background image

LIMITED WARRANTY

Thank you for purchasing Jandy

®

 pool and spa products. Water Pik Technologies (manufacturer of Jandy  

products, including Laars

®

 pool and spa heaters, Air Energy Heat Pumps, and Clormatic Electronic Chlorine 

Generators) warrants all parts to be free from manufacturing defects in materials and workmanship for a period of 
one year from the date of retail purchase, with the following exceptions:

• AquaLink

®

 RS units installed with Jandy Surge Protection Kits will be covered for two years.

• NeverLube

®

 valves are warranted for the life of pool and/or spa on which they were originally installed.

• AquaPure

TM

 Electronic Chlorine Generator Electrolytic Cells carry a 5 year limited warranty on a prorated basis.

This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have 
been moved from their original installation sites. The liability of Water Pik Technologies shall not exceed the 
repair or replacement of defective parts and does not include any costs for labor to remove and reinstall the 
defective part, transportation to or from the factory, and any other materials required to make the repair. This 
warranty does not cover failures or malfunctions resulting from the following:

1. Failure to properly install, operate or maintain the product(s) in accordance with our published Installation,

Operation and Maintenance Manuals provided with the product(s).

2. The workmanship of any installer of the product(s).
3. Not maintaining a proper chemical balance in your pool and/or spa [pH level between 7.2 and 7.8, Total

Alkalinity (TA) between 80 to 120 ppm, Total Dissolved Solids (TDS) less than 2000].

4. Abuse, alteration, accident, fire, flood, lightning, rodents, insects, negligence or acts of God.
5. Scaling, freezing, or other conditions causing inadequate water circulation.
6. Operating the product(s) at water flow rates outside the published minimum and maximum specifications.
7. Use of non-factory authorized parts or accessories in conjunction with the product(s).
8. Chemical contamination of combustion air or improper use of sanitizing chemicals, such as introducing

sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer.

9. Overheating, incorrect wire runs; improper electrical supply; collateral damage caused by failure of O-Rings,

DE grids, or cartridge elements; or damage caused by running the pump with insufficient quantities of water.

LIMITATION OF LIABILITY:

This is the only warranty given by Water Pik Technologies. No one is authorized to make any other warranties on 
Water Pik Technologies' behalf. 

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED 

OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF FITNESS FOR A 

PARTICULAR PURPOSE AND MERCHANTABILITY. WATER PIK TECHNOLOGIES EXPRESSLY DISCLAIMS 
AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL, INCIDENTAL, INDIRECT OR PUNITIVE 

DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY.

 This warranty gives you specific 

legal rights. You may also have other rights which vary by state or province.

WARRANTY CLAIMS:

For prompt warranty consideration, contact your dealer and provide the following information: proof of purchase, 
model number, serial number and date of installation. The installer will contact the factory for instructions 
regarding the claim and to determine the location of the nearest designated service center. If the dealer is not 
available, you can locate a service center in your area by visiting www.jandy.com or by calling our technical 
support department at (707) 776-8200 extension 260. All returned parts must have a Returned Material 
Authorization number to be evaluated under the terms of this warranty.

6000 Condor Drive • Moorpark, CA USA 93021

480 S. Service Road West • Oakville, Ontario, Canada L6K 2H4

A Water Pik Technologies Company

 • 707.776.8200 • Fax 707.763.7785
 • 905.844.8233 • Fax 905.844.2635

Litho in U.S.A. © Water Pik Technologies, Inc. 0404

H0230500C

Summary of Contents for SFTM PRO Series

Page 1: ...proper installation and or operation can create unwanted high pressure which can cause serious injury property damage or death Improper installation and or operation will void the warranty WARNING Before installing this product read and follow all warning notices and instructions that accompany this filter Failure to follow warning notices and instructions may result in property damage severe inju...

Page 2: ......

Page 3: ...nd Seasonal Start up 5 4B Normal Operation 6 4C Valve Operation 6 TABLE OF CONTENTS Equipment Information Record Initial Pressure Gauge Reading with clean filter Pump Model Horsepower Filter Model Serial Number Notes SECTION 5 Backwashing the Filter 5A Backwashing 6 5B Filter Disassembly Assembly 7 SECTION 6 Maintenance 6A General Maintenance 7 6B Pressure Gauge 7 SECTION 7 Winterizing the Filter ...

Page 4: ...e sure that the filter is properly mounted and positioned according to these instructions 5 SAVE THESE INSTRUCTIONS SECTION 1 Safety Information 1A Important Safety Warning 1B General Safety Instructions WARNING NEVER OPERATE THIS FILTER SYSTEM AT MORE THAN 50 PSI THIS FILTER OPERATES UNDER HIGH PRESSURE WHEN ANY PART OF THE CIRCULATING SYSTEM i e FILTER PUMP VALVE S CLAMPS ETC IS SERVICED AIR CAN...

Page 5: ...Requirements 1 For best overall performance locate the system as close as possible to the pool 2 The filter should be located on a level concrete slab so that the orientation of the valve outlets are convenient and accessible for the installation and operation of the unit 3 Provide for protection from the weather 4 If fitting a chlorinator and or any other device into the filtration plumbing circu...

Page 6: ...k carton for any damage due to rough handling in shipment If carton or any filter components are damaged notify carrier immediately 2 Carefully remove the accessory package and the filter tank from the carton 3 A visual inspection of all parts should be made now 4 Mount the pressure gauge to the top of the filter Note On top mount filters the pressure gauge mounts into the MPV 5 Install the pressu...

Page 7: ...it a visual inspection of the entire system see Fig 4 5 Position the filter to safely direct water drainage Align the pressure release valve to safely direct purged air or water 6 If the system is to be located above water level it can be raised 2 5 ft without affecting the pump efficiency A check valve is recommended on the suction line to the pump Figure 5 Basic Pool Spa Combination Plumbing Fig...

Page 8: ...tings This will prevent a restriction in the water flow 6 Make all plumbing connections in accordance with local plumbing and building codes Filter connections are provided with an o ring seal Do not use pipe joint compound glue or solvent on bulkhead connections 7 Keep piping tight and free of leaks Pump suction line leaks may cause air to be entrapped in filter tank or loss of prime at the pump ...

Page 9: ...4B Normal Operation 1 With the pump off set MPV handle to Filter position 2 Fill the hair lint pot on the pump with water 3 Open filter pressure release valve stand clear of the filter and turn the pump on 4 When a steady stream of water comes from the pressure release valve close the valve 5 With the filter pump operating record the initial pressure gauge reading in this manual When reading is 10...

Page 10: ...ckwashing the Filter omit this step when first filling a new filter 2 Stop the pump disconnect the power if necessary 3 Open pressure release valve on top of the filter tank to release all air pressure from inside the tank and system On models with a top mounted valve the pressure release valve is on the multiport valve 4 Remove the filter drain plug from the bottom of the tank and drain any water...

Page 11: ...t filter cycles Presence of algae check disinfectant content Check pH and total alkalinity Pump output exceeds design flow rate of filter check pump performance Ineffective backwash check conditions High pressure on start up Small eyeball fitting in Pool Spa Partially closed valve on return line Too large of pump check selection Sand returns to pool line Check that connections into multiport valve...

Page 12: ... T R0355002 6 Collector Tube Lateral Manifold Assembly 2 SF36 T R0355003 7 75mm Lateral 8 SF24 T R0349400 8 110mm Lateral 8 SF24 T R0349500 200mm Lateral 16 not shown SF28 T R0350800 200mm Lateral 16 not shown SF30 T R0350800 75mm Lateral 8 not shown SF32 T R0349400 145mm Lateral 8 not shown SF32 T R0349600 145mm Lateral 16 not shown SF36 T R0349600 9 Lateral End Cap 8 All R0349700 10 Drain Plug A...

Page 13: ...Description Size PART NO 1 Filter Tank SF30 S SF30 S 1 Filter Tank SF36 S SF36 S 2 Lateral 75mm SF30 36 R0349400 3 Lateral 145mm SF30 S R0349600 3a Lateral 200mm not shown SF36 S R0350800 4 Lateral Manifold Assembly SF30 S R0354102 4 Lateral Manifold Assembly SF36 S R0354103 5 Inlet Tube Assembly SF30 S R0354202 5 Inlet Tube Assembly SF36 S R0354203 6 Drain Plug Assembly All R0355100 7 Half Unions...

Page 14: ...Page 14 NOTES ...

Page 15: ......

Page 16: ...rates outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals such as introducing sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer 9 Overheating incorrect wire runs improper electrical supply co...

Reviews: