Setting range
Default value
Description
Configure counter settings.
(This camera only supports counter functions.)
ー
ー
Select the counter
[Setting range]
0:Counter0, 1:Counter1, 2:Counter2, 3:Counter3
CounterEventSource
ー
Off
Assign the counter event signal for which you want to read the count value
to a dedicated counter, and read the value.
[Setting range]
Counter0 0:Off, 1:FrameTrigger
Counter1 0:Off, 1:ExposureStart
Counter2 0:Off, 1:SensorReadOut
Counter3 0:Off, 1:FrameTransferEnd
CounterEventActivation
ー
ー
Set the count timing.
The setting value is fixed with the following data.
Counter0, Counter1, Counter2 : RisingEdge
Counter3 : FallingEdge
CounterReset
ー
ー
Reset the counter.
CounterValue
0〜65535
0
Display the count value.
CounterStatus
ー
ー
Display the counter status.
0: CounterIdle: Idle
1: CounterTriggerWait
2: CounterActive: Counting
3: CounterCompleted:Complete counting
4: CounterOverflow: Count value exceeded the maximum valule.
Configure user settings.
0: Default,
1: UserSet1,
2: UserSet2,
3: UserSet3
Default
Select the user settings.
UserSetLoad
ー
ー
Load user settings.
(If 0 is specified, the factory default setting is read.)
UserSetSave
ー
ー
Save the current setting values as user settings.
(If 0 is specified, UserSetSave is invalid.)
i) CounterAndTimerControl
j) UserSetControl
Item
CounterSelector
UserSetSelector
—
5
7
—
SP-45000M-CXP4/SP-45000C-CXP4