Page 18
6
Remove the button plug from the hole on the
right side of the heater located just below the
entry hole for the power.
7.
Feed the pump wires through the jacket and
connect them to the "Power In" terminals (on the
power circuit board) and the relay terminals as
indicated on the wiring diagram on page 16.
Remember to use the alternate wiring scheme
shown on page 16 when connecting power to a
115 volt source.
8.
Attach the ground wire to one of the green
ground screws located on the back panel of the
power connection box.
9.
Replace the cover of the power connection box
and replace the screws to hold it in place. Be
sure that the power wires and pump wires are
completely enclosed by the cover. Be sure that
the wires are not pinched by the cover.
SECTION 7.
Operating Instructions
7.1 Start-Up
Be sure that there is water in the pool and that
the surface level is above the skimmer or other inlet of
the pool's filter system.
With any new pool or spa installation, operate the
filter pump with the heater off long enough to com-
pletely clean the water. This will remove any installation
residue from the water. Clean the filter at the end of
this operation before starting the heater. When raising
the temperature of a cold pool, program the time clock
to turn the pump off 23 hours and 58 minutes after the
start time ( i.e. If start time is 2:00 PM then set stop
time at 1:58 PM.) This lets the filter system and heater
operate continuously until the water reaches the tem-
perature setting on the temperature control. When that
happens, the heater will automatically shut off, but the
filter pump will keep running.
IMPORTANT:
The temperature controls
cannot be calibrated in the field. If the control is faulty,
shut down the heater by following the procedures in
Section 7.3 and have a qualified service technician
replace the control. DO NOT use the thermostat
switch to completely shut down the heater.
CAUTION
Do not use this heater if any part has been
under water. Immediately call a qualified
service technician to inspect the heater and
replace any part of the control system and any
gas control which has been under water.
ATTENTION
N'utilisez pas cet appareil s'il a été plongé dans
l'eau, même partiellement. Faites inspecter
l'appareil par un technicien qualifié et
remplacez toute partie du système de contrôle
et toute commande qui ont été plongés dans
l'eau.
CAUTION
Should overheating occur or the gas supply fail
to shut off, turn off the manual gas control valve
to the heater.
ATTENTION
En cas de surchauffe ou si l'alimentation en
gaz ne s'arrête pas, fermez manuellement le
robinet d'arrêt de l'admission de gaz.
CAUTION
Do not attempt repairs on the gas controls or
appliance. Tampering is dangerous and voids
all warranties.
CAUTION
Keep all objects off the top of the heater.
Blocking air flow could damage the heater, and
may void the warranty.
WARNING
Vent pipes, draft hoods, and heater tops get
hot! These surfaces can cause serious burns.
Do not touch these surfaces while the heater is
in operation. Adding a vent cap reduces the
temperature on the top.
WARNING
For your safety, when starting the heater, keep
your head and face well away from the lower
firebox opening to prevent any risk of personal
injury.
Summary of Contents for Lite2 LJ Series
Page 45: ...Model LJ Pool and Spa Heater Page 43 NOTES...
Page 46: ...Page 44 NOTES...