— 31 —
SP-12000M-CXP4 / SP-12000C-CXP4
Scanning range
Shortest period trigger
Full
5.275 ms
ROI 2/3
3.351 ms
ROI 1/2
2.534 ms
ROI 1/4
1.296 ms
ROI 1/8
0.885 ms
* SP-12000M-CXP4 only
t4
t1
t2
t3
Trigger
CMOS exposure
Exposure active
FVAL
Exposure duration
t1
t2
t3
t4
10 μs (8-bit), 15 μs (10-bit)
(minimum)
4.0 μ to 4.0 μ + 1L
0.6 μ to 0.6 μ + 1L
14L to 15L
Trigger overlap: Off
Sensor
Exposure
EEN
FVAL
A1
B
C
D1
Trigger
Valid data Period
(= Height x Line Period)
Next trigger start prohibited period
Next trigger input
allowed period
Trigger overlap: Readout
Sensor
Exposure
EEN
FVAL
A2
B
F
D2
Trigger
E
Next trigger start
prohibited period
Next trigger input
allowed period
Valid data Period
(= Height x Line Period)
Next trigger start allowed period
Next trigger end prohibited period