Page 6
Cartridge Pool Filters - CL and CV Series Filters
Section 3. Installation Instructions
3.1 Filter Location
6HOHFWDZHOOGUDLQHGDUHDRQHWKDWGRHVQRWÀRRG
when it rains. Damp, non-ventilated areas should
be avoided.
3URYLGHVROLGPRXQWLQJIRUWKH¿OWHUDQGSXPS
system. Install system on a concrete slab or solid
concrete blocks to avoid risk of settlement. Do not
XVHVDQGWROHYHOWKH¿OWHUDVWKHVDQGZLOOZDVK
away. Filter systems can weigh up to 800 lbs.
,QVWDOOHOHFWULFDOFRQWUROVDWOHDVW¿YHIHHWIURP
WKH¿OWHU7KLVZLOODOORZHQRXJKURRPWRVWDQG
DZD\IURPWKH¿OWHUGXULQJVWDUWXS
$OORZVXI¿FLHQWFOHDUDQFHDURXQGWKH¿OWHUWR
permit a visual inspection of the clamp ring (see
Fig. 2).
$OORZVXI¿FLHQWVSDFHDERYHWKH¿OWHUWRUHPRYH
WKH¿OWHUOLGDQG¿OWHUHOHPHQWIRUFOHDQLQJDQG
servicing.
3RVLWLRQWKH¿OWHUWRVDIHO\GLUHFWZDWHUGUDLQDJH
Align the air release valve to safely direct purged
air or water.
FILTER
Figure 2.
Filter Location
0,1,080
CLEARANCE
0,1,080&/($5$1&(
CAUTION
Maintain your pressure gauge in good working
order. The pressure gauge is the primary indicator
of how the filter is operating.
WARNING
Water discharged from an improperly positioned
filter or valve can create an electrical hazard
which can cause death, serious injury or property
damage.
,IWKH¿OWHUQHHGVWREHORFDWHGDERYHWKHZDWHU
level of the pool, it can be raised 2.5 ft. without
DIIHFWLQJWKHSXPSHI¿FLHQF\$FKHFNYDOYHLV
recommended on the suction line to the pump.
,IWKH¿OWHULVWREHLQVWDOOHGEHORZWKHZDWHUOHYHO
of the pool, isolation valves should be installed on
both the suction and return lines to prevent back
ÀRZRISRROZDWHUGXULQJDQ\URXWLQHVHUYLFLQJ
that may be required.
3.2 Anchor Bracket Installation
In some areas, for example Florida, building codes
require that all appliances be securely fastened to the
equipment pad in order to withstand high wind pressures
created by hurricanes. Jandy provides an anchor bracket
kit for this purpose. Please see the Parts List in Section
9 of this manual for the correct part number. Follow the
Anchor Bracket Installation Kit Instructions to attach
WKHEUDFNHWVWRWKH¿OWHU
NOTE
Anchor screws and washers for securing the
anchor bracket to the equipment pad are not
LQFOXGHGZLWKWKH¿OWHURUWKHDQFKRUEUDFNHW
kit. Jandy recommends that a ¼" x 2¼" long
stainless steel Tapcon
®
concrete screw and
VWDLQOHVVVWHHOÀDWZDVKHUDUHXVHGWRPRXQW
each anchor bracket to the equipment pad. The
Tapcon concrete screw meets Florida building
code requirements.
$IWHUSODFLQJWKH¿OWHURQWKHHTXLSPHQWSDGDVRXWOLQHG
LQ6HFWLRQGULOODKROHLQWKHFRQFUHWHDW
HDFKRIWKHIRXUEUDFNHWVRQWKH¿OWHU7KHFRUUHFWVL]H
concrete drill bit should be obtained when the concrete
screws are purchased.)
Install the Tapcon
®
screws and washers through each
RIWKHIRXUDQFKRUEUDFNHWVWRVHFXUHWKH¿OWHUWRWKH
equipment pad. See Figure 3.
Do not over-torque the
screws
.
3.3 Filter Preparation
1.
Check carton for damage due to rough handling
LQVKLSPHQW,IFDUWRQRUDQ\¿OWHUFRPSRQHQWVDUH
damaged, notify carrier immediately.
2.
Carefully remove the accessory package.
3.
A visual inspection of all parts should be made
now. See parts list in Section 9.
4.
With the carton in an upright position, remove the
¿OWHUWDQNIURPWKHFDUWRQ
7RPRXQWWKHSUHVVXUHJDXJHDLUUHOHDVHDVVHPEO\
WRWKHWRSRIWKH¿OWHUWDQNORFDWHGLQWKHDFFHVVRU\
bag):
a.
Place the smaller, thicker o-ring onto the
threads of the tank adapter (see Figure 4).
Slide the tank adapter through the coupling
WARNING
Use equipment only in a pool or spa installation.
Do not connect system to an unregulated city water
system or other external source of pressurized
ZDWHUSURGXFLQJSUHVVXUHVJUHDWHUWKDQSVL