   Installation & Operation Manual

Figure 2.  Pressure Gauge and Pressure Release 

Assembly

Air Release Valve

Pressure Gauge

Pressure Gauge

Adapter

Clean/Dirty Snap Ring

 WARNING

Water discharged from an improperly positioned filter 

or valve can create an electrical hazard which can 

cause death, serious injury or property damage.

CAUTION

Maintain your pressure gauge in good working order. 

The pressure gauge is the primary indicator of how the 

filter is operating.

5. 

Allow sufficient space above the filter to remove 

the filter lid and filter element for cleaning and 

servicing.

6. 

Position the filter to safely direct water drainage. 

Align the air release valve to safely direct purged 

air or water.

7. 

If the filter is to be installed below the water level 

of the pool, isolation valves should be installed on 

both the suction and return lines to prevent back 

flow of pool water during any routine servicing 

that may be required.

3.2  Filter Preparation

1. 

Check carton for damage due to rough handling 

in shipment. If carton or any filter components are 

damaged, notify carrier immediately.

2. 

Carefully remove the accessory package. Remove 

the filter tank from the carton. 

3. 

A visual inspection of all parts should be made 

now. See parts list in Section 9.

4. 

Install the pressure gauge and adapter assembly to 

the threaded hole marked "Pressure Gauge" at the 

top of the filter See Fig. 2. 

5. 

Install the air release valve into the threaded 

opening marked "Air Release" at the top of the 

filter. See Fig. 2.

NOTE

  Teflon tape is included in the accessory bag.

3.3  Filter Installation

 WARNING

To avoid an electrical shock hazard, which can result 

in serious injury or death, ensure that all electrical 

power to the system is turned off before approaching, 

inspecting or troubleshooting any leaking valves or 

plumbing that may have caused other electrical devices 

in the surrounding area to get wet.

1. 

This filter operates under pressure. When the 

locking ring is properly seated and the filter is 

operated without air in the water system, this filter 

will operate in a safe manner.

2. 

If the system can be subjected to higher pressures 

than the maximum working pressure of the lowest 

rated component, install an ASME

®

 approved 

automatic Pressure Relief Valve or Pressure 

Regulator in the circulation system.

3. 

Place the filter on the concrete pad, lined up with 

the inlet and outlet pipes.

4. 

To reduce pressure losses, 2" (minimum) piping 

is recommended for plumbing the system. 

Never exceed the manufacturer's maximum 

recommended filter flow rates.

5. 

For best efficiency use the fewest possible 

number of fittings. This will prevent a restriction 

of the water flow.

6. 

Make all plumbing connections in accordance 

with local plumbing and building codes. Filter 

unions are provided with an o-ring seal. Use 

silicone based lubricants on the o-rings to avoid 

damage. 

Do not use pipe joint compound, glue 

or solvent on union threads.

7. 

Keep piping tight and free of leaks. Pump suction 

line leaks may cause air to be entrapped in filter 

tank or loss of prime at the pump. Pump discharge 

line leaks may show up as equipment pad leaks or 

air being discharged through the return lines.

Figure 1.  Filter Location - Top View

Filter

12" Minimum 

Clearance

6" Minimum Clearance

Drain

Summary of Contents for CS150

Page 1: ...follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper installation...

Page 2: ......

Page 3: ...lation Instructions 5 3 1 Filter Location 5 3 3 Filter Installation 6 3 4 Locking Ring Tank Top Assembly Installation 7 Section 4 Start Up and Operation 8 4 1 New Pool and Seasonal Start up 8 Section...

Page 4: ...Y INSTRUCTIONS Check all clamps bolts lids lock rings and system accessories to ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing Water pressur...

Page 5: ...or any other device into the filtration plumbing circuit great care must be exercised to ensure that the appliance is installed in accordance with the Manufacturer s Instructions and any applicable s...

Page 6: ...r See Fig 2 NOTE Teflon tape is included in the accessory bag 3 3 Filter Installation WARNING To avoid an electrical shock hazard which can result in serious injury or death ensure that all electrical...

Page 7: ...the equipment pad with a masonry bit Use the holes in the tank bottom base as a guide 11 Install x 2 Stainless Steel Tapcon screws and tighten 3 4 Locking Ring Tank Top Assembly Installation WARNING F...

Page 8: ...ON DO NOT operate filter at water temperatures above 105 F 40 6 C Water temperatures above the manufacturer s recommendations will shorten the life span of the filter and void the warranty 4 1 New Poo...

Page 9: ...service technician 5 Product safety signs or labels should be periodically inspected and cleaned by the product user as necessary to maintain good legibility for safe viewing 6 Product safety signs or...

Page 10: ...any filter isolation valves to prevent flooding 3 Open the air release valve on top of the filter and wait for all air pressure to be released 4 Loosen the drain plug at the base of the filter to ensu...

Page 11: ...t line Fill pump with water at basket and replace lid Technician required Technician or electrician required Short filter cycles Presence of algae clogging filter Incorrect water chemistry Strainer ba...

Page 12: ...50 Sq Ft CS250 R0462500 5 Tailpiece Cap and Union Nut Set Set of 3 2 x 2 1 2 R0461800 5 Tailpiece Cap and Union Nut Set Set of 3 50mm R0462600 6 Breather Tube CS100 CS150 R0462801 6 Breather Tube CS20...

Page 13: ...200 250 Normal Start Up PSI 6 15 6 15 6 15 6 15 Max Working PSI 50 50 50 50 Residential Specifications Maximum Flow gpm 100 125 125 125 6 Hour Capacity gallons 36 000 45 000 45 000 45 000 8 Hour Capac...

Page 14: ...ter Installation Operation Manual 18 1 2 3 1 4 A 14 3 4 Figure 7 Dimensions CS Cartridge Series Filter Figure 8 Dimensions CS Cartridge Series Filter Top View Outlet Port Inlet Port Drain Port 13 20 1...

Page 15: ...Page 15 ENGLISH Jandy Pro Series CS Single Element Cartridge Pool Spa Filter Installation Operation Manual NOTES...

Page 16: ...Inc 2 3365 Mainway Burlington Ontario L7M 1A6 1 888 647 4004 www ZodiacPoolSystems ca 2018 Zodiac Pool Systems LLC ZODIAC is a registered trademark of Zodiac International S A S U used under license A...

Reviews: