background image

LIMITED WARRANTY

Thank you for purchasing Jandy

®

 pool and spa products. Waterpik Technologies (manufacturer of Jandy  

products, including Laars

®

 pool and spa heaters, Air Energy Heat Pumps, and Clormatic Electronic Chlorine 

Generators) warrants all parts to be free from manufacturing defects in materials and workmanship for a period of 
one year from the date of retail purchase, with the following exceptions:

• AquaLink

®

 RS units installed with Jandy Surge Protection Kits will be covered for two years.

• NeverLube

®

 valves are warranted for the life of pool and/or spa on which they were originally installed.

• AquaPure

TM

 Electronic Chlorine Generator Electrolytic Cells carry a 5 year limited warranty on a prorated basis.

This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have 
been moved from their original installation sites. The liability of Waterpik Technologies shall not exceed the repair 
or replacement of defective parts and does not include any costs for labor to remove and reinstall the defective 
part, transportation to or from the factory, and any other materials required to make the repair. This warranty does 
not cover failures or malfunctions resulting from the following:

1. Failure to properly install, operate or maintain the product(s) in accordance with our published Installation,

Operation and Maintenance Manuals provided with the product(s).

2. The workmanship of any installer of the product(s).
3. Not maintaining a proper chemical balance in your pool and/or spa [pH level between 7.2 and 7.8, Total

Alkalinity (TA) between 80 to 120 ppm, Total Dissolved Solids (TDS) less than 2000 not including salt ppm].

4. Abuse, alteration, accident, fire, flood, lightning, rodents, insects, negligence or acts of God.
5. Scaling, freezing, or other conditions causing inadequate water circulation.
6. Operating the product(s) at water flow rates outside the published minimum and maximum specifications.
7. Use of non-factory authorized parts or accessories in conjunction with the product(s).
8. Chemical contamination of combustion air or improper use of sanitizing chemicals, such as introducing

sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer.

9. Overheating; incorrect wire runs; improper electrical supply; collateral damage caused by failure of O-Rings,

DE grids, or cartridge elements; or damage caused by running the pump with insufficient quantities of water.

LIMITATION OF LIABILITY:

This is the only warranty given by Waterpik Technologies. No one is authorized to make any other warranties on 
Waterpik Technologies' behalf. 

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED 

OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF FITNESS FOR A 
PARTICULAR PURPOSE AND MERCHANTABILITY. WATERPIK TECHNOLOGIES EXPRESSLY DISCLAIMS 
AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL, INCIDENTAL, INDIRECT OR PUNITIVE 
DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY.

 This warranty gives you specific 

legal rights. You may also have other rights which vary by state or province.

WARRANTY CLAIMS:

For prompt warranty consideration, contact your dealer and provide the following information: proof of purchase, 
model number, serial number and date of installation. The installer will contact the factory for instructions 
regarding the claim and to determine the location of the nearest designated service center. If the dealer is not 
available, you can locate a service center in your area by visiting www.jandy.com or by calling our technical 
support department at (707) 776-8200 extension 260. All returned parts must have a Returned Material 
Authorization number to be evaluated under the terms of this warranty.

6000 Condor Drive • Moorpark, CA USA 93021

480 S. Service Road West • Oakville, Ontario, Canada L6K 2H4

A Waterpik Technologies Company

 • 707.776.8200 • Fax 707.763.7785
 • 905.844.8233 • Fax 905.844.2635

H0561200A

Litho in U.S.A. © Waterpik Technologies 0410

ETL LISTED

CONFORMS TO

UL STD 676

Summary of Contents for JandyColors JPL120100

Page 1: ...ed by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in property damage serious injury...

Page 2: ......

Page 3: ...9 4 2 Replacing the Light Fixture 9 Section 5 Wiring Options for Controlling Jandy Pool Lights or Jandy Spa Lights 11 5 1 Wiring to an AquaLink RS Control System 11 5 2 Wiring to a Time Clock 12 Secti...

Page 4: ...d which could result in death or serious injury to pool or spa users installers or others due to electrical shock and may also cause damage to property Read and follow the specific instructions below...

Page 5: ...AC 30 feet JPL12030 Jandy Pool Light 120 Volt AC 50 feet JPL12050 Jandy Pool Light 120 Volt AC 100 feet JPL120100 Jandy Pool Light 120 Volt AC 150 feet JPL120150 Jandy Spa Light 12 Volt AC 30 feet JSL...

Page 6: ...r spas c c The light fixture and all metal items within five 5 feet of the pool or spa must be properly The light fixture and all metal items within five 5 feet of the pool or spa must be properly ele...

Page 7: ...ound the light allows the light to be serviced after the pool or spa is filled with water 2 Cut the cord at the Junction Box leaving at least six 6 inches of cord to make connections 3 Strip six 6 inc...

Page 8: ...lly grounds the housing securely to the mounting ring and wet niche Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool or spa use...

Page 9: ...oltage transformer must be located at least The Junction Box or for 12 volt models the low voltage transformer must be located at least 8 inches above ground or water level at least four 4 inches abov...

Page 10: ...ectrical hazard which could result in death or serious injury to pool or spa users installers or others due to electrical shock 3 Remove Junction Box cover disconnect the light fixture wires and strai...

Page 11: ...nization must be operated at the same time to assure color synchronization otherwise the otherwise the lights will work independently of each other lights will work independently of each other 5 1 Wir...

Page 12: ...iring Diagram GFCI Ground Ground Neutral Black White Green 12V Jandy Light Black White Green 120V 12V Transformer 120 VAC Power Supply 5 2 Wiring to a Time Clock The Jandy Pool and Spa Lights can be w...

Page 13: ...Blue will be the first color set in the change sequence when the light is turned on again 6 2 To Lock On a Specific Color Set Wait until the desired color is ON during the first cycle of color change...

Page 14: ...the mounting ring and wet niche Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool or spa users installers or others due to elect...

Page 15: ...ght new bulbs four 4 sets of P N R0399600 for Jandy Pool Light Jandy Pool Light or four 4 sets of or four 4 sets of P N R0400300 for P N R0400300 for Jandy Spa Light Jandy Spa Light Do not touch the b...

Page 16: ...heck to see that the clamp is properly installed around the entire flange It is important to have the screw already started in is properly installed around the entire flange It is important to have th...

Page 17: ...does not recommend installing 12 volt lights with cord lengths greater than 50 feet A significant voltage drop will occur that dramatically reduces the light output and possibly unit failure Wires fro...

Page 18: ...t 3 N A Bulb Holder and Electronics Assembly Pool NO Purchase New Light 4 R0399600 Bulb Kit 75 Watt Halogen MR 16 EYC 2 bulbs in kit 8 bulbs required per light YES 5 R0399700 Dichroic Lens Holder Asse...

Page 19: ...tronics Assembly Spa NO Purchase New Light 4 R0400300 Bulb Kit 25 Watt Halogen G 4 Capsule 12 Volt AC 2 bulbs per kit 8 bulbs required per light YES 5 R0400400 Dichroic Lens Holder Assembly Spa YES 6...

Page 20: ...es outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or imprope...