background image

Page 15

4.     Disassemble the light 

fi

 xture and replace bulbs. Use the following bulb removal instructions for Jandy 

Pool and Spa Light:

a.

a.   Loosen the Phillips head screw on the band clamp to allow the clamp to be removed.  Screw should 

Loosen the Phillips head screw on the band clamp to allow the clamp to be removed.  Screw should 
be loosened, but not removed to prevent loss of parts and ease of assembly.

be loosened, but not removed to prevent loss of parts and ease of assembly.

b.

b.   Remove the band clamp, bezel face ring, glass lens and gasket from the housing.  Remove the 

Remove the band clamp, bezel face ring, glass lens and gasket from the housing.  Remove the 
gasket from the lens.  Refer to 

gasket from the lens.  Refer to 

Section 9, Exploded Views and Replacement Parts

Section 9, Exploded Views and Replacement Parts

..

c.

c.   Remove the two Phillips hex head Dichroic Lens holder Plate retaining screws.

Remove the two Phillips hex head Dichroic Lens holder Plate retaining screws.

d.

d.   Carefully remove the Dichroic Lens Plate.  The eight bulbs can now be removed.  Discard the 

Carefully remove the Dichroic Lens Plate.  The eight bulbs can now be removed.  Discard the 
bulbs.

bulbs.

e.

e.   Install eight new bulbs (four (4) sets of P/N R0399600 for 

Install eight new bulbs (four (4) sets of P/N R0399600 for 

Jandy Pool Light

Jandy Pool Light

 or four (4) sets of 

 or four (4) sets of 

P/N R0400300 for 

P/N R0400300 for 

Jandy Spa Light

Jandy Spa Light

).  Do not touch the bulb surface with bare hands, as this can 

).  Do not touch the bulb surface with bare hands, as this can 

dramatically reduce bulb life.  Repeat procedure for each bulb.

dramatically reduce bulb life.  Repeat procedure for each bulb.

f.

f.   Re-position the Lens Plate over the bulbs.

Re-position the Lens Plate over the bulbs.

g.

g.   Install the two Lens Plate retaining screws. Do not over-tighten.

Install the two Lens Plate retaining screws. Do not over-tighten.  

Power 

Cord

Niche

Spa Light 

Assembly

Spa 

Wall

Mounting 

Screw

Positioning 

Tab

Tab 

Locator

2  Push up on bottom of

    light

 

assembly.

1  Pull top of light assembly

    away from spa wall.

Figure 6.  Removing the Light Assembly for Bulb Replacement

  WARNING

Risk of Electrical Shock or Electrocution.

  Always install a new lens gasket whenever 

disassembling the light (for

 Jandy Pool Light Gasket 

P/N R0399800 and for 

Jandy Spa Light 

Gasket 

P/N R0400500). Failure to do so may permit water to leak into the assembly, which could 

cause:  

(a)  An electrical hazard resulting in death or serious injury to pool or spa users, installers, or others 
due to electrical shock, or 

(b)  Breakage of the bulb or lens, which likewise could result in serious injury to pool or spa users, 
installers, or bystanders, or in damage to property.

Summary of Contents for JandyColors JPL120100

Page 1: ...ed by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in property damage serious injury...

Page 2: ......

Page 3: ...9 4 2 Replacing the Light Fixture 9 Section 5 Wiring Options for Controlling Jandy Pool Lights or Jandy Spa Lights 11 5 1 Wiring to an AquaLink RS Control System 11 5 2 Wiring to a Time Clock 12 Secti...

Page 4: ...d which could result in death or serious injury to pool or spa users installers or others due to electrical shock and may also cause damage to property Read and follow the specific instructions below...

Page 5: ...AC 30 feet JPL12030 Jandy Pool Light 120 Volt AC 50 feet JPL12050 Jandy Pool Light 120 Volt AC 100 feet JPL120100 Jandy Pool Light 120 Volt AC 150 feet JPL120150 Jandy Spa Light 12 Volt AC 30 feet JSL...

Page 6: ...r spas c c The light fixture and all metal items within five 5 feet of the pool or spa must be properly The light fixture and all metal items within five 5 feet of the pool or spa must be properly ele...

Page 7: ...ound the light allows the light to be serviced after the pool or spa is filled with water 2 Cut the cord at the Junction Box leaving at least six 6 inches of cord to make connections 3 Strip six 6 inc...

Page 8: ...lly grounds the housing securely to the mounting ring and wet niche Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool or spa use...

Page 9: ...oltage transformer must be located at least The Junction Box or for 12 volt models the low voltage transformer must be located at least 8 inches above ground or water level at least four 4 inches abov...

Page 10: ...ectrical hazard which could result in death or serious injury to pool or spa users installers or others due to electrical shock 3 Remove Junction Box cover disconnect the light fixture wires and strai...

Page 11: ...nization must be operated at the same time to assure color synchronization otherwise the otherwise the lights will work independently of each other lights will work independently of each other 5 1 Wir...

Page 12: ...iring Diagram GFCI Ground Ground Neutral Black White Green 12V Jandy Light Black White Green 120V 12V Transformer 120 VAC Power Supply 5 2 Wiring to a Time Clock The Jandy Pool and Spa Lights can be w...

Page 13: ...Blue will be the first color set in the change sequence when the light is turned on again 6 2 To Lock On a Specific Color Set Wait until the desired color is ON during the first cycle of color change...

Page 14: ...the mounting ring and wet niche Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool or spa users installers or others due to elect...

Page 15: ...ght new bulbs four 4 sets of P N R0399600 for Jandy Pool Light Jandy Pool Light or four 4 sets of or four 4 sets of P N R0400300 for P N R0400300 for Jandy Spa Light Jandy Spa Light Do not touch the b...

Page 16: ...heck to see that the clamp is properly installed around the entire flange It is important to have the screw already started in is properly installed around the entire flange It is important to have th...

Page 17: ...does not recommend installing 12 volt lights with cord lengths greater than 50 feet A significant voltage drop will occur that dramatically reduces the light output and possibly unit failure Wires fro...

Page 18: ...t 3 N A Bulb Holder and Electronics Assembly Pool NO Purchase New Light 4 R0399600 Bulb Kit 75 Watt Halogen MR 16 EYC 2 bulbs in kit 8 bulbs required per light YES 5 R0399700 Dichroic Lens Holder Asse...

Page 19: ...tronics Assembly Spa NO Purchase New Light 4 R0400300 Bulb Kit 25 Watt Halogen G 4 Capsule 12 Volt AC 2 bulbs per kit 8 bulbs required per light YES 5 R0400400 Dichroic Lens Holder Assembly Spa YES 6...

Page 20: ...es outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or imprope...