

  WARNING

Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause filters and other equipment 
to fail, resulting in severe injury or property damage. Do not store pool chemicals near your equipment. 

 CAUTION

Do not start pump dry! 

Running the pump dry for any length of time will cause severe damage and will 

void the warranty.

  WARNING

To minimize risk of severe injury or death the filter and/or pump should not be subjected to the piping 
system pressurization test.

Local codes may require the pool piping system to be subjected to a pressure test. These requirements 
are generally not intended to apply to the pool equipment such as filters or pumps.

Jandy

® 

pool equipment is pressure tested at the factory.

If however the WARNING cannot be followed and pressure testing of the piping system must include the 
filter and/or pump BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:

•  Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed 

and secured before testing.

•  RELEASE ALL AIR

 in the system before testing.

•  Water pressure for test must NOT EXCEED 35 PSI.

•  Water temperature for test must NOT EXCEED 100°F (38°C).

•  Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.

•  Notice

: These parameters apply to Jandy

®

 equipment only. For non-Jandy

®

 equipment, consult  

equipment manufacturer.

Summary of Contents for SHPF

Page 1: ...llowed exactly Improper installation and or operation can create dangerous electrical hazards which can cause high voltages to run through the electrical system possibly causing death serious injury o...

Page 2: ......

Page 3: ...5 Service and Maintenance 12 5 1 Routine Maintenance 12 5 2 Winterizing the Pump 12 Section 6 Troubleshooting and Repair 13 6 1 Troubleshooting 13 6 2 Service Technician Maintenance 14 6 2 1 Blocked I...

Page 4: ...h multiport slide or full flow valve position with the pump running WARNING The Jandy Pumps are powered by a high voltage electric motor and must be installed by a licensed or certified electrician or...

Page 5: ...pump dry Running the pump dry for any length of time will cause severe damage and will void the warranty WARNING To minimize risk of severe injury or death the filter and or pump should not be subject...

Page 6: ...pump can be connected to a single suction line as long as the requirements above are met Water Velocity The maximum water velocity through the suction fitting or cover for any suction outlet must be 1...

Page 7: ...ed certified to ANSI ASME A112 19 8 Anti entrapment Cover Grate or Suction Fitting screw fastened to Main Drain Sump Listed certified to ANSI ASME A112 19 8 Anti entrapment Cover Grate or Suction Fitt...

Page 8: ...recommended to install the pump within one 1 foot above the water level The pump should not be elevated more than a few feet above the water level of the pool A check valve is recommended on the sucti...

Page 9: ...GPM 697 LPM 230 GPM 871 LPM 3 Stealth Pumps come equipped with unions on both the suction and discharge ports This feature simplifies installation service and eliminates the possibility of leaks at th...

Page 10: ...3 2 3 Electrical Wiring 1 Thepumpmotormustbesecurelyandadequately grounded using the green screw provided Ground before attempting to connect to an electrical power supply Do not ground to a gas suppl...

Page 11: ...ying all connections and clamps are secure according to the manufacturer s recommendations WARNING To avoid risk of damage or injury verify that all power is turned off before starting this procedure...

Page 12: ...at all valves have been returned to the proper position for normal operation 8 Open the pressure release valve on the filter and make sure it is clean and ready for operation 9 Turn on the power to th...

Page 13: ...he pump With clean union o rings hand tightening of the unions should create a seal If the unions still do not seal gently tighten with a large pair of tongue and groove pliers Do not over tighten The...

Page 14: ...in order to access the inlet and outlet of the impeller 6 2 2 Impeller Removal WARNING While servicing the pump switch off the circuit breakers at the power source Severe personal injury or death may...

Page 15: ...impeller center screw using a 3 Phillips screwdriver see Figure 5 NOTE The impeller center screw is a left hand threaded screw therefore turn the screw clockwise to loosen 8 Hold the motor shaft with...

Page 16: ...TE Prior to replacing the lid check for debris around the lid o ring seat as this will cause air leaks into the system 9 Hand tighten the lid to make an air tight seal Do not use any tools to tighten...

Page 17: ...quires that you replace the motor with the identical HP rating and service factor Jandy only 1 Have a qualified service technician or electrician properly disconnect the electrical wiring at the pump...

Page 18: ...PM 2 0 1 1 R0445107 Motor 2 speed SHPM 2 5 1 1 R0445101 07 Bolts Washers All 4 4 2 R0445200 Backplate SHPF SHPM Mechanical Seal Carbon Mechanical Seal Ceramic O ring Bolts Washers All 1 1 1 1 8 8 3 R0...

Page 19: ...ate All 1 14 R0446400 O ring Tail Piece All 2 15 R0446500 Diffuser Impeller Hardware Screw w O ring Self sealing Impeller Mounting Screw Diffuser Mounting Washer Diffuser Mounting O ring Diffuser All...

Page 20: ...0 150 200 250 0 10 20 30 40 50 Feet of Head P S I Jandy Stealth Series High Head Pumps Full Rated SHPF and Max Rated SHPM Flow Rate GPM 2 HP SHPF 2 5 SHPM 3 HP SHPF 1 5 HP SHPF 2 0 HP SHPM 1 HP SHPF 1...

Page 21: ...HPM Pump Specifications Model No HP Voltage Amps Pipe Size Carton Weight Overall Length A SHPM1 0 1 0 208 230 115 6 0 5 6 11 2 2 2 43 lbs 317 8 SHPM1 5 1 5 208 230 115 7 8 7 4 14 8 2 2 45 lbs 32 SHPM2...

Page 22: ...Smith Century Pump Model A O Smith Century SHPF 75 B661 N A N A SHPF 1 0 B841 SHPM 1 0 B863SE SHPF 1 5 B842 SHPM 1 5 B864SE SHPF 2 0 B843 SHPM 2 0 B865SE SHPF 3 0 B844 SHPM 2 5 B866SE SHPM 2 0 2SPD B...

Page 23: ...Page 23 NOTES...

Page 24: ...and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals su...

Reviews: