SW-4010Q-MCL-M52 User Manual (Tentative)
Setting List
- 83 -
CounterAndTimerControl
Configure counter settings.
Note:
This camera only supports the counter functions.
Related Topic:
Counter and Timer Control Function
CounterAndTimer
Control Item
Setting
Range
Default
Value
Description
CounterSelector
0: Counter0
Select the counter.
0 - 7: Counter0 - 7
CounterEventSource
-
0: Off
Assign the Counter Event signal for which you want to read the
count value to a dedicated counter and read the value.
0: Off
1: Line Trigger (Counter0 only)
2: Exposure Start (Counter2 only)
3: Line Start (Counter1 only)
4: Line Transfer End (Counter3 only)
5: SWIR Line Trigger (Counter4 only)
6: SWIR Exposure Start (Counter6 only)
7: SWIR Line Start (Counter5 only)
8: SWIR Line Transfer End (Counter7 only)
CounterEventActivation
0:Rising Edge
-
Display the count timing. The setting value is fixed to Rising Edge.
CounterReset Source
-
-
Specify the source to reset the counter. This source triggers the
counter to reset.
0: Software
3: Line4 TTL In1
4: Line5 Opt In1
9: Line10 TTL In2
12: Line13 TTL In3
CounterResetActivation
-
-
Select the timing to reset the counter.
1: Rising Edge
2: Falling Edge
3: Level High
4: Level Low
CounterReset
-
-
Reset the counter.
Note:
Available only when
CounterResetSource
is set to
Software
.
CounterRefresh
-
-
Update the counter.
CounterValue
0 - 32bit max 0
Display the count value.