Symptom

Problem

Possible Solution

One button on the Four 
Function Remote does not 
operate.

Check programming first. If 
the Four Function Remote 
is programmed correctly, the 
button may be shorted.

Replace the Four Function Re mote. Use MENU, 
REVIEW, SPA SWITCH to check pro gramming.

Pool cleaner booster pump 
turns on without the filter pump 
being on, and can run with the 
spa on.

System is not recognizing DIP 
switch #1 is on. Note: before 
turning on any DIP switches, 
first turn off all equipment.

Turn off all equipment buttons, then turn off 
power to the system, finally turn off, then on, DIP 
switch #1. Turn on power and test system.

Cannot assign cleaner JVA.

DIP switches not set correctly.

DIP switch #1 must be off, and DIP switch #7 
must be on to assign the cleaner JVA to an 
auxiliary.

System comes on at times that 
are not programmed.

Phantom programs.

At the PDA press MENU, then scroll to REVIEW. 
Make note of all programs (the Four Function 
Remote setting, labels, and temperature 
settings) then turn off all DIP switches and go to 
the PDA. CLEAR MEM ORY, reprogram and try 
system again.

Heater will not fire. Heater LED 
will not light in "Service Mode".

Water temperature sensor not 
installed or defective.

Check water temperature sensor.

LCD screen display stays on 
startup screen.

No communication between 
PDA Handheld Remote and 
Power Center J-box.

Change the Frequency Channel. See Section 
3.8.3.

Summary of Contents for RS-PS6

Page 1: ...s These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not...

Page 2: ......

Page 3: ...0 4 2 Restarting the System Clear Memory Menu 23 4 3 PDA System Defaults and General Modes 23 4 4 PDA Handheld Remote Menu Flow Chart 25 Section 5 Troubleshooting 26 5 1 PDA Quick Troubleshooting Guid...

Page 4: ...regnant or possibly pregnant women should limit spa water temperatures to 100 F 38 C c Before entering a spa or hot tub the user should measure the water temperature with an accurate thermometer since...

Page 5: ...your health Do not permit any electric appliance such as a light telephone radio or television within 5 feet 1 5 m of a spa or hot tub The use of alcohol drugs or medication can greatly increase the r...

Page 6: ...gital Assistant PDA System Sub Assembly Power Centers Sold Separately Standard Power Center with mounting brackets Sub Panel Power Center with mounting brackets and circuit breaker mounting plate Two...

Page 7: ...VAC 1 HP 120 VAC 1500 Watts Incandescent Low Voltage Class Two 1 A 24 VAC Service Switch All Circuits located at Power Center in Service Mode Dimensions Standard Power Center 5 14 13 Sub Panel Power...

Page 8: ...l and spa consult the Jandy Valve Actuator Installation and Operation Manual to ensure that the JVA s are synchronized and rotate properly Please consult the Jandy Valve Plumbing Manual for further ex...

Page 9: ...Filter Pump Pool Intake Spa Intake Spa Return Pool Return Check Valve Spa Make up Booster Pump Filter Filter Pump Pool Intake Spa Intake Spa Return Pool Return Check Valve Spa Make up Energy Filter Cl...

Page 10: ...lack White Primary Low voltage raceway do not run high voltage in this com partment From Main Power Ground White White Black Black Transformer Earth Ground Breaker Panel To 120 VAC Breaker Neutral Bla...

Page 11: ...be controlled connect line power to the two 2 line terminals and connect equipment power to the two 2 load terminals on the same relay For each piece of 120 volt equipment connect power to a line ter...

Page 12: ...2 volt light a 120 volt 12 volt step down AC transformer listed certified for the application must be used For more information about 12 volt installations refer to the Jandy Digital Color Changing Un...

Page 13: ...Page 13 Figure 5 120 Volt Jandy Pool and Spa Light Wiring Diagram Figure 6 12 Volt Jandy Pool and Spa Light Wiring Diagram...

Page 14: ...es are kept from being pinched or damaged CAUTION DO NOT INSTALL BATTERY until ready to power up system 3 3 2 PDA J Box Cable Connection to Power Center PCB Make provision for the cable to be run betw...

Page 15: ...high limit or pressure switches 4 Turn the heater thermostat s to maximum setting 5 Turn the heater switch to the ON position For dual thermostat heaters turn switch to Spa position Figure 9 Lite2 He...

Page 16: ...nction configuration connect the orange black and black orange wires to one contact and the yellow black wire to the other contact see Figure 15 Limit Switch Factory Installed Wire Nut R Limit Switch...

Page 17: ...ndard relay then connect the relay to the solar pump output on the PCB Set the time to 11 59 PM at 12 00 AM the AquaLink RS will auto relabel Solar as Heat Pump Otherwise the AquaLink RS will auto rel...

Page 18: ...nsor Green 10 Pin Terminal Bar NOTE Do not coil the JVA wires inside Power Center To shorten the wire remove the JVA cover and disconnect the wire Shorten strip and reconnect 3 For alternate plumbing...

Page 19: ...or your AquaLink RS PDA system can be changed The Power Center Transceiver and the PDA Transceiver J box must be set to the same RF channel 1 At the Transceiver J box remove the cover to expose the PC...

Page 20: ...light the desired RF channel Then press SELECT 4 When the RF channel is selected the following message appears on the PDA display screen Set slide switch on J Box PCB to the LEARN MODE 5 At the PCB in...

Page 21: ...re 25 Use the UP or DOWN button to highlight either POOL or SPA and press SELECT Use the UP or DOWN button to increase or decrease the temperature and press SELECT Use the BACK button to return to the...

Page 22: ...ce of equipment Highlight a device and press SELECT X means the device has been assigned NOTE The filter pump is always assigned to freeze protection 4 1 6 Assign JVAs Menu Highlight MENU and press SE...

Page 23: ...or pool spa only models Button 2 Spa Heater Temp1 pool spa only models Button 3 AUX1 Button 4 AUX2 Default Freeze Protection Settings FILTER PUMP freeze protection ON ALL OTHER EQUIPMENT freeze protec...

Page 24: ...pecial Note to Startup Person The AquaLink RS PDA allows two 2 options for operating the pool equipment on the first day of operation Option 1 Once all programming of equipment is completed the AquaLi...

Page 25: ...Page 25 4 4 PDA Handheld Remote Menu Flow Chart Items Seen Only With Optional Equipment Mode Only Displayed When DIP Switch 3 is Set to ON...

Page 26: ...the four conductor cable Also check the installation of the PPD on the power center PCB If the PPD is not seated correctly the system will not communicate PDA Handheld Remote backlight is on and the s...

Page 27: ...itch 1 Turn on power and test system Cannot assign cleaner JVA DIP switches not set correctly DIP switch 1 must be off and DIP switch 7 must be on to assign the cleaner JVA to an auxiliary System come...

Page 28: ...Page 28 Section 6 Power Center Wiring Diagram...

Page 29: ...IMPORTANT You must also install a Jandy Two Speed Relay DIP 3 ON AUX 3 Controls Spa Spillover Operates with Pool Spa Combination Turn this switch ON and when the AUX 3 button on the AquaLink RS PDA o...

Page 30: ...down disabled 5 Normal operation Factory adjustment when this switch is on temperature delays are eliminated and solar temperature is displayed Do not leave this switch in the ON position 6 Spare Aux...

Page 31: ...No change 4 Heater cool down operates Heater cool down disabled 5 Normal operation Factory adjustment when this switch is on temperature delays are eliminated and solar temperature is displayed Do not...

Page 32: ...er 1 Sprinkler 2 Sprinkler 3 Stereo Stream Swim Jet Timed Aux Valve s Wtr Feature Whirlpool 1 2 3 Back Basement Beach Bedroom Bug Cabana Color Wheel Deck Dock Drive East Entry Equipment Fan Fence Floo...

Page 33: ...Page 33 NOTES...

Page 34: ...Page 34 NOTES...

Page 35: ......

Page 36: ...r r r r Litho in U S A Waterpik Technologies 0504 H0572200 ETL LISTED CONFORMS TO UL STD 1563 CERTIFIED TO CAN CSA C22 2 NO 218 1 PDA HANDHELD REMOTE FCC ID S8F826X PDA TRANSCEIVER FCC ID S8F8252...

Reviews: