Page 15
4. Disassemble the light
fi
xture and replace bulbs. Use the following bulb removal instructions for Jandy
Pool and Spa Light:
a.
a. Loosen the Phillips head screw on the band clamp to allow the clamp to be removed. Screw should
Loosen the Phillips head screw on the band clamp to allow the clamp to be removed. Screw should
be loosened, but not removed to prevent loss of parts and ease of assembly.
be loosened, but not removed to prevent loss of parts and ease of assembly.
b.
b. Remove the band clamp, bezel face ring, glass lens and gasket from the housing. Remove the
Remove the band clamp, bezel face ring, glass lens and gasket from the housing. Remove the
gasket from the lens. Refer to
gasket from the lens. Refer to
Section 9, Exploded Views and Replacement Parts
Section 9, Exploded Views and Replacement Parts
..
c.
c. Remove the two Phillips hex head Dichroic Lens holder Plate retaining screws.
Remove the two Phillips hex head Dichroic Lens holder Plate retaining screws.
d.
d. Carefully remove the Dichroic Lens Plate. The eight bulbs can now be removed. Discard the
Carefully remove the Dichroic Lens Plate. The eight bulbs can now be removed. Discard the
bulbs.
bulbs.
e.
e. Install eight new bulbs (four (4) sets of P/N R0399600 for
Install eight new bulbs (four (4) sets of P/N R0399600 for
Jandy Pool Light
Jandy Pool Light
or four (4) sets of
or four (4) sets of
P/N R0400300 for
P/N R0400300 for
Jandy Spa Light
Jandy Spa Light
). Do not touch the bulb surface with bare hands, as this can
). Do not touch the bulb surface with bare hands, as this can
dramatically reduce bulb life. Repeat procedure for each bulb.
dramatically reduce bulb life. Repeat procedure for each bulb.
f.
f. Re-position the Lens Plate over the bulbs.
Re-position the Lens Plate over the bulbs.
g.
g. Install the two Lens Plate retaining screws. Do not over-tighten.
Install the two Lens Plate retaining screws. Do not over-tighten.
Power
Cord
Niche
Spa Light
Assembly
Spa
Wall
Mounting
Screw
Positioning
Tab
Tab
Locator
2 Push up on bottom of
light
assembly.
1 Pull top of light assembly
away from spa wall.
Figure 6. Removing the Light Assembly for Bulb Replacement
WARNING
Risk of Electrical Shock or Electrocution.
Always install a new lens gasket whenever
disassembling the light (for
Jandy Pool Light Gasket
P/N R0399800 and for
Jandy Spa Light
Gasket
P/N R0400500). Failure to do so may permit water to leak into the assembly, which could
cause:
(a) An electrical hazard resulting in death or serious injury to pool or spa users, installers, or others
due to electrical shock, or
(b) Breakage of the bulb or lens, which likewise could result in serious injury to pool or spa users,
installers, or bystanders, or in damage to property.
Summary of Contents for JandyColors JPL120100
Page 2: ......