SAFETY PRECAUTIONS

Keep it away from children!

This appliance can be used by children aged from 8 years and above if they have been given 

supervision or instruction concerning use of the appliance in a safe way and if they understand the 

hazards involved. Cleaning and user maintenance shall not be made by children unless they are 

aged 8 years and above and supervised. Keep the appliance and its cord out of reach of children 

aged less than 8 years.

• 

Please store the ultrasonic cleaner where it is inaccessible by children.

• 

Danger to children! Danger for death through suffocation! Keep packaging material away from children.

• 

This appliance should not be used by children. Keep the appliance and its cord out of reach of children.

To prevent life-threatening electrical shock, please observe the following:
Danger of electrical shock!  

Do not use while bathing. Never immerse the device or the power cord 

in water or other liquid.

•  Danger of electrical shock! 

 Never touch the power plug with wet hands, especially when inserting or 

removing the plug.

•  Danger of electrical shock! 

 If the unit has fallen into water during operation, do not touch the unit. 

Remove the power plug from the socket first.

•  Danger of electrical shock! 

  Do not spray water or liquid over the device.

• 

Never operate the device unattended.

• 

Follow the manual to operate the device.

• 

Do not use components unapproved by the manufacturer.

• 

When removing the power cord from the socket, grab the power plug not the cord.

• 

To protect the power cord from damage, do not cause it to get caught by things such as cupboard door or 

a chair leg; do not drag across a hot surface.

• 

If there is damage to the power plug, cord, housing, or other parts of the device, do not use the device.

• 

Do not disassemble the device, except by professionals.

• 

If the unit is damaged, non-operational or has fallen into water, take it to a qualified service provider.

• 

Remove the power plug from the socket:
-if malfunction occurs
-before cleaning the device
-if the device is not going to be used for prolonged period
-after each use (recommended)

• 

The installation of an earth leakage circuit breaker with a rated tripping current of no more than 30 mA 

provides further protection against an electrical shock. The installation should only be carried out by a 

trained electrician.

To prevent fire hazards, please observe the following:

• 

Never block the vents on the device. Keep the vents free from lint, hair and other materials.

• 

Do not place the device on a soft surface, such as a bed or a couch, where the vents could be blocked.

• 

Observe the other warnings in the previous section.

• 

If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly 

qualified person in order to avoid a hazard.

1

Summary of Contents for ULTRA 9020

Page 1: ...rature thermometer degas and solution usage timer Independent control circuit 40 higher efficiency not susceptible to for each ultrasonic transducer interference more durable Multiple circuit protecto...

Page 2: ...4 Suspendible basket to drain water conveniently 2 x industrial grade ultrasonic transducers 2 x 55 W 110 W 2 x ceramic heaters 2 x 80 W 160 W 3 x colour LED display 1 to 30 minute full range timer 5...

Page 3: ...perate the device unattended Follow the manual to operate the device Do not use components unapproved by the manufacturer When removing the power cord from the socket grab the power plug not the cord...

Page 4: ...fore servicing or cleaning To reduce the risk of electrical shock do not put the appliance in water or other liquid Do not place or store appliance where it can fall or be pulled into a tub or sink Al...

Page 5: ...easily remove the debris 3 Biology Chemical Laboratories Labs can use ultrasonic cleaners to clean test tubes and other glass or metal containers to remove residual chemicals and debris that can affec...

Page 6: ...raditional methods 9 Special Education Institutes Kindergartens Speech therapy tools or small toys that are reused need to be cleaned to prevent the growth and spread of bacteria Ultrasonic cleaning c...

Page 7: ...ands shavers or razors Ultrasonic cleaning can clean the debris in the crevices It is quick and convenient This model has a large tank When cleaning small items the Indirect Cleaning method can be use...

Page 8: ...gears valves tools fuel injectors etc BABY ITEMS Toys baby items speech therapy tools etc SILVER COPPER OR BRASS Silverware silver copper or brass decorations etc LAB ITEMS Test tubes beakers flasks...

Page 9: ...e pipe fitting E Drainage valve handle F Control panel G Handles H Power switch I Power socket J Cover holder Indirect cleaning tank Size 21 7x18 5x7 4 cm Capacity 2 1 L Internal size 19 8x16 6x7 35 c...

Page 10: ...8 PRODUCT EXPLODED VIEW...

Page 11: ...l valve Standard part 23 Bracket ABS 24 Valve handle ABS 25 Elbow ABS 26 Inner tank ABS 27 Bottom cover ABS 28 Power PCB 1 94Vo 29 Power PCB 2 94Vo 30 Right cover ABS 31 Right down handle ABS 32 Right...

Page 12: ...ater button again dims indicating the heater is turned off 10 Working Status Green Ready G Normal working status ready to use Red Overheat R Under overheat protection 20 minutes or more of waiting tim...

Page 13: ...ton to select the temperature in the following sequence 40 C or 104 F 45 C or 113 F 50 C or 122 F 55 C or 131 F 60 C or 140 F 17 Timer Quick Set Button Press Time button LED display shows Each pressin...

Page 14: ...ower switch on Press Time button to set the timer to 10 minutes Press On Off button to start cleaning Ultrasonic waves will penetrate the container and clean the items NOTE Optional stainless steel in...

Page 15: ...r brass cartridges 3 Turn the power switch on Press Temp button to set the water temperature to 50 C 122 F Press Heater button to turn on the heater flashes Close the lid LED lights up indicating the...

Page 16: ...utes Common cleaning times are 5 10 or 15 minutes Prolonged cleaning time may result in a Loosening of the screws if used b Increasing pre existing cracks c Peeling of coating which was already separa...

Page 17: ...o speed up the mixing and to use less solution use degas function Press TIME button to set the timer to 10 minutes then press Function button illuminates Press On Off to start degassing It changes ove...

Page 18: ...r approximately 15 minutes respectively to ensure safety The unit will be disabled until it is repaired Do not run the unit for extended time or continuously The unit is designed with overheat protect...

Page 19: ...direct cleaning SPECIFICATIONS Description Professional Ultrasonic Cleaner Model ULTRA 9020 Tank Capacity 6 0 L Max 5 0 L 1 3 gallon US 1 6 gallon US Min 3 35 L 0 9 gallon US Tank Size 32 3 x 20 5 x...

Page 20: ...g your unit please call our Returns Department on 44 0 1258 822516 for a RMA Returns Materials Authorisation number Please return your unit in its original packaging along with a covering letter stati...