background image

Page 15

3.4 

Heater Connection

The heater connection section applies to all 

heaters or heat pumps with thermostatic circuitry 

of 24 VAC or less (see pages 15 thru 17 for brand 

specific installation).

NOTE 

If you are connecting a heater with thermostatic 

circuitry of 120 VAC or greater, do not connect 

to the green, 10-pin Terminal Bar. Instead, 

connect the heater to a high voltage relay in 

the Power Center and plug the spare relay into 

the Electric Heater relay socket located on the 

upper right hand corner of the Power Center 

PCB.

3.4.1  Jandy Brand Heater Connections

1.  Connect two #14 gauge wires, designed for 

use in hot environments, to the #1 and #2 

terminals on the green, 10-pin Terminal Bar.

2.  Connect the other ends of the #14 gauge 

wires from Step 1 to the Fireman's Switch 

terminal bar in place of the factory installed 

wire loop. 

3.  Do not disconnect high limit or pressure 

switches.

4.  Turn the heater thermostat(s) to maximum 

setting.

5.  Turn the heater switch to the ON position. 

For dual thermostat heaters turn switch to 

Spa position.

Figure 9.  lite2 Heater Connection

Power Center PCB/Bezel

Heater 

Wiring

#14 

Gauge 

Wire

Green 10-pin 

Terminal Bar

Heater 

Thermostat To 

Max.

Heater Toggle 

Switch To On

Terminal 1

Terminal 2

Heater Fireman's Switch 

Connection

Factory 

Installed

Wire loop

3.4.2  Guidelines for Sophisticated Diagnostic 

Communication to LX Heaters

1.  Remove the LX GUI from the heater.

2.  Confirm the LX and AquaLink RS software 

revisions are compatible (see table).

3.  Run a 4-conductor cable from the LX GUI 

red, 4-pin connector to the RS power Center 

red, 4-pin connector (see Figure 10).

lX Software Revision

Aqualink RS Software 

Revision

C10, C11 or later

PDA 1.0 or later

NOTE 

If connecting more than two (2) items to the RS 

Power Center red, -pin connector, a Multiplex 

PCB is required.

OPTIONAL

4 3 2 1

4

3

2

1

RED

BLK

YEL

GRN

R

E

D

B

L

K

Y

E

L

G

R

N

4-Conductor 

Wire 

lX GUI

RS Power 

Center

Figure 10.  lX Heater Connection to Power Center

PDA

J-box

Summary of Contents for AquaLink RS PDA

Page 1: ...s These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not...

Page 2: ......

Page 3: ...4 2 Restarting the System Clear Memory Menu 23 4 3 PDA System Defaults and General Modes 23 4 4 PDA Handheld Remote Menu Flow Chart 25 Section 5 Troubleshooting 26 5 1 PDA Quick Troubleshooting Guide...

Page 4: ...egnant or possibly pregnant women should limit spa water temperatures to 100 F 38 C c Before entering a spa or hot tub the user should measure the water temperature with an accurate thermometer since...

Page 5: ...ur health Do not permit any electric appliance such as a light telephone radio or television within 5 feet 1 5 m of a spa or hot tub The use of alcohol drugs or medication can greatly increase the ris...

Page 6: ...ital Assistant PDA System Sub Assembly Power Centers Sold Separately Standard Power Center with mounting brackets Sub Panel Power Center with mounting brackets and circuit breaker mounting plate Two 2...

Page 7: ...Watts Incandescent Low Voltage Class Two 1 A 24 VAC Service Switch All Circuits located at Power Center in Service Mode Dimensions Standard Power Center 5 14 13 Sub Panel Power Center 20 14 5 Note Br...

Page 8: ...etween pool and spa consult the Jandy Valve Actuator Installation and Operation Manual to ensure that the JVAs are synchronized and rotate properly Please consult the Jandy Valve Plumbing Manual for f...

Page 9: ...ilter Pump Pool Intake Spa Intake Spa Return Pool Return Check Valve Spa Make up Booster Pump 2 3 3 Non Booster Pump Pool Cleaner Plumbing Filter Filter Pump Pool Intake Spa Intake Spa Return Pool Ret...

Page 10: ...Power Center Filter Pump Relay Aux 3 Relay Transformer Earth Ground Black White Primary Low voltage raceway do not run high voltage in this compartment From Main Power Ground White White Black Black F...

Page 11: ...the two 2 line terminals and connect equipment power to the two 2 load terminals on the same relay For each piece of 120 volt equipment connect power to a line terminal and connect equipment to a load...

Page 12: ...lling a 12 volt light a 120 volt 12 volt step down AC transformer listed certified for the application must be used For more information about 12 volt installations refer to the Jandy Digital Color Ch...

Page 13: ...C Power Supply Junction Box Figure 5 120 Volt Jandy Pool and Spa Light Wiring Diagram Figure 6 12 Volt Jandy Pool and Spa Light Wiring Diagram GFCI Ground Ground Neutral Black White Green 12V Jandy Li...

Page 14: ...es are kept from being pinched or damaged CAUTION DO NOT INSTALL BATTERY until ready to power up system 3 3 2 PDA J Box Cable Connection to Power Center PCB Make provision for the cable to be run betw...

Page 15: ...ure switches 4 Turn the heater thermostat s to maximum setting 5 Turn the heater switch to the ON position For dual thermostat heaters turn switch to Spa position Figure 9 Lite2 Heater Connection Powe...

Page 16: ...ction configuration connect the orange black and black orange wires to one contact and the yellow black wire to the other contact see Figure 15 Limit Switch Factory Installed Wire Nut R Limit Switch R...

Page 17: ...solar pump output on the PCB Set the time to 11 59 PM at 12 00 AM the AquaLink RS will auto relabel Solar as Heat Pump Otherwise the AquaLink RS will auto relabel Solar as Heat Pump within 24 hours 5...

Page 18: ...n 10 Pin Terminal Bar 10 9 8 7 6 5 4 3 2 1 Note Do not coil the JVA wires inside Power Center To shorten the wire remove the JVA cover and disconnect the wire Shorten strip and reconnect 3 For alterna...

Page 19: ...ceiver and the PDA Transceiver J box must be set to the same RF channel 1 At the Transceiver J box remove the cover to expose the PCB see Figure 20 Figure 20 PDA Transceiver J Box Internal View 2 On t...

Page 20: ...e LEARN MODE 5 At the PCB in the Transceiver J box slide the Learn Switch to LEARN ON See Figure 22 SET RF CHANNEL RF CHANNEL 1 Use ARROW KEYS to set the RF CHANNEL Press SELECT to continue Pool Digit...

Page 21: ...TUP Pool Digital Assistant 1 2 select back PDA SET TEMP POOL HEAT 80 F SPA HEAT 104 F Highlight an item and press SELECT Pool Digital Assistant 1 2 select back PDA SET TEMP POOL HEAT 80 F SPA HEAT 104...

Page 22: ...ERAL LABELS LIGHT LABELS WTRFALL LABELS CUSTOM LABEL Pool Digital Assistant 1 2 select back PDA LABEL AUX1 GENERAL LABELS AUX1 AERATOR AIR BLOWER BACKWASH BOOSTER PUMP CHEM FEED CLEANER MORE Pool Digi...

Page 23: ...MEMORY ERASING ALL SETTINGS please wait Figure 30 Clear Memory Menu 4 3 PDA System Defaults and General Modes Default Temperature Pool Spa Combination Default Pool Temp 80 F Default Spa Temp 102 F Def...

Page 24: ...ws two 2 options for operating the pool equipment on the first day of operation Option 1 Once all programming of equipment is completed the AquaLink RS PDA will automatically review all programs and t...

Page 25: ...CTION AIR TEMP DEGREES F C ENABLED DISABLED FAHRENHEIT CELCIUS SET TEMP PUMP LOCKOUT ENABLED DISABLED BOOST SET AQUAPURE SET OUTPUT AQUAPURE SET TIME HELP SERVICE DIAGNOSTICS START GO BACK EQUIPMENT O...

Page 26: ...to the transceiver J box Also check the installation of the PPD on the power center PCB If the PPD is not seated correctly the system will not communicate PDA Handheld Remote backlight is on and the...

Page 27: ...ches first turn off all equipment Do not program any auxiliaries until all DIP switches are set Turn off all equipment buttons then turn off power to the system finally turn off then on DIP switch 1 T...

Page 28: ...minal bar To Sensors etc green terminal bar To Controller red terminal bar 4 3 2 1 6 5 4 3 2 1 Blue Red Black Red Black F Pump Aux 2 Aux 3 Aux 6 Aux 5 Aux 4 Relay Sockets 24 VDC output JVA Sockets 24...

Page 29: ...ow speed IMPORTANT You must also install a Jandy Two Speed Relay DIP 3 ON AUX 3 Controls Spa Spillover Operates with Pool Spa Combination Turn this switch ON and when the AUX 3 button on the AquaLink...

Page 30: ...Normal operation Factory adjustment when this switch is on temperature delays are eliminated and solar temperature is displayed Do not leave this switch in the ON position 6 Spare Aux activates with F...

Page 31: ...No change 4 Heater cool down operates Heater cool down disabled 5 Normal operation Factory adjustment when this switch is on temperature delays are eliminated and solar temperature is displayed Do not...

Page 32: ...1 Sprinkler 2 Sprinkler 3 Stereo Stream Swim Jet Timed Aux Valve s Wtr Feature Whirlpool 1 2 3 Back Basement Beach Bedroom Bug Cabana Color Wheel Deck Dock Drive East Entry Equipment Fan Fence Flood F...

Page 33: ...Page 33 NOTES...

Page 34: ...Page 34 NOTES...

Page 35: ......

Page 36: ...or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals such as introducing sanitizing chemicals upstream of the heater and...

Reviews: