background image

Page 4

3.  Remove the white cap covering the comm hole  

(see Figure 6). 

4.  Thread the controller cable through the hole. A 

grommet may be necessary depending on the size of 

the cable being used.

5.  Attach a cable tie to the controller cable as shown 

(see Figure 6).  

6

.  The Jandy

 

AquaLink

®

 RS or PDA and power pack 

 

use a four (4) wire connection to communicate 

and can be wired up to 500 ft (152.4 m) apart. 

Any outdoor rated four conductor cable, minimum 

22 AWG (0.33 mm

2

), can be used. Locate the 

appropriate screw terminals on the circuit board and 

wire the power pack

  

to the AquaLink

  

RS or PDA 

red 4-pin terminal bar (see Figure 7).

NOTE

  The screw terminals on the AquaLink RS or 

PDA are removable to aid in installation.

D.  Testing the Connection

Once the power pack has been wired to the AquaLink 

RS Control System or PDA, follow these steps to test 

the connection:

1.  Apply power to the power pack and the AquaLink 

RS Control System or PDA. 

2.  Wait about 20 seconds. If the connection was 

successful, a 

Ŧ 

symbol will appear in the top right 

corner of the power pack display. 

NOTE

  If the power pack does not connect to the 

controller, turn the power off to both devices 

and repeat steps 1 and 2. If the power pack 

still does not connect to the controller, re-check 

the wiring connections (see Figure 7) and 

the controller setting on the power pack (see 

Section 4.B).

Figure 7. 

Communication Wiring between Power 

Pack and AquaLink RS Control System 

or PDA Network

Jandy

Power Center

Power Pack

OPTIONAL

4 3 2 1

RED

BLK

YEL

GRN

Red, 4-Pin

Terminal Bar

RED

GRN

YEL
BLK

B

A

0V

POS

RED

BLK

  © 2010 Zodiac Pool Systems, Inc. All rights reserved. 0110

ZODIAC POOL SYSTEMS, INC.

2620 Commerce Way • Vista, CA • 92081 

Tel: 800-822-7933 • Fax: 877-327-1403

H0342800 Rev -

ETL Listed

Conforms To 

UL STD 1081

Certified to 

CAN/CSA C22.2 NO. 218.1