1.
– Digital LED Working Time Display.
It counts down after work is started.
2.
– Water temperature indicator
Solid green light indicates that the water temperature
is 0-30% of the set temperature.
Solid orange light indicates that the water temperature is 30-60%
of the set temperature.
Solid red light indicates that the water temperature is 60-90% of the set
temperature. Flashing red light indicates that the water temperature is close to the set temperature.
All lights on, indicate that the water temperature is at the set temperature (90-100%).
3. – Set Temperature Display.
Press Temp button to select one of the 5 set temperatures.
40°C or 104°F 45°C or 113°F 50°C or 122°F 55°C or 131°F 60°C or 140°F
4. – °C or °F Indicator.
°C - Set temperature in °C. – ° F - Set temperature in °F.
5. – Solution usage remaining time.
It counts down to show the remaining usage time
(hour : minute) of the solution.
6. – Solution Warning Light.
Once the Solution Usage Timer is set, the light will come up. The light will
flash when the solution needs changing.
7. – Degas Status.
Illuminated, the degas function is selected.
Flashing, degassing is underway.
8.
– Heater Status.
Press Heater button, flashes, indicating the heater is turned on. Press Heater
button again, dims, indicating the heater is turned off.
9.
– Normal Cleaning Status.
– Illuminated, normal cleaning is underway.
10. Working Status.
Green - Ready (G): Normal working status, ready to use.
Red - Overheat (R): Under overheat protection. 20 minutes or more of waiting time is needed for the light
to change from red to green. Work can resume afterwards.
11. Function Button.
Press function button,
illuminates, indicating Degas function is selected. Press On/
Off button to start degassing.
will flash for 2 minutes, then the unit will return to the normal cleaning
function. Pressing Function button before it ends will stop degassing. If additional degassing is needed
after it ends, then press Function button again.
Degas:
When cleaning heavily soiled or greasy items or silver, copper or brass items, chemical
solutions need to be added into the water. The solution may form many small droplets and take a
long time to dissolve in the water. Newly added water may generate many air bubbles on the tank
walls. These will reduce the cleaning effect in the beginning phase of ultrasonic cleaning. Turning
on the degas function will dissipate the droplets and the air bubbles, usually in 90 seconds, and
improve cleaning efficiency.
12. Temperature Set Button.
5 set temperatures can be selected. Press Temp button to select the temperature
in the following sequence:
40°C or 104°F 45°C or 113°F 50°C or 122°F 55°C or 131°F 60°C or 140°F
11
CONTROL PANEL AND OPERATIONS