background image

1.   

   – Digital LED Working Time Display. 

It counts down after work is started.

2. 

  – Water temperature indicator  

 

Solid green light indicates that the water temperature 

is 0-30% of the set temperature.  

 Solid orange light indicates that the water temperature is 30-60% 

of the set temperature. 

 Solid red light indicates that the water temperature is 60-90% of the set 

temperature.   Flashing red light indicates that the water temperature is close to the set temperature.  

All lights on, indicate that the water temperature is at the set temperature (90-100%).

3.            – Set Temperature Display. 

Press Temp button to select one of the 5 set temperatures. 

    40°C or 104°F   45°C or 113°F   50°C or 122°F   55°C or 131°F   60°C or 140°F 

4.         – °C or °F Indicator.

 

°C - Set temperature in °C.    –   ° F  - Set temperature in °F.

5.           – Solution usage remaining time. 

It counts down to show the remaining usage time  

(hour : minute) of the solution.

6.   – Solution Warning Light. 

Once the Solution Usage Timer is set, the light will come up. The light will 

flash when the solution needs changing.

7.      – Degas Status.    

Illuminated, the degas function is selected. 

 

Flashing, degassing is underway.

8. 

  – Heater Status. 

Press Heater button,   flashes, indicating the heater is turned on. Press Heater 

button again,   dims, indicating the heater is turned off.

9. 

  – Normal Cleaning Status.    

– Illuminated, normal cleaning is underway.

10. Working Status.  

Green - Ready (G): Normal working status, ready to use.

  Red - Overheat (R): Under overheat protection. 20 minutes or more of waiting time is needed for the light  

to change from red to green. Work can resume afterwards.

11.  Function Button. 

Press function button, 

 

illuminates, indicating Degas function is selected. Press On/

Off button to start degassing. 

 

will flash for 2 minutes, then the unit will return to the normal cleaning 

function. Pressing Function button before it ends will stop degassing. If additional degassing is needed 

after it ends, then press Function button again.

Degas:

 When cleaning heavily soiled or greasy items or silver, copper or brass items, chemical 

solutions need to be added into the water. The solution may form many small droplets and take a 

long time to dissolve in the water. Newly added water may generate many air bubbles on the tank 

walls. These will reduce the cleaning effect in the beginning phase of ultrasonic cleaning. Turning 

on the degas function will dissipate the droplets and the air bubbles, usually in 90 seconds, and 

improve cleaning efficiency.

12. Temperature Set Button. 

5 set temperatures can be selected. Press Temp button to select the temperature 

in the following sequence:

           40°C or 104°F   45°C or 113°F   50°C or 122°F   55°C or 131°F   60°C or 140°F 

11

CONTROL PANEL AND OPERATIONS

Summary of Contents for ULTRA 8060

Page 1: ...ion Colour LED display Clear display with 1 to 30 minute full range timer temperature settings and operation status Cooling fan Ensures prolonged operation Improves heat dissipation and beneficial for...

Page 2: ...e the device Warnings should be observed carefully Please follow the manual for operations TABLE OF CONTENTS Safety Precautions 4 5 Items Not Suitable for Ultrasonic Cleaning 5 Applications 6 7 8 Samp...

Page 3: ...perate the device unattended Follow the manual to operate the device Do not use components unapproved by the manufacturer When removing the power cord from the socket grab the power plug not the cord...

Page 4: ...unplug grasp the plug not the cord Unplug from outlet when not in use and before servicing or cleaning To reduce the risk of electrical shock do not put the appliance in water or other liquid Do not p...

Page 5: ...Using an ultrasonic cleaner and tap water can easily remove the debris 3 Biology Chemical Laboratories Labs can use ultrasonic cleaners to clean test tubes and other glass or metal containers to remov...

Page 6: ...raditional methods 9 Special Education Institutes Kindergartens Speech therapy tools or small toys that are reused need to be cleaned to prevent the growth and spread of bacteria Ultrasonic cleaning c...

Page 7: ...watch bands shavers or razors Ultrasonic cleaning can clean the debris in the crevices It is quick and convenient This model has a large tank When cleaning small items the Indirect Cleaning method ca...

Page 8: ...gears valves tools fuel injectors etc BABY ITEMS Toys baby items speech therapy tools etc SILVER COPPER OR BRASS Silverware silver copper or brass decorations etc LAB ITEMS Test tubes beakers flasks...

Page 9: ...10 PRODUCT DETAIL A View Window B Lid C Stainless Steel Tank D Housing E Drainage Tap F Drainage Pipe Fitting G Vent H Power Switch I Power Socket J Control Panel Hose Power Cord Plastic Basket...

Page 10: ...ng the heater is turned off 9 Normal Cleaning Status Illuminated normal cleaning is underway 10 Working Status Green Ready G Normal working status ready to use Red Overheat R Under overheat protection...

Page 11: ...ch pressing reduces the solution set time by 20 minutes 17 Heater Button Pressing heater button flashes indicating the heater is turned on To cancel heating press heater button again dims indicating t...

Page 12: ...cleaning Ultrasonic waves will penetrate the container and clean the items Debris accumulated over a long period of time greasy or heavily soiled Suitable Locations metal processing and jewellery make...

Page 13: ...ating the heater is turned off 4 Press h min button to set solution usage time Each pressing increases the time by 20 minutes Press button to reduce the time by 20 minutes each time Common time is or...

Page 14: ...re 5 10 or 15 minutes Prolonged cleaning time may result in a Loosening of the screws if used b Increasing pre existing cracks c Peeling of coating which was already separated Press On Off button to s...

Page 15: ...d up the mixing and to use less solution use degas function Press TIME button to set the timer to 10 minutes then press Function button illuminates Press On Off to start degassing It changes over to n...

Page 16: ...approximately 15 minutes respectively to ensure safety The unit will be disabled until it is repaired Do not run the unit for extended time or continuously The unit is designed with overheat protecti...

Page 17: ...roof and non porous Office equipment Printer heads printer cartridges fountain pen nibs wax or rubber stamps etc Tableware Cutlery Wood or bone handled tableware cutlery should not be immersed Only al...

Page 18: ...Fluid 1500 ml Tank Size 25 0 x 17 4 x 7 8 cm Power Supply 150 W AC 220 240V 50 60Hz Digital Timer Settings 1 to 30 minute full range timer Drainage Drainage valve Ultrasonic Frequency 36 000 Hz Tank...

Page 19: ...g your unit please call our Returns Department on 44 0 1258 822516 for a RMA Returns Materials Authorisation number Please return your unit in its original packaging along with a covering letter stati...