Page 30
7.2
DIP Switch Settings for
Pool and Spa Combination
DIP Switch #
OFF
ON
1
AUX1= any equipment
AUX1= Pool Cleaner
2
AUX2= any equipment
AUX2= Low Speed for a two-speed filter
pump.
Filter pump circuit becomes High Speed.
3
AUX3= any equipment
AUX3= Spa Spillover effect- Combination
controls only.
4
Heater cool down operates.
Heater cool down disabled.
5
Normal operation
Factory adjustment- when this switch is on,
temperature delays are eliminated and solar
temperature is displayed.
Do not leave this switch in the ON
position.
6
Spare Aux activates with Filter Pump when
Spa OFF.
Activates with Filter pump with Spa on.
7
Spare
No change on Combination or Only
Controls.
8
After thermostat setting has been reached,
heater will remain OFF for 3 minutes.
After thermostat setting has been reached,
heater will remain OFF for 5 minutes.
Factory setting is with all DIP
switches off.