Item
Setting value /
selectable range
Description
LUTMode
LUT
Use LUT.
LUTSelector* Red, Green, Blue
Select the LUT channel to control.
LUTIndex
0 ~ 256
Select the LUT index to configure. Indexes represent the
possible pixel values captured on the sensor, from the
lowest value (Index 0) to the highest (Index 256). For
example, Index 0 represents a full black pixel and Index
256 represents a full white pixel.
LUTValue
0 ~ 4095
Set the LUT output value for the selected index.
Lookup Table
(
LUT
)
The LUT function is used to generate a non-linear mapping between signal values
captured on the sensor and those that are output from the camera.
You can specify the output curve using 257 setting points (indexes).
■
To use the LUT function
Configure the settings as follows.
■
LUT Value
LUT values range from 0 at the lowest to 4095 at the highest. Linear interpolation is
used to calculate LUT values between the index points.
Index0 Index1 Index2
LUTValue[0]
LUTValue[1]
LUTValue[2]
Index256
LUTValue[256]
0
4095
Values between points are determined
using the linear interpolation values of
data to the left and right.
SW-8000T-10GE/SW-8000T-SFP
— 32 —
Summary of Contents for SW-8000T-10GE
Page 8: ...Parts Identification SW 8000T 10GE SW 8000T SFP 8 SW 8000T 10GE SW 8000T SFP ...
Page 63: ...Spectral Response SW 8000T 10GE SW 8000T SFP 63 Wave length nm Relative Response ...
Page 65: ...M52 mount SW 8000T 10GE M52 Dimensional tolerance 0 3mm Unit mm SW 8000T 10GE SW 8000T SFP 65 ...
Page 66: ...F mount SW 8000T SFP F SW 8000T 10GE SW 8000T SFP Dimensional tolerance 0 3mm Unit mm 66 ...
Page 67: ...M52 mount SW 8000T SFP M52 SW 8000T 10GE SW 8000T SFP Dimensional tolerance 0 3mm Unit mm 67 ...