Signal Handling
TM-6740GE Software
4.4 Pulse Generators
The TM-6740GE camera has four independently programmable pulse generators. These generators can
run as either periodic or triggered. If you choose to run the pulse generators as triggered, they can be
triggered on either levels or signal edges. These generators can be tied to the camera inputs (camera-
control lines). For example, you can set pulse generator 0 in the Pulse Generator tabbed dialog box to
the following values:
Delay = 60,000
Width = 6,000
Granularity = 250
Now check the Periodic option and change the camera settings to Async 9. This will trigger the camera,
based on the pulse width set in the Pulse Generator page.
Be careful with the pulse generator’s GPIO input and output polarity. If the delay and pulse-width
duration are switched , the output polarity must be negated in the GPIO lookup table.
The pulse generators are configured in the “Pulse Generator” section in the Device Features tab of the
Advanced Configuration window as shown in Figure 23.
FIGURE 23.
Pulse Generator Page