Jandy SHPF Installation And Operation Manual Download Page 12

Page 12

Section 5. Service and Maintenance

5.1 Routine 

Maintenance

The pump will collect any large debris present in 
the water at the pump basket. As debris accumulates 
it will begin to block the flow of water through the 
pump, and must be removed. The cleaner the basket 
is kept, the more effective and efficient the pump will 
perform. The pump lid is clear for easy inspection 
between cleaning.

1. 

To clean the basket, turn off the power to the 
pump. If the pump is located below the water 
level, close the isolation valves on the suction and 
discharge sides of the pump to prevent backflow 
of water. Turn the lid counter-clockwise until it 
comes off. You may use a tool for leverage to 
remove the lid, but 

never

 to tighten the lid.

 CAUTION

A misaligned basket will cause the lid to be 
improperly seated, allowing an air leak which could 
result in pump damage.

2. 

Lift the basket out of the pump.

3. 

Dispose of the debris and thoroughly clean the 
basket, making sure all the holes are open. Using 
a garden hose, spray the basket from the outside 
to help clear the holes. Use your hands to remove 
any remaining debris.

4.  Replace the basket in the pump by aligning 

the opening with the suction pipe. If aligned 
properly, the basket will drop easily into place. 

Do not force into place.

5. 

Prior to replacing the lid, check for debris around 
the lid o-ring seat, as this will cause air leaks into 
the system. Clean the lid o-ring and place on the 
lid.

6. 

Hand-tighten the lid to make an air tight seal. Do 
not use any tools to tighten the lid, hand-tighten 
only.

7. 

Verify that all valves have been returned to the 
proper position for normal operation.

8. 

Open the pressure release valve on the filter, and 
make sure it is clean and ready for operation. 

9.  Turn on the power to the pump. Once all the 

air has been evacuated from the filter, close the 
pressure release valve.

5.2 

Winterizing the Pump

 CAUTION

The pump 

must

 be protected when freezing 

temperatures are expected. Allowing the pump 
to freeze will cause severe damage and void the 
warranty.

 CAUTION

Do not use antifreeze solutions in the pool, 
spa, or hot tub systems! 

Antifreeze is highly 

toxic and may damage the circulation system. 
The only exception to this is Propylene Glycol. For 
more information see your local pool/spa supply 
store or contact a qualified swimming pool service 
company.

1. Drain 

all

 water from the pump, system 

equipment, and piping.

2.  Remove the two drain plugs. Store the drain 

plugs in a safe location and reinstall them when 
the cold weather season is over. 

Do not lose the 

o-rings.

4. 

Keep the motor covered and dry. 

NOTE

  Covering the pump with plastic will create 

condensation and this moisture will damage the 
pump. The best way to protect your pump is to 
have a qualified service technician or electrician 
properly disconnect the electrical wiring at 
the switch or junction box. Once the power is 
removed, the two unions can be loosened and the 
pump stored indoors. For safety, and to prevent 
entry of contaminants, reinstall all conduit and 
terminal box covers.

5. 

When the system is reopened for operation, make 
sure all piping, valves, wiring, and equipment 
are in accordance with the manufacturer's 
recommendations. Pay close attention to the 
filter and electrical connections.

6. 

The pump must be primed prior to starting; refer 
to 

Section 4.1, Start-up

.

Summary of Contents for SHPF

Page 1: ...llowed exactly Improper installation and or operation can create dangerous electrical hazards which can cause high voltages to run through the electrical system possibly causing death serious injury o...

Page 2: ......

Page 3: ...5 Service and Maintenance 12 5 1 Routine Maintenance 12 5 2 Winterizing the Pump 12 Section 6 Troubleshooting and Repair 13 6 1 Troubleshooting 13 6 2 Service Technician Maintenance 14 6 2 1 Blocked I...

Page 4: ...h multiport slide or full flow valve position with the pump running WARNING The Jandy Pumps are powered by a high voltage electric motor and must be installed by a licensed or certified electrician or...

Page 5: ...pump dry Running the pump dry for any length of time will cause severe damage and will void the warranty WARNING To minimize risk of severe injury or death the filter and or pump should not be subject...

Page 6: ...pump can be connected to a single suction line as long as the requirements above are met Water Velocity The maximum water velocity through the suction fitting or cover for any suction outlet must be 1...

Page 7: ...ed certified to ANSI ASME A112 19 8 Anti entrapment Cover Grate or Suction Fitting screw fastened to Main Drain Sump Listed certified to ANSI ASME A112 19 8 Anti entrapment Cover Grate or Suction Fitt...

Page 8: ...recommended to install the pump within one 1 foot above the water level The pump should not be elevated more than a few feet above the water level of the pool A check valve is recommended on the sucti...

Page 9: ...GPM 697 LPM 230 GPM 871 LPM 3 Stealth Pumps come equipped with unions on both the suction and discharge ports This feature simplifies installation service and eliminates the possibility of leaks at th...

Page 10: ...3 2 3 Electrical Wiring 1 Thepumpmotormustbesecurelyandadequately grounded using the green screw provided Ground before attempting to connect to an electrical power supply Do not ground to a gas suppl...

Page 11: ...ying all connections and clamps are secure according to the manufacturer s recommendations WARNING To avoid risk of damage or injury verify that all power is turned off before starting this procedure...

Page 12: ...at all valves have been returned to the proper position for normal operation 8 Open the pressure release valve on the filter and make sure it is clean and ready for operation 9 Turn on the power to th...

Page 13: ...he pump With clean union o rings hand tightening of the unions should create a seal If the unions still do not seal gently tighten with a large pair of tongue and groove pliers Do not over tighten The...

Page 14: ...in order to access the inlet and outlet of the impeller 6 2 2 Impeller Removal WARNING While servicing the pump switch off the circuit breakers at the power source Severe personal injury or death may...

Page 15: ...impeller center screw using a 3 Phillips screwdriver see Figure 5 NOTE The impeller center screw is a left hand threaded screw therefore turn the screw clockwise to loosen 8 Hold the motor shaft with...

Page 16: ...TE Prior to replacing the lid check for debris around the lid o ring seat as this will cause air leaks into the system 9 Hand tighten the lid to make an air tight seal Do not use any tools to tighten...

Page 17: ...quires that you replace the motor with the identical HP rating and service factor Jandy only 1 Have a qualified service technician or electrician properly disconnect the electrical wiring at the pump...

Page 18: ...PM 2 0 1 1 R0445107 Motor 2 speed SHPM 2 5 1 1 R0445101 07 Bolts Washers All 4 4 2 R0445200 Backplate SHPF SHPM Mechanical Seal Carbon Mechanical Seal Ceramic O ring Bolts Washers All 1 1 1 1 8 8 3 R0...

Page 19: ...ate All 1 14 R0446400 O ring Tail Piece All 2 15 R0446500 Diffuser Impeller Hardware Screw w O ring Self sealing Impeller Mounting Screw Diffuser Mounting Washer Diffuser Mounting O ring Diffuser All...

Page 20: ...0 150 200 250 0 10 20 30 40 50 Feet of Head P S I Jandy Stealth Series High Head Pumps Full Rated SHPF and Max Rated SHPM Flow Rate GPM 2 HP SHPF 2 5 SHPM 3 HP SHPF 1 5 HP SHPF 2 0 HP SHPM 1 HP SHPF 1...

Page 21: ...HPM Pump Specifications Model No HP Voltage Amps Pipe Size Carton Weight Overall Length A SHPM1 0 1 0 208 230 115 6 0 5 6 11 2 2 2 43 lbs 317 8 SHPM1 5 1 5 208 230 115 7 8 7 4 14 8 2 2 45 lbs 32 SHPM2...

Page 22: ...Smith Century Pump Model A O Smith Century SHPF 75 B661 N A N A SHPF 1 0 B841 SHPM 1 0 B863SE SHPF 1 5 B842 SHPM 1 5 B864SE SHPF 2 0 B843 SHPM 2 0 B865SE SHPF 3 0 B844 SHPM 2 5 B866SE SHPM 2 0 2SPD B...

Page 23: ...Page 23 NOTES...

Page 24: ...and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals su...