Page 31
3.
The maintain temperature delay is used when
MAINTAIN TEMP
is connected
.
This feature
allows for a time delay before the pump is turned
on. To select Maintain Temperature Delay, use the
Up
or
Down
button to scroll through to display
MAINTAIN TEMP DELAY
. Press the
MENU
button. The
00:30 HRS
(default time) appears,
use the
Up
or
Down
button to scroll to display
the desired time delay, press the
MENU
button
to select
.
Press
POOL
or
SPA
to exit the Service
Setup mode.
7.3.3 Remote
Refer to Section 4.5.2.3, Configure the Control
Panel.
7.3.4 Defrost
Selection
1.
Make sure the control is in the
OFF
mode.
2.
To enter the Service Setup mode, press and hold
the
MENU, POOL
and
SPA
button for 5 seconds.
NOTE
The display will revert back to OFF after one
minute since the last key press.
3.
This feature allows for defrost mode using air
or hot gas. To select Defrost Selection, use the
Up
or
Down
button to scroll through to display
DEFROST
. Press the
MENU
button. The
AIR
DEFROST
(default mode) appears, use the
Up
or
Down
button to scroll to display the desired
defrost option, press the
MENU
button to select
.
Press
POOL
or
SPA
to exit the Service Setup
mode.
7.3.5 Test
Mode
1.
Make sure the control is in the
OFF
mode.
2.
To enter the Service Setup mode, press and hold
the
MENU, POOL
and
SPA
button for 5 seconds.
NOTE
The display will revert back to OFF after one
minute since the last key press.
3.
If enabled, this feature reduces delay settings by a
factor of 20. To select Test Mode, use the
Up
or
Down
button to scroll through to display
TEST
MODE
. Press the
MENU
button. The
DISABLE
(default mode) appears, use the
Up
or
Down
button to scroll to display the desired test mode,
press the
MENU
button to select
.
Press
POOL
or
SPA
to exit the Service Setup mode.
CAUTION
Disable
TEST MODE
after use. Failure to
disable
TEST MODE
after use will allow the
heat pump to bypass the built-in delays, which
could lead to equipment damage
.
NOTE
The
TEST MODE
resets to
DISABLE
(default)
on every power-up.
7.3.6 Load
Defaults
1.
Make sure the control is in the
OFF
mode.
2.
To enter the Service Setup mode, press and hold
the
MENU, POOL
and
SPA
button for 5 seconds.
NOTE
The display will revert back to OFF after one
minute since the last key press.
3.
This feature allows for original factory settings
to be restored. To select Load Defaults, use the
Up
or
Down
button to scroll through to display
LOAD DEFAULTS
. Press the
MENU
button. The
NO
(default mode) appears, use the
Up
or
Down
button to scroll to display the desired option, press
the
MENU
button to select
.
Press
POOL
or
SPA
to exit the Service Setup mode.
NOTE
The
LOAD DEFAULTS
resets to
NO
(default)
after
execution.
7.3.7
Coil Temperature Calibration
1.
Make sure the control is in the
OFF
mode.
2.
To enter the Service Setup mode, press and hold
the
MENU, POOL
and
SPA
button for 5 seconds.
NOTE
The display will revert back to OFF after one
minute since the last key press.
3.
This feature adjusts the temperature reading in
the heat pump coil. To select Coil Temperature
Calibration, use the
Up
or
Down
button to scroll
through to display
COIL TEMP CAL
. Press the
MENU
button. The
0°F
(default mode) appears,
use the
Up
or
Down
button to scroll to display the
desired temperature adjustment, press the
MENU
button to select
.
Press
POOL
or
SPA
to exit the
Service Setup mode.