background image

Page 1 0

C artridge Pool Filters -  C L and C V  S eries Filters

3.5 Clamp Installation

1. 

Be certain the o-ring is in position in the lower 

tank half. Press the filter lid over the lower half 

sandwiching the o-ring between the two halves.

2.  Holding the ends of the filter clamp apart, position 

the hinged segment of the filter clamp over both 

upper and lower tank flanges. Bring the ends of the 

filter clamp together.

3.  Place the "T" nut and threaded rod assembly into 

the clamp. Be sure the "T" nut is seated in the 

clamp in the proper orientation (See Fig. 9).

4.  Use a 9/16" socket on the tightening nut until the 

clamp ring halves touch each other, or are within 

1/16" (See Fig. 9) 

but do not overtighten as the 

clamp can break

. If unable to tighten as indicated, 

do not operate the filter and 

call a service 

technician immediately

.

5.  After the first week of operation, check the clamp 

and retighten if necessary.

6.  Check the filter clamp at least once a month. 

Figure 9 .  

Filter C lamp Ring

Cl a m p  R i n g

" T "  N u t  a n d  
T h r e a d e d  R o d

T i g h t e n i n g  N u t  
w /  S h o u l d e r

2.  Check that the drain plug for CL filters or drain 

cap for CV filters is in place and tight.

3. 

Check that the tank clamp is correctly seated and 
tight (See Figs. 9 and 10).

4.  Open the pump hair/lint pot lid and fill the pump  

basket with water to prime the system. Replace the 
lid. (You may have to do this several times on new 
and seasonal start-ups.)

5. 

Completely open the air release valve on the 

gauge/air release assembly by turning the knob on 

the back of the assembly fully counterclockwise 
(do not remove the knob).

6.  Be sure to open any filter isolation valves that 

were installed in the system.

7. 

Stand clear of the filter 

and start the pump to 

circulate water through the system. When a steady 
stream of water starts to come out of the air release 
valve, close the valve.

8. 

Watch the pressure gauge to be sure that the 
pressure does not exceed 50 psi (with clean 
cartridges). If the pressure approaches 50 psi, 
immediately turn the pump off and clean the 

filter cartridges (see Section 6.3). If the pressure 

remains high after cleaning the filter, refer to the 

troubleshooting guide in Section 8 for possible 
causes and solutions.

           W A RN I N G

F o l l o w  t h e se

 i n st r u ct i o n s  ca

r e f u l l y .  

I m p r o p e r  cl a m p  i n st a l l a t i o n  ca

n  ca

u se

 

t h e  f i l t e r  l i d  t o  b e  b l o w n  o f f ,  w h i ch

 c a n  

r e su

l t  i n  d e a t h ,  se

r i o u s  p e r so

n a l  i n j u r y ,  

o r  p r o p e r t y  d a m a g e .

 C A U T I O N

DO  N O T

 o p e r a t e  f i l t e r  a t  w a t e r  t e m p e r a t u r e s  a b o ve

 

105° F (40.6° C). Water temperatures above the 

m a n u f a ct u r e r ' s  r e co

m m e n d a t i o n s  w i l l  sh

o r t e n  t h e  

l i f e  sp

a n  o f  t h e  f i l t e r  a n d  vo

i d  t h e  w a r r a n t y .

          W A RN I N G

N E V E R

 st a r t  p u m p  w h i l e  st a n d i n g  

within five (5) feet of the filter. Starting 

t h e  p u m p  w h i l e  t h e r e  i s  p r e ssu

r i ze

d  a i r  

i n  t h e  syst

e m  ca

n  ca

u se

 t h e  f i l t e r  l i d  t o  

b e  b l o w n  o f f ,  w h i ch

 ca

n  ca

u se

 d e a t h ,  

se

r i o u s  p e r so

n a l  i n j u r y  o r  p r o p e r t y 

d a m a g e .

 W A RN I N G

N E V E R

 o p e r a t e  t h e  f i l t e r  syst

e m  a t  

more than 50 psi of pressure. Operating 

the filter system in excess of 50 psi can 

ca

u se

 t h e  f i l t e r  l i d  t o  b e  b l o w n  o f f ,  w h i ch

 

ca

n  ca

u se

 d e a t h ,  se

r i o u s  p e r so

n a l  i n j u r y 

o r  p r o p e r t y  d a m a g e .

Section 4. Start-Up and Operation

N O T E

 

T h i s  se

ct i o n  a p p l i e s  t o  b o t h  n e w  p o o l  a n d  

se

a so

n a l  st a r t - u p .

1. 

Turn off the pump. Switch off the circuit breaker 
to the pump motor.

Summary of Contents for CV Versa-Plumb Series

Page 1: ...llation and or operation can create dangerous high pressure which can cause the filter lid to b e b lown off possib ly c ausing death serious inj ury or property damage I mproper installation and or o...

Page 2: ......

Page 3: ...ments 5 2 4 Specifications and Dimensions 5 Section 3 Installation Instructions 6 3 1 Filter Location 6 3 2 Anchor Bracket Installation 6 3 3 Filter Preparation 6 3 4 Filter Plumbing 7 3 5 Clamp Insta...

Page 4: ...b l o w n o f f w h i ch ca n r e su l t i n d e a t h se r i o u s p e r so n a l i n j u r y o r p r o p e r t y d a m a g e T o a vo i d t h i s p o t e n t i a l h a za r d f o l l o w a l l o f...

Page 5: ...ll performance place the system as close to the pool as possible 2 The filter should be located on a level concrete slab so that the orientation of the valve outlets and the pressure gauge are conveni...

Page 6: ...g codes require that all appliances be securely fastened to the equipment pad in order to withstand high wind pressures created by hurricanes Jandy provides an anchor bracket kit for this purpose Plea...

Page 7: ...r t o t h e syst e m i s t u r n e d o f f b e f o r e a p p r o a ch i n g i n sp e ct i n g o r t r o u b l e sh o o t i n g a n y l e a ki n g va l ve s o r p l u m b i n g t h a t m a y h a ve ca...

Page 8: ...n d y F i l t e r Figure 5 A C V C artridge Filter Plumb ing for Pool S pa C omb ination Ja n d y H e a t e r W a t e r f a l l P o o l R e t u r n S p a M a ke U p S p a R e t u r n F r o m P o o l...

Page 9: ...flow 6 Make all plumbing connections in accordance with local plumbing and building codes Filter connections are provided with an o ring seal To avoid damage to the o rings use only a silicone base l...

Page 10: ...ter through the system When a steady stream of water starts to come out of the air release valve close the valve 8 Watch the pressure gauge to be sure that the pressure does not exceed 50 psi with cle...

Page 11: ...g it straight up until it clears the cartridges on the inside of the tank 8 Remove the manifold assembly by lifting it off of the outlet tube and out of the tank 9 Pull the cartridges out of the filte...

Page 12: ...o o d w o r ki n g o r d e r T h e p r e ssu r e g a u g e i s t h e p r i m a r y i n d i ca t o r o f h o w t h e f i l t e r i s o p e r a t i n g Section 7 Winterizing 1 Turn off the pump and cir...

Page 13: ...n o r r e p l a c e f i l t e r c a r t r i d g e s p e r i n s t r u c t i o n s F i l l p o o l s o l e v e l i s a b o v e p u m p i n l e t l i n e F i l l p u m p w i t h w a t e r a t b a s k e...

Page 14: ...11 T a n k Cl a m p R i n g w R o d A sse m b l y A l l R0357400 12 T h r e a d e d R o d a n d R e t a i n e r A l l R0357500 13 T a n k O r i n g A l l R0357800 14 O u t l e t T u b e E l b o w A ss...

Page 15: ...5 C artridge Pool Filters C L and C V S eries Filters 19 21 21 20 21 15 21 21 18 21 14 23 19 22 20 22 22 15 22 14 23 16 16 22 18 21 22 9 2 Jandy CL and CV Filters Exploded View CL F i l t e r CV F i l...

Page 16: ...ction 10 Head Loss Curves 10 1 Jandy CL and CV Cartridge Filter Design Head Loss Curves 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 0 30 60 90 120 150 Flow Rate gpm Design Head Loss ft head 0 2 4 6 8 10 1...

Page 17: ...Page 1 7 N o t e s C artridge Pool Filters C L and C V S eries Filters...

Page 18: ...Page 1 8 N o t e s C artridge Pool Filters C L and C V S eries Filters...

Page 19: ...Page 1 9 N o t e s C artridge Pool Filters C L and C V S eries Filters...

Page 20: ...o n s 7 U se o f n o n f a ct o r y a u t h o r i ze d p a r t s o r a cce sso r i e s i n co n j u n ct i o n w i t h t h e p r o d u ct s 8 Ch e m i ca l co n t a m i n a t i o n o f co m b u st i o...

Reviews: