Page 5
Cartridge Pool Filters - CL and CV Series Filters
Section 2. General Information
2.1 Introduction
This manual contains information for the proper instal-
lation and operation of the Jandy
®
CL and CV Series
Cartridge Filters. Procedures in this manual must be
followed exactly. To obtain additional copies of this
manual contact us at 707.776.8200 ext. 237. For address
information see back cover.
2.2 Description
&DUWULGJH¿OWHUVGRQRWUHTXLUHVDQGRUGLDWRPDFHRXV
HDUWKDVWKH¿OWHUPHGLXP,QVWHDGWKH¿OWHUFRQWDLQV
¿OWHUHOHPHQWVZKLFKDUHHDVLO\UHPRYHGIRUFOHDQLQJRU
replacement.
'LUW\ZDWHUÀRZVLQWRWKH¿OWHUWDQNWKURXJKWKHZDWHU
line connected to the lower bulkhead (inlet) on the
bottom half of the tank body. It is directed through the
¿OWHUFDUWULGJHLQVLGHRIWKH¿OWHU7KHGHEULVLVFROOHFWHG
LQWKH¿OWHUDQGWKHFOHDQZDWHUÀRZVRXWRIWKH¿OWHU
through the upper bulkhead (outlet) on the bottom half
of the tank body. Clean water is returned through the
piping system to the pool.
$VGHEULVFROOHFWVLQWKH¿OWHUWKHSUHVVXUHZLOOULVH
DQGZDWHUÀRZWRWKHSRROZLOOGLPLQLVK7KH¿OWHUZLOO
eventually become so plugged with debris that it will be
QHFHVVDU\WRUHPRYHWKH¿OWHUFDUWULGJHVDQGFOHDQWKHP
with soap and water.
NOTE
$¿OWHUUHPRYHVGLUWDQGRWKHUVXVSHQGHGSDUWLFOHV
but does not sanitize the pool. Pool water must be
sanitized and chemically balanced for clear water.
7KH¿OWUDWLRQV\VWHPVKRXOGEHGHVLJQHGWRPHHW
local health codes. At a minimum, the system should
turnover the total volume of water in your pool two to
IRXUWLPHVLQDKRXUSHULRG
2.3 General Requirements
1.
For best overall performance place the system as
close to the pool as possible.
7KH¿OWHUVKRXOGEHORFDWHGRQDOHYHOFRQFUHWH
slab so that the orientation of the valve outlets and
the pressure gauge are convenient and accessible
for the installation and operation of the unit.
3URWHFWWKH¿OWHUIURPWKHZHDWKHU
,I¿WWLQJDFKORULQDWRUDQGRUDQ\RWKHUGHYLFHLQWR
WKH¿OWUDWLRQSOXPELQJFLUFXLWJUHDWFDUHPXVWEH
exercised to ensure that the appliance is installed
in accordance with the Manufacturer’s Instructions
and any standards that may exist.
5.
We recommend the use of barrel unions to connect
each component of the water conditioning system
to ease in future servicing. Barrel unions are
SURYLGHGZLWKDOO-DQG\¿OWHUV
CL/CV
340
460
580
Filter Area (ft
2
)
Max. Flow (gpm)
127
Six Hour
Capacity (gal.)
Max. Working
Pressure (psi)
Normal Start Up
Pressure (psi)
Dimension "A"
LQ
LQ
LQ
7DEOH
&DUWULGJH)LOWHU6SHFL¿FDWLRQV
Figure 1.
Dimensions, Jandy CL and CV Series
Cartridge Filters
WARNING
7KHPD[LPXPRSHUDWLQJSUHVVXUHIRUWKLVILOWHULV
psi. Never subject the filter to operating pressure
H[FHHGLQJSVL2SHUDWLQJSUHVVXUHVDERYHSVL
can cause the lid to be blown off, which can result in
death, serious personal injury, or property damage.
6.
When performing hydrostatic pressure tests or
when testing for external leaks of the completed
¿OWUDWLRQDQGSOXPELQJV\VWHPHQVXUHWKDW
WKHPD[LPXPSUHVVXUHWKH¿OWUDWLRQV\VWHPLV
subjected to
does not exceed the maximum
working pressure of any of the components
within the system.
6SHFL¿FDWLRQVDQG'LPHQVLRQV
See Table 1 and Figure 1.
18 ½ in
10 ½ in
28 in
"A"
CL INLET
OUTLET
CV INLET
Port on
CV Model
Only
Port on
CL Model
Only