SECTION 3. Installation Instructions

5

Figure 3. Basic Pool/Spa Combination Plumbing

c.  Orient  the  gauge/air  release  assembly  in  the     
desired      position.  Raise  and  thread  the  locknut  onto 
the  bottom  of  the  gauge/air  release  assembly.  Hand 
tighten the nut only. Using a wrench to tighten the nut 
may damage the nut, gauge or air release assembly. 

5.  To  reduce  pressure  losses,  2"  (minimum)  piping  is    
recommended for plumbing the system.

6. For best efficiency use the fewest possible number of   
fittings. This will prevent a restriction in the water flow.

7.  Make  all  plumbing  connections  in  accordance  with    
local  plumbing  and  building  codes.  Filter  connections    
are  provided  with  an  o-ring  seal.  To  avoid  damage  to     
the o-rings, use only a silicone base lubricant on the   o-
rings. Do not use pipe joint compound, glue or solvent 
on inlet/outlet coupling nuts.

8.  Keep  piping  tight  and  free  of  leaks.  Pump  suction    
line leaks may cause air to be entrapped in filter tank or 
loss of prime at the pump. Pump discharge line   leaks 
may show up as dampness or jets of water.

9.  Support  the  inlet/outlet  pipes  independently  to      
prevent any undue strains on the filter MPV.

10.  Connect  the  pipes  using  the  unions  supplied  with    
the  MPV.  Do  not  use  teflon  tape  or  pipe  dope  on  any     
unions. Assemble the unions dry and hand tighten.

11. Be sure that all provisions for waste water disposal   
meet  local,  state  or  national  codes.  One  hundred    
gallons or more of pool water will be discharged during   
filter  backwashing.  Do  not  discharge  water  where  it    
will cause flooding or damage. 

Laars Heater

Waterfall

Spa Return

Pool Return

Spa Make Up

Jandy 
Check
Valve

Outlet Port

Inlet
Port

Jandy 
Filter

Jandy Pump

From Pool Drain

(Optional)

From Pool Skimmer

Spa Suction

Figure 4. Filter Location

Housing

O-Ring

O-Ring

Tank Adapter

Tank Adapter to Housing
Coupler

Summary of Contents for DEL Series Filters

Page 1: ...and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Improper installation and or operation can create dangerous high pressure which can c...

Page 2: ...p Installation 6 SECTION 4 Start up and Operation 4 1 Preparing Diatomaceous Earth 7 4 2 Coating the Filter Grids 7 4 3 New Pool and Seasonal Start up 8 4 4 Valve Operation 8 SECTION 5 Filter Disassem...

Page 3: ...rt up and Operation 4 Maintain the circulation system properly Replace worn or damaged parts immediately 5 Be sure that the filter is properly mounted and positioned according to these installation in...

Page 4: ...nce locate the filter as close as possible to the pool 2 The filter should be located on a level concrete slab so that the orientation of the valve outlets and pressure gauge are convenient and access...

Page 5: ...remove the accessory package 3 With the carton in an upright position remove the filter tank from the carton 4 A visual inspection of all parts should be made now See parts list on pages 14 and 15 3...

Page 6: ...lvent on inlet outlet coupling nuts 8 Keep piping tight and free of leaks Pump suction line leaks may cause air to be entrapped in filter tank or loss of prime at the pump Pump discharge line leaks ma...

Page 7: ...p ring halves touch each other or are within 1 16 See Fig 6 but do not overtighten as the clamp can break If unable to tighten as indicated do not operate the filter and call a service technician imme...

Page 8: ...o the word DIRTY on the bezel of the gauge This indicates an increased pressure of between 10 and 12 psi above original starting pressure WARNING NEVER start pump while standing within five 5 feet of...

Page 9: ...me and the pressure will increase When the needle of the pressure gauge aligns with the arrow next to the word DIRTY on the bezel ring it is time to backwash the filter see Section 6 2 4 4 Valve Opera...

Page 10: ...sive wear Replace if necessary 8 Assemble the manifold to the top of the assembly Make sure that the grids and outlet tube fit securely into the manifold and that the retaining rod extends up through...

Page 11: ...ter Follow instructions in Section 5 1 4 Using a garden hose thoroughly flush all contaminates from the filter grid surfaces 5 See Section 5 2 for reassembly of the filter tank and filter grids 6 5 Cl...

Page 12: ...ump impeller vanes blocked Pump operating under speed low voltage Presence of algae clogging filter Incorrect water chemistry Strainer baskets not being used and or broken Allows debris into pump Pump...

Page 13: ...utlet Tube Elbow Assembly w O rings DEL48 15 Bulkhead Assembly w O ring Coupling Nuts w Flange and O ring set of 2 Inlet Elbow w O ring DEL6 Tank Bottom w Drain Plug Drain Plug w O ring DE Grid Suppor...

Page 14: ...SECTION 10 Head Loss Curves 13 10 1 Jandy DEL Filter Design Head Loss Curves...

Page 15: ...rranty given by Laars and Jandy No one is authorized to make any other warranties on Laars and Jandy behalf THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITE...

Reviews: