Troubleshooting Guide

Fault Symptom

Possible Problems

Solutions

Water is not clear.

Insufficient disinfectant level.
Incorrect pool chemistry.
Heavy bathing and/or dirt loads.
Insufficient running times.
Filter is dirty.
Hole in filter element.

Check and adjust disinfectant level.
Test and adjust water chemistry.
Adjust filter time and/or water chemistry.
Increase pump run time.
Clean filter per instructions.
Replace filter cartridge.

Low water flow.

Filter system strainer baskets dirty.
Air leaks on suction side of pump. 

Restrictions or blockage in either 

suction or return lines.
Filter cartridge needs to be cleaned or 

replaced.  
Pool water level too low.
Pump not primed.
Pump impeller vanes blocked.
Pump operating under speed (low 

voltage).

Check and clean strainer baskets.
Check all connections between pool 

intake and pump.
Check all lines for debris or partially 

closed valves.
Clean or replace filter cartridge per 

instructions.
Fill pool so level is above pump inlet line.
Fill pump with water at basket and replace 

lid.
Technician required.
Technician or electrician required.

Short filter cycles.

Presence of algae clogging filter.
Incorrect water chemistry.
Strainer baskets not being used and/or 

broken. (Allow debris into pump.)
Pump output exceeds design flow rate 

of filter.
Ineffective cleaning.

Check disinfectant content.
Check pH, total alkalinity and TDS.
Replace baskets. 

Check pump performance. 

Clean or replace filter cartridge per 

instructions.

High pressure on start-up.

Small eyeball fitting in Pool/Spa.
Partially closed valve on return line.
Too large of pump.
Filter cartridge dirty.

Replace with larger diameter fitting.
Check and fully open all valves on return 

line.
Check pump and filter selection.
Clean filter cartridge per instructions.

Dirt returns to pool.

Hole in filter cartridge.
Worn o-ring seal inside filter.
Filter not assembled correctly.

Replace filter cartridge per instructions.
Replace o-ring.
Reassemble filter per instructions.

Section 8.  Troubleshooting

1. 

For a list of common problems and solutions see the Troubleshooting Guide below.

2. 

Zodiac recommends that you call a qualified service technician to do any work on the filter/pump system. For 

technical assistance, contact our Technical Support Department at 1.800.822.7933.

Summary of Contents for CS150

Page 1: ...follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper installation...

Page 2: ......

Page 3: ...lation Instructions 5 3 1 Filter Location 5 3 3 Filter Installation 6 3 4 Locking Ring Tank Top Assembly Installation 7 Section 4 Start Up and Operation 8 4 1 New Pool and Seasonal Start up 8 Section...

Page 4: ...Y INSTRUCTIONS Check all clamps bolts lids lock rings and system accessories to ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing Water pressur...

Page 5: ...or any other device into the filtration plumbing circuit great care must be exercised to ensure that the appliance is installed in accordance with the Manufacturer s Instructions and any applicable s...

Page 6: ...r See Fig 2 NOTE Teflon tape is included in the accessory bag 3 3 Filter Installation WARNING To avoid an electrical shock hazard which can result in serious injury or death ensure that all electrical...

Page 7: ...the equipment pad with a masonry bit Use the holes in the tank bottom base as a guide 11 Install x 2 Stainless Steel Tapcon screws and tighten 3 4 Locking Ring Tank Top Assembly Installation WARNING F...

Page 8: ...ON DO NOT operate filter at water temperatures above 105 F 40 6 C Water temperatures above the manufacturer s recommendations will shorten the life span of the filter and void the warranty 4 1 New Poo...

Page 9: ...service technician 5 Product safety signs or labels should be periodically inspected and cleaned by the product user as necessary to maintain good legibility for safe viewing 6 Product safety signs or...

Page 10: ...any filter isolation valves to prevent flooding 3 Open the air release valve on top of the filter and wait for all air pressure to be released 4 Loosen the drain plug at the base of the filter to ensu...

Page 11: ...t line Fill pump with water at basket and replace lid Technician required Technician or electrician required Short filter cycles Presence of algae clogging filter Incorrect water chemistry Strainer ba...

Page 12: ...50 Sq Ft CS250 R0462500 5 Tailpiece Cap and Union Nut Set Set of 3 2 x 2 1 2 R0461800 5 Tailpiece Cap and Union Nut Set Set of 3 50mm R0462600 6 Breather Tube CS100 CS150 R0462801 6 Breather Tube CS20...

Page 13: ...200 250 Normal Start Up PSI 6 15 6 15 6 15 6 15 Max Working PSI 50 50 50 50 Residential Specifications Maximum Flow gpm 100 125 125 125 6 Hour Capacity gallons 36 000 45 000 45 000 45 000 8 Hour Capac...

Page 14: ...ter Installation Operation Manual 18 1 2 3 1 4 A 14 3 4 Figure 7 Dimensions CS Cartridge Series Filter Figure 8 Dimensions CS Cartridge Series Filter Top View Outlet Port Inlet Port Drain Port 13 20 1...

Page 15: ...Page 15 ENGLISH Jandy Pro Series CS Single Element Cartridge Pool Spa Filter Installation Operation Manual NOTES...

Page 16: ...Inc 2 3365 Mainway Burlington Ontario L7M 1A6 1 888 647 4004 www ZodiacPoolSystems ca 2018 Zodiac Pool Systems LLC ZODIAC is a registered trademark of Zodiac International S A S U used under license A...

Reviews: