IS183-17E
J&D Manufacturing • 6200 Hwy 12 • Eau Claire, WI 54701 • 1-800-998-2398 • www.jdmfg.com
Page 3/4
4”
4”
On the mounting flange measure and mark 4” from each of the 14
pre-drilled mounting holes used for attaching the shutter clips as shown.
5
Using marks made in
Step 5
as your guide secure housing to structure
using hardware suitable for your structure (not included) and washers
compatible with your hardware (not included).
DO NOT secure through the sidewalls of the housing
DO NOT distort the housing
Venturi must not be distorted and prop must be able to rotate freely
and not come in contact with the housing
6
Venturi must not
be distorted and
prop must be
able to rotate
freely and not
come in contact
with the housing
Connecting power to the unit.
• Install manual disconnect switch inside building adjacent
to fan.
• Route wire to motor with drip loop and secure. Drip loop
will drain accumulated moisture away from the motor.
• Configure internal wires to match supply voltage and
wire according to motor nameplate. Test to verify correct
rotation.
• Shut off manual disconnect for remainder of
install. Only permit power to unit when shutter
and guard is fully installed to prevent injury.
7
DISCONNECT POWER
BEFORE INSTALLING OR SERVICING.
ALL ELECTRICAL WORK SHOULD BE COMPLETED BY
QUALIFIED PERSONNEL AND MEET NATIONAL (NEC),
REGIONAL AND LOCAL ELECTRIC CODES.
!
!
Swivel top and side shutter clips open. Set bottom shutter flange between
housing flange and bottom shutter clips. Secure shutter by swiveling top
and side shutter clips over shutter flange.
8